6 floors · 60 apartments · 53,000 sq ft · built 1927 · class D1 · owner of record: 1254 S Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 50 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 50 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 66 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 53,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 171 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 171 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 294 days | Registered through 2027-09-01 |
| Energy audit and retro-commissioning (2033) Likely applies Local Law 87 · Calendar year 2033 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2453). Agency page | Dec 31, 2033 in 2607 days | Next due 2033 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-22 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 8, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.AT SOUTH ELEVATION EXPOSURE #4(COURTYARD)OBSERVED DEFECTIVE STUCCO AT 7TH FLOOR WESTERN CORNER.OBSERVED CRACKED STUCCO & SPALLED WINDOW WILL AT 5TH #35647577J | Sep 9, 2022 IN VIOLATION | $0 |
| Aug 30, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.AS NOTED:EXP #1 SPALLED BRICKS DAMANAGED SINDOW SILLS,OPEN MORTAR JOINTS,STEP CRACKING,FAILED POTALES,CRACKED BRICKS,RUSTED FIRE ESCAPE,OBJECTS ON #35548861N | Jul 29, 2022 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #08652 | DOB VIOLATION - ACTIVE |
| May 11, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00162 | DOB VIOLATION - ACTIVE |
| Feb 9, 2022 | CONSTRUCTION PARTIAL VACATE ORDER. OBSERVED ON 02-08-2022 BY FACADE INSPECTOR THERE A DEFECTIVE STUCCO AT TOP WESTERN CORNER AT COURTYARD(EXP #4 #LLFA01MH | DOB VIOLATION - ACTIVE |
| Feb 8, 2022 | CONSTRUCTION EMERGENCY WORK ORDER-DUE TO DEFECTIVE STUCCO AT SOUTH ELEVATION, EXP #4. REMEDY: IMMED REPAIR/REPLACE DEFECTIVE STUCCO AT SOUTH ELEVATION EXP #4 AND PROVIDE SSAFETY MEASURES #LLFA01MH | DOB VIOLATION - ACTIVE |
| Sep 22, 2021 | ELEVATOR #9028/707614 | DOB VIOLATION - ACTIVE |
| Dec 31, 2013 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013 #00990 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| May 11, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 30, 2019 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019 | Active |
| Dec 31, 2013 | Facades FISPNRF FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 21, 2026 | B | Apt 3F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE REFRIGERATOR UPPER AND LOWER GASKET SEAL IN THE KITCHEN LOCATED AT APT 3F, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 26, 2026 |
| Aug 10, 2026 | A | Apt 6D · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE RISER AND RADIATOR AT SOUTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH | Nov 13, 2026 |
| Aug 10, 2026 | B | Apt 6D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQFT AT NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH | Sep 14, 2026 |
| Jul 15, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR AT NORTH SECTION AT PUBLIC HALL, 3rd STORY | Jul 29, 2026 |
| Jul 1, 2026 | B | Apt 3F · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN (10) SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 3F, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Aug 5, 2026 |
| Jun 29, 2026 | C | Apt 6D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' | Jul 25, 2026 |
| Jun 17, 2026 | C | Apt 1E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''CENTER'' | Jul 13, 2026 |
| Jun 17, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR AT PUBLIC HALL, 2nd STORY | Jul 1, 2026 |
| Jun 17, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR AT PUBLIC HALL, 5th STORY | Jul 1, 2026 |
| Jun 17, 2026 | C | Apt 1E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''CENTER'' | Jul 13, 2026 |
| Nov 7, 2025 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR AT NORTH AT PUBLIC HALL, 3rd STORY | Nov 21, 2025 |
| Oct 11, 2024 | C | Apt 2E5FLO · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CHIPPED AND LIFTING VINYL FLOOR TILES IN THE 1st ROOM FROM NORTH LOCATED AT APT 2E5FLO, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''1-5'', AT NORTH | Oct 17, 2024 |
| Jun 12, 2024 | B | Apt 8F · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROXIMATELY 4 SQ.FT IN THE BATHROOM LOCATED AT APT 8F, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16670363 ISSUED 12-FEB-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2 | Jul 17, 2024 |
