18 floors · 311 apartments · 260,640 sq ft · built 2025 · class D6 · owner of record: Maspeth Park Housing Development Fund Co Rporation
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual boiler inspection (9 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-16 (Accepted). Agency page | Dec 31, 2026 in 65 days | 8 of 9 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $996,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 117 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 260,640 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 796 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2885). Agency page | Dec 31, 2035 in 3352 days | Next due 2035 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 28, 2026 | Construction CLASS - 2 MONORAIL SUSPENDED SCAFFOLD SYSTEM INSTALLED CONTRARY TO PLANS-ATTACHMENT OF BEAMS TO CONCRETE SLAB-USING CHOKE/SLING LINES-AS PER PLAN 5/16" WIRE ROPE WITH J-BOLTS AT TOP AND BOTTOM ,TIMBLE,SHACKLE TO BE USED, #39557629Z | Oct 14, 2026 IN VIOLATION | $1,250 |
| Jul 28, 2026 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION -OBSERVED OUTRIGGER BEAM SUSPENDED SCAFFOLD INSTALLED AT EXP#2(ROOF) WITH TIEBACK INSTALLED TO ANGLE ANCHORAGE SYSTEM ON CONCRETE WALL-NO PULL TEST PERFORMED/PROVIDED AS REQUIRED-ST #39557631H | Oct 14, 2026 IN VIOLATION | $1,250 |
| Jul 28, 2026 | Cranes and Derricks CLASS - 2 OBSERVED INSTALLED FIXED MONORAIL MULTIPOINT SUSPENDED SCAFFOLD ON SITE-UPON CHECKING DOB RECORDS-NO NOTIFICATION FOR FIXED/NON ADJUSTABLE SCAFFOLD PROVIDED TO DOB AS REQUIRED(ONLY COUNTERWEIGHTS/ADJUSTABLE SCA #39557630X | Oct 14, 2026 IN VIOLATION | $2,500 |
| Jul 27, 2026 | Construction CLASS - 2 RESPONDING TO AN INCIDENT, WHERE WORKER ISTVAN BENEDEK RESULTED IN INJURY HIS RIGHT LEG WHEN TESTING MATERIAL HOIST, INSPECTION REVEALED. CONTRACTOR FAILURE TO SAFEGUARD, NO MEANS AND METHODS HOW TO HANDLE MATE #39557113H | May 10, 2027 PENDING | $5,000 |
| Jul 27, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED: PRE-CAST (5' BY 5' APPROX.) PANEL INSTALLATION IN PROGRESS, USING CHAIN HOIST NOT SHOWING ON DRAWINGS. NO BLOW-UP DRAWINGS SECTION AND DETAILS FOR MANUAL RAIL SYSTEM. CREATING UN #39557114J | May 10, 2027 | $2,500 |
| Jul 16, 2026 | Construction CLASS - 1 18-STORY NEW BUILDING, I OBSERVED FACADE WORK AT EXPOSURES 1 AND 2 USING A SUSPENDED SCAFFOLD WHILE WORKERS WERE BELOW WITHOUT OVERHEAD PROTECTION OR A CONTROLLED ACCESS ZONE. THIS CREATED A HAZARDOUS CONDITION #39556722Z | Apr 6, 2027 | $10,000 |
| Apr 29, 2026 | Unknown CLASS - 1 AT THE TIME OF MY INSPECTION OF A 18 STORY NEW BUILDING,RESPONDING TO AN INCIDENT REPORTED BY LOCAL 79 THAT WORKER GOT INJURED. I OBSERVED SUSPENDED SCAFFOLD INSTALLED AT EXPOSURE #1,2,3,4,UPON SCANNING OF 1 SC #39553639Y | Jan 28, 2027 | $5,000 |
