Bronx · Block 4526 · Lot 1 · 10469

1251 Allerton Avenue

3 floors · 98,884 sq ft · built 1952 · class W1 · owner of record: Nyc Department Of Parks And Recreation

22open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
57dto Energy audit and retro-commissioning (2026)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 57 days
Keep the report on file (not filed with DOB)
Energy audit and retro-commissioning (2026) Likely applies
Local Law 87 · Calendar year 2026
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 4526). Agency page

Dec 31, 2026
in 57 days
Due this year
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2022-08-29 (Accepted). Agency page

Dec 31, 2026
in 57 days
2 of 2 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 98,884 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 178 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 178 days
Annual filing
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 422 days
Next cycle year 2027

Open violations

ECB / OATH (17)
IssuedViolationHearingBalance
Apr 17, 2026Construction CLASS - 2
REISSUE#35720674J FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT CELLAR NEAR SPRINKLER CONTROL VALUE ROOM & FAN ROOM THERE IS OLD DESK,CHAIRS & EXCESSIVE AMOUNT OF BOXES STONED IN AREAS.REM:REMO
#35732486K
May 29, 2026
POP/IN-VIO
$0
Apr 17, 2026Construction CLASS - 2
REISSUE#35720737H FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:CLASSROOM DOORS DO NOT SELF-CLOSE PROPERLY AT 3RD FLR RM#310,308,306,304,303,302,305,307,315,316,317,319,320,320A,322,325.2ND FLOOR
#35732485Z
May 29, 2026
POP/IN-VIO
$0
Apr 17, 2026Construction CLASS - 2
REISSUE#35720673H EXIT DOOR NOT SELF-CLOSING.NOTED:EXTERIOR DOORS DO NOT SELF-CLOSE PROPERLY AT 1ST FLR-EXIT#5,BASEMENT DELIVERY DOOR,& EXITDOOR#B24.REM:REPAIR/REPLACE DOOR.
#35732487M
May 29, 2026
POP/IN-VIO
$0
Jun 26, 2025Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING PROPERLY AT THE TIME OF INSPECTION AT THE TIME OF INSPECTION OBSERVED AND NOTED AT 1ST FL. EXIT #5 BASEMENT DELIVERY DOOR, AT BASEMENT LEVEL ROOM NO B24 ONE EXIT DOOR NOT SELF-CLOSING
#35720673H
Aug 29, 2025
POP/IN-VIO
$0
Jun 26, 2025Construction CLASS - 2
REISSUE #35684990X DATE OF ISSUE: 10-01-2024. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED DIFFERENT CLASS ROOM ALL DOOR CLOSURE/HARDWARE NOT IN OPERATION
#35720737H
Aug 29, 2025
POP/IN-VIO
$0
Jun 26, 2025Construction CLASS - 2
REISSUE #35684991H DATE OF ISSUE: 10-01-2024. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED AT CELLAR LEVEL NEAR SPRINKLER CONTROL VALVE EXCESSIVE AMOUNTS O
#35720674J
Aug 29, 2025
POP/IN-VIO
$0
Oct 1, 2024Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT CELLARLEVEL BY SPRINKLER CONTROL VALVE, EXCESSIVE AMOUNTS OF COMBUSTIBLE STORAGE ITEMS. INCLUDES SUPPLIES, FURNITURE, CARDBOARD BOXES AND MISC. MA
#35684991H
Nov 1, 2024
POP/IN-VIO
$0
Oct 1, 2024Construction CLASS - 2
REISSUE #35676308Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANENR. NOTED SEVERAL CLASSROOM DOORS THROUGHOUT THE SCHOOL ARE NOT SELF-CLOSING PROPERLY DUE TO DEFECTIVE HARDWARE. ADDITIONALLY CORRIDOR SMOK
#35684990X
Nov 1, 2024
POP/IN-VIO
$0
Nov 6, 2023Unknown CLASS - 1
I OBSERVED INSTALLATION OF PARALLEL FEEDER CONDUCTORS WITH DIFFERENT SIZE WIRE AND INSULATION IN LOAD SIZE AFTER CTS OF BOTH SERVICE DISCONNECT SWITCHES FEEDING DISTRIBUTION PANELS WORK WITHOUT PERMIT ON FILE.,
#39098904Y
Nov 25, 2023
POP/IN-VIO
$0
Jul 5, 2023Construction CLASS - 2
REISSUE #35665127L DATE OF ISSUE:07.22.2022 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT THE TIME OF INSPECTION OBSERVED VARIOUS LOCATIONS THROUGHOUT CLOSING DUE TO MISSING CLASS ROOM DOORS NOT SELF
#35676308Y
Nov 3, 2023
POP/IN-VIO
$0
Jul 5, 2023Construction CLASS - 2
REISSUE #35665126J DATE OF ISSUE:07.22.2022 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AT VARIOUS LOCATIONS THROUGHOUT CELLAR LEVEL OBSERVED EXCESSIVE STORAGE OF C
#35676309X
Nov 3, 2023
POP/IN-VIO
$0
Apr 11, 2023Unknown CLASS - 1
AT THE TIME OF MY INSPECTION. I OBSERVED OUTSIDE OF THE SCHOOL A TEMPORARY BOILER. SUB FEEDER, SUB PANEL, BRANCH CIRCUITS WIRING,, OBTAIN PERMIT; OBTAIN PERMIT.
#39083560H
May 1, 2023
POP/IN-VIO
$0
Jul 22, 2022Construction CLASS - 2
RE-ISSUE #35452223M-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT VARIOUS LOCATIONS THROUGHOUT ENTIRE BUILDING(SCHOOL)OBSERVED CLASSROOM DOOR NOT SELF CLOSING DUE TO MISSING/DEFECTIVE HARDWARD.
#35665127L
Oct 21, 2022
POP/IN-VIO
$0
Jul 22, 2022Construction CLASS - 2
RE-ISSUE #35591959P-FAILURE TO MAINTAIN BUILDINGIN CODE COMPLIANT MANNER.NOTED:AT VARIOUS LOCATIONS THROUGHOUT ENTIRE BUILDING(SCHOOL)OBSERVED EXCESSIVE AMOUNT OF COMBUSTIBLE MATERIALS STORED IN GAS METER ROOM
#35665126J
Oct 21, 2022
POP/IN-VIO
$0
Sep 20, 2021Construction CLASS - 2
RE-ISSUE #35500808L FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION OBSERVED EXCESSIVE STORAGE OF COMBUSTIBLE MATERIALS EG SCHOOL SUPPLIES, BOXES, PAPERS, WOODEN DESK PART,PLASTIC CH
#35591959P
Dec 17, 2021
POP/IN-VIO
$0
Aug 25, 2021Construction CLASS - 2
RE-ISSUED #35500807J.FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:BUILDING'S ENTIRE CLASSROOM DOORS ARE NOT SELF CLOSING DUE TO MISSING/DEFECTIVE HARDWARE.REMEDY:REPAIR AND/OR REPLACE.
#35452223M
Dec 17, 2021
POP/IN-VIO
$0
Jun 17, 2020Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED CLASSROOM DOORS 3RD FLOOR ROOMS 324,325,322,320A,319,317,316,315,313,310,307,308,305,306,303,304,302,301,2ND FLOOR ROOMS 204,203,206,205,208,
#35500807J
Oct 2, 2020
POP/IN-VIO
$0
DOB (2)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#07170
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#07169
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 11)
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 4, 2026, 2:02 AM ET. BBL 2045260001.

Look up another building