| Feb 13, 2024 | A | Apt 10C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILE IN THE KITCHEN LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' | May 18, 2024 |
| Feb 13, 2024 | A | Apt 10C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' | May 18, 2024 |
| Jan 2, 2024 | B | Apt 10C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 6, 2024 |
| Jan 2, 2024 | A | Apt 10C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Apr 6, 2024 |
| Dec 15, 2023 | B | Apt 6F · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH | Jan 19, 2024 |
| Nov 21, 2023 | C | Apt 2A · § 27-2056.7 ADM CODE: CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES. | Nov 25, 2023 |
| Nov 21, 2023 | C | Apt 2A · § 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS. | Nov 25, 2023 |
| Oct 17, 2023 | C | Apt 4D · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 1; WG TO REPAIR = 0; IN THE 1st ROOM FROM NORTH LOCATED AT APT 4D, 4th STORY, 1st | Nov 12, 2023 |
| Sep 11, 2023 | B | Apt 8F · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX.1.SQ.FT. AT CEILING IN THE BATHROOM LOCATED AT APT 8F, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 15973426 ISSUED 10-MAY-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a | Oct 16, 2023 |
| Oct 30, 2019 | C | Apt 4D · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 4D, 4th STORY, 1st APA | Nov 27, 2019 |
| Oct 15, 2019 | C | Apt 10F · § 27-2056.7 ADM CODE -CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER IN THE ENTIRE APARTMENT LOCATED AT APT 10F, 8th STORY | Oct 21, 2019 |
| Jun 7, 2018 | A | Apt 8B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Sep 10, 2018 |
| Jun 7, 2018 | A | Apt 8B · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Sep 10, 2018 |
| Jun 6, 2018 | A | Apt 8B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Sep 9, 2018 |
| Sep 7, 2017 | B | Apt 8B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR ( BUCKLED ) IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Oct 12, 2017 |
| Sep 7, 2017 | B | Apt 8B · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Oct 12, 2017 |
| Sep 7, 2017 | B | Apt 8B · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). ADDITIONAL 1 NEEDED LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Oct 12, 2017 |
| Sep 7, 2017 | B | Apt 8B · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Oct 12, 2017 |
| Sep 7, 2017 | B | Apt 8B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Oct 12, 2017 |
| Sep 7, 2017 | B | Apt 8B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Oct 12, 2017 |
| Sep 7, 2017 | B | Apt 8B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Oct 12, 2017 |
| Sep 7, 2017 | B | Apt 8B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE 3rd ROOM FROM EAST LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Oct 12, 2017 |
| Sep 7, 2017 | B | Apt 8B · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR ADDITIONAL 1 NEEDED LOCATED AT APT 8B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Oct 12, 2017 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Sep 21, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE REFRIGERATOR UPPER AND LOWER GASKET SEAL IN THE KITCHEN LOCATED AT APT 3F, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 10, 2026 | HPD A | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE RISER AND RADIATOR AT SOUTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH | Open |
| Aug 10, 2026 | HPD B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQFT AT NORTH WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH | Open |
| Aug 10, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT BUILDING ENTRANCE , 1st STORY | Closed |
| Jul 27, 2026 | HPD B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ. FT. AT CEILING IN THE BATHROOM LOCATED AT APT 6D, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18994923 ISSUED 10-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-201 | Closed |
| Jul 15, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' | Closed |
| Jul 15, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT SWITCH AT EAST WALL IN THE BATHROOM LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' | Closed |
| Jul 15, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH WEST WALL IN THE BATHROOM LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' | Closed |
| Jul 15, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' | Closed |
| Jul 15, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR AT NORTH SECTION AT PUBLIC HALL, 3rd STORY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 11, 2026, 5:30 PM ET. BBL 2024530045.