| Apr 29, 2026 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION, RESPONDING TO AN INCIDENT REPORTED BY LOCAL 79 THAT WORKER GOT INJURED. INVESTIGATION REVEAL THAT INCIDENT OCCURRED FROM 04-22-2026. INJURED WORKER WAS WAITING FOR THE ELEVATOR AT #39553638M | Jan 28, 2027 | $5,000 |
| May 16, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE, 18 STORY NEW BUILDING COMPLETED TO BULKHEAD. OBSERVED AT FLOORS 17TH, 18TH #35693669Y | Mar 11, 2027 | $1,250 |
| May 16, 2025 | Construction CLASS - 1 BC 2104.5. FAILURE TO PROVIDE MASONRY CMU BLOCK WALL CONSTRUCTION BRACING ACCORDANCE WITH TMS 602/ACI 530.1 ASCE 6 SECTION 3.3E. AS NOTED ATTIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE 18 STORY NEW BUILDIN #35693667K | Mar 11, 2027 | $2,500 |
| Nov 9, 2021 | Construction CLASS - 2 NOTED: OBSERVED THROUGHOUT ENTIRE BUILDING AT EACH FLOOR MORE THAN 20 EXISTING EMERGENCY LIGHTS WERE NOT OPERATIONAL WHEN TESTED., REPAIR/REPLACE LIGHTING #39050848X | Nov 12, 2021 POP/IN-VIO | $0 |
| Nov 9, 2021 | Construction CLASS - 2 NOTED: OBSERVED THROUGHOUT CELLAR AT VARIOUS LOCATIONS, SPALLING AND MISSING CONCRETE EXPOSING RE-BARS AND STEEL BEAMS OF THE CEILING SLAB, ALSO COMPROMISING FIREPROOFING OF STEEL BEAMS., REPAIR AND/OR REPLACE #39050846M | Nov 12, 2021 POP/IN-VIO | $0 |
| Nov 9, 2021 | Construction CLASS - 2 NOTED: BUILDING ALTERED/CHANGED FROM A MEDICAL FACILITY AND NOW OCCUPIED AS A HOMELESS SHELTER CONTRARY TO CERTIFICATE OF OCCUPANCY #214644., OBTAIN A VALID C OF O OR DISCONTINUE ILLEGAL OCCUPANCY #39050847Y | Nov 12, 2021 POP/IN-VIO | $0 |
| Sep 28, 2021 | Construction CLASS - 1 WORK WITHOUT A PERMIT. #39048328J | Oct 15, 2021 POP/IN-VIO | $0 |
| Sep 28, 2021 | Boilers CLASS - 2 UNREGISTERED BOILER. #39048327H | Oct 15, 2021 POP/IN-VIO | $0 |
| Sep 23, 2021 | Elevators CLASS - 1 UPON INSPECTION DEVICE WAS FOUND OUT OF SERVICE. RESTORE TO SERVICE IMMEDIATELY AND CONTACT THE DOB AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INSPECTION. #39048032K | Oct 15, 2021 POP/IN-VIO | $0 |
| Sep 23, 2021 | Elevators CLASS - 1 UPON INSPECTION DEVICE WAS FOUND OUT OF SERVICE. RESTORE TO SERVICE IMMEDIATELY AND CONTACT DOB AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INSPECTION. #39048031Z | Oct 15, 2021 POP/IN-VIO | $0 |
| Mar 2, 2020 | Unknown CLASS - 1 I OBSERVED EXPOSED CURRENT CARRYING CONDUCTORS AND DANGEROUS WIRING METHODS OF EQUIPMENTS, WAS INSTALLED AT BASEMENT AND ROOF LOCATION. ENERGIZED WIRES PROTRUDING FROM RIDGED CONDUIT RUNNING HORIZONTAL ON PARAP #39019843L | Apr 8, 2020 POP/IN-VIO | $0 |
| Mar 2, 2020 | Construction CLASS - 2 FAILURE TO MAINTAIN THE BUILDING IN CODE COMPLIANT MANNER- OBSERVED AT THE ABOVE ADDRESS NO VENTILATION IN GAS METER ROOMS LOCATED THE BASEMENT/CELLAR., REPAIR AND/OR REPLACE #39018732Y | Mar 16, 2020 POP/IN-VIO | $0 |
