70 floors · 2,122,138 sq ft · built 1937 · class RC · owner of record: Rockefeller Center Properties (Rcp)
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 42 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | Feb 21, 2027 in 94 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 2,122,138 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 163 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 163 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1138 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1265). Agency page | Dec 31, 2035 in 3329 days | Next due 2035 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 7, 2026 | Elevators CLASS - 2 CLASS 2 ITEM: ESCALATOR OBSERVED WITH LOOSE BED SKIRTS, BROKEN TEETH ON STEPS, AND DAMAGED/MISSING TEETH AT THE TOP LANDING. ESCALATOR SAFETY COMPONENTS ARE NOT MAINTAINED IN PROPER OPERATING CONDITION. VIOLATI #39207312K | Dec 24, 2026 PENDING | $625 |
| Nov 1, 2021 | Construction CLASS - 2 27-929.1;A.C.#27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BLDG 100 FT OR MORE #37022728K | Aug 4, 2022 IN VIOLATION | $0 |
| Mar 30, 2021 | Construction CLASS - 2 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE 100FT OR MORE IN HEIGHT IN EXIS #37020795L | Jul 1, 2021 IN VIOLATION | $0 |
| Sep 29, 2020 | Construction CLASS - 2 SEC. 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OFAUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BLDG 100 FEET OR MORE IN HEIG #37020345Y | Dec 31, 2020 STIPULATION/IN-VIO | $0 |
| Jan 12, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. USE PROHIBITED DOOR/HARDWARE PER BC 1008.1.8. NOED IN THE COMMERCIAL STORE AT THE ENTRANCE DOOR AT 49 STREET OBSERVED ILLEGAL LOCKING DEVICES/MANUAL LOCK #35373242M | Mar 7, 2019 IN VIOLATION | $0 |
| Jun 28, 2018 | Construction CLASS - 2 FAILURE TO PROVIDE APPROVED ACCEPT PLANS AT TPA SITE. AT THE TIME OF MY INSPECTION TEMPORARY PLACE OF ASSEMBLY WAS IN PROGRESS. DURING MY INSPECTION I REQUESTED APPROVED PLANS NONE WAS PROVIDED. STOP ALL TPA AC #35333052P | Oct 18, 2018 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 5, 2021 | ELEVATOR #9027/709221 | DOB VIOLATION - ACTIVE |
| Sep 3, 2019 | SPRINKLER FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019 #NRF01091 | DOB VIOLATION - ACTIVE |
| May 31, 2018 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 #01813 | DOB VIOLATION - ACTIVE |
| Dec 27, 2010 | ELEVATOR #9027/368213 | DOB VIOLATION - ACTIVE |
| Sep 30, 2010 | ELEVATOR #9028/351992 | DOB VIOLATION - ACTIVE |
| Sep 3, 2010 | ELEVATOR #351997/9028 | DOB VIOLATION - ACTIVE |
| Sep 1, 2010 | ELEVATOR #351996/9028 | DOB VIOLATION - ACTIVE |
| Aug 31, 2010 | ELEVATOR #351994/9028 | DOB VIOLATION - ACTIVE |
| Aug 31, 2010 | ELEVATOR #351993/9028 | DOB VIOLATION - ACTIVE |
| Aug 31, 2010 | ELEVATOR #351995/9028 | DOB VIOLATION - ACTIVE |
| Aug 31, 2010 | ELEVATOR #9028/351995 | DOB VIOLATION - ACTIVE |
| Aug 30, 2010 | ELEVATOR #351988/9028 | DOB VIOLATION - ACTIVE |
| Aug 30, 2010 | ELEVATOR #351998/9028 | DOB VIOLATION - ACTIVE |
| Aug 30, 2010 | ELEVATOR #351992/9028 | DOB VIOLATION - ACTIVE |
| Aug 30, 2010 | ELEVATOR #351991/9028 | DOB VIOLATION - ACTIVE |
| Aug 30, 2010 | ELEVATOR #351990/9028 | DOB VIOLATION - ACTIVE |
| Aug 30, 2010 | ELEVATOR #351989/9028 | DOB VIOLATION - ACTIVE |
| Jan 8, 2008 | ELEVATOR #9011/231740 | DOB VIOLATION - ACTIVE |
| Aug 22, 2005 | ELEVATOR #90111140302 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 5) | Active |
| Aug 29, 2025 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Report | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Report | Active |
| Sep 3, 2019 | Sprinklers FTF-SP-FINAL | Active |
| Apr 5, 2019 | Elevators EVCAT1 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Dec 24, 2019 | B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AT 1st BASEMENT FROM NORTH | Jan 28, 2020 |
| Dec 24, 2019 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT 1st BASEMENT FROM NORTH | Mar 28, 2020 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 7, 2026 | ECB | Elevators: CLASS 2 ITEM: ESCALATOR OBSERVED WITH LOOSE BED SKIRTS, BROKEN TEETH ON STEPS, AND DAMAGED/MISSING TEETH AT THE TOP LANDING. ESCALATOR SAFETY COMPONENTS ARE NOT MAINTAINED IN PROPER OPERATING CONDITION. VIOLATI | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 19, 2026, 2:38 PM ET. BBL 1012657501.