| Mar 2, 2020 | Construction CLASS - 2 FAILURE TO MAINTAIN THE BUILDING IN CODE COMPLIANT MANNER- OBSERVED AT THE ABOVE ADDRESS SPRINKLER HEAD LOCATED ON THE 6 FLOOR STAIRWAY INSTALLED INCORRECTLY( SPRINKLER INSTALLED INTO THE CEILING)., REPAIR AND/ #39018731M | Mar 16, 2020 POP/IN-VIO | $0 |
| Aug 21, 2019 | Construction CLASS - 2 I OBSERVED NO VENTILATION IN THE GAS METER ROOM LOCATED IN THE BASEMENT. , REPAIR AND/OR REPLACE #39008575K | Sep 5, 2019 POP/IN-VIO | $0 |
| May 1, 2019 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #353728542 ISSUED ON 11/20/18 AND TO FILE A CERT.OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.REM:COMPLY WITH COMMISSIONER'S #35398448Z | Oct 7, 2019 POP/IN-VIO | $0 |
| Mar 4, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: OBSERVEDTHROUGHOUT CELLAR, SPALLING CONCRETE OF CEILING SLAB THROUGHOUT CELLAREXPOSING RE-BARS, METAL LATHE AT AREAS THAT PCS HAVE FALLEN OFF.RMDY: #35383804Y | Jul 1, 2019 POP/IN-VIO | $0 |
| Mar 4, 2019 | Construction CLASS - 3 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. OBSERED ON 3/4/19 AT ABOVE ADDRESS CRACKED SIGHT GLASS ON 2 OUT OF 3 BOILERS. RMDY: REPAIR AND OR REPLACE. *PHOTOS TAKEN #35386215J | Jul 1, 2019 POP/IN-VIO | $0 |
| Mar 4, 2019 | Construction CLASS - 3 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED N 3/4/19 AT ABOVE ADDRESS ZIP SCREWS USED ON DRYER FL. RMDY: REPAIR AND REPLACE. *PHOTOS TAKEN. #35386213X | Jul 1, 2019 POP/IN-VIO | $0 |
| Mar 4, 2019 | Construction CLASS - 2 ALTERED/CHANGED BUILDING OCCUPIED W/O A VALID CERTIFICATE OF OCCUPANCYAS PER 28-118.3.1, 28-118.3.2. BUILDING ALTERED FROM A MEDICAL LABORA TORY INTO A HOMELSS SHELTER, COFO #214644 INDICATES PREMISE TO BE FOR #35383803M | Jul 1, 2019 POP/IN-VIO | $0 |
| Mar 1, 2019 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35372854Z ISSUED ON 01/20/2018, AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1RCNY 102-01 TEST STATION FOR SPRINKL #35395279N | Jul 1, 2019 POP/IN-VIO | $0 |
| Feb 13, 2019 | Elevators CLASS - 2 52BB12; 52,BB,12 RESHACKLE HOIST ROPES TAG EXPIRED. #38268262Y | Aug 5, 2019 POP/IN-VIO | $0 |
| Jan 11, 2019 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35372854Z ISSUED ON 11/20/18 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201 AND 1RCNY 102-01.NOTE:NO DOCUMENT FILE FOR #35391075N | Apr 15, 2019 DEFAULT | $0 |
| Nov 20, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.OBSERVED ON THE TOP FL NO PRESSURE GAUGE INSTALLED ON THE INSPECTOR TEST STATION FORTHE AUTOMATIC FIRE SPRINKLER SYSTEM AND IN STAIRWELL 4B A FIRE SPRINKL #35372854Z | Jan 28, 2019 POP/IN-VIO | $0 |
| Aug 15, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NO FIRE STOPPING PERBC 712.3;27-345.NOTED:OBSERVED AT CELLAR-GAS METER ROOM HAVE PIPES PENETRATING INTO ADJACENT ROOMS AND AREAS,HOLES/OPENINGS IN WALLS WITH NO #35347504Y | Nov 5, 2018 POP/IN-VIO | $0 |
| Aug 15, 2018 | Construction CLASS - 2 BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1;28-118.3.2.NOTED:C OF O #214644 STATES PREMISE TO BE FOR LABORATORIES,A MORGUE,AN AUTOPSY ROOM,MUSEUM,STERILIZING ROOM,LOCKER ROOMS N #35347506H | Nov 5, 2018 POP/IN-VIO | $0 |
| Aug 15, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:OBSERVED THROUGHOUT CELLAR,CONCRETE CEILING HAS SPALLING CONCRETE,MISSING CONCRETE AT VARIOUS LOCATIONS THROUGHOUT CELLAR EXPOSING RE-ENFORCEMENTS STE #35347505X | Nov 5, 2018 POP/IN-VIO | $0 |
| May 18, 2018 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #812642.REM:SUBMIT REQUIRED TECHNICAL REPORT. #37010194R | Sep 10, 2018 POP/IN-VIO | $0 |
| Mar 30, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED AT TOP OF STAIRWELL NO PRESSURE GAUGE INSTALLED ON THE INSPECTION TEST VALVE AND A FIVE SPRINKLER HEAD PAINTED IN STAIRWELL 412.PREVIOUS SUMMONS #3 #35325223K | Jul 2, 2018 POP/IN-VIO | $0 |
| Feb 16, 2018 | Elevators CLASS - 2 97##5 FAILURE TO MAINTAIN ELEVATOR RESPODENT FAILED TO ALLOW MANDATORY ANNUAL/ROUTINE INSPECTION BY THE DEPT OR APPROVED AGENCY PER 28-304.16.1 AND APPENDIX K OF THE BUILDING CODE. MULTIPLE ATTEMPTS TO GAIN #38261194J | Jul 16, 2018 POP/IN-VIO | $0 |
| Jan 17, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED ON 01/17/18 AT ABOVE ADDRESS PREVIOUSLY USED SPRINKLER HEADS MIXED IN WITH UNUSED SPRINKLER HEADS. ALSO, NO INSPECTOR'S TEST GAUGE OR VALVE ON UPP #35298014N | Apr 9, 2018 POP/IN-VIO | $0 |
| Jan 17, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED ON 01/17/18 AT THE ABOVE ADDRESS SPRINKLER HEADS THROUGHOUT BUILDING ARE TOO CLOSE TO THE LIGHT FIXTURES, OBSTRUCTING THE SPREAD OF WATER. REM: RE #35298013L | Apr 9, 2018 POP/IN-VIO | $0 |
| Dec 20, 2017 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED AT TOPOF STAIRWELL NO GAUGE INSTALLED AT THE INSPECTOR'S TEST AND A FIRE SPRINKLER HEAD PAINTED IN STAIRWELL 4B. PREVIOUS SUMMONS #35289862L #35311102R | Apr 9, 2018 POP/IN-VIO | $0 |
| Oct 11, 2017 | Elevators CLASS - 2 97##5.FAILURE TO MAINTAIN ELEVATOR DEVICE.RESPONDENT FAILED TO ALLOW MANDATORY ANNUAL/ROUTINE INSPECTION BY THE DEPARTMENT PER 28-304.6.1. &APPENDIX K OF BUILDING CODE.MULTIPLE ATTEMPT TO GAIN ACCESS TO PERFORM #38259566Z | Feb 5, 2018 POP/IN-VIO | $0 |
| Aug 15, 2017 | Construction CLASS - 2 BLDG OCCUPIED W/O A VALID C OF O AS PER 28-118.3.1 - 28-118.3.2. NOTED: C OF O #214644 ISSUED 9/7/1976, STATES PREMISE TO BE LABORATORIES, MORQUE, AUTOPSY ROOM, MUSEUM, STERILIZING, ANTMAL & LOCKER ROOMS - NOW #35287318Z | Dec 11, 2017 POP/IN-VIO | $0 |
| Aug 15, 2017 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED @ TOP OF STAIRWELL NO PRESSURE GAUGE INSTALLED ON INSPECTION'S TEST STATION AS IS REQUIRED. ALSO IN STAIRWELL 4B FIRE SPRINKLER HEAD IS PAINTED WHICH #35289858Z | Dec 11, 2017 POP/IN-VIO | $0 |
| Aug 15, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NO FIRE STOPPING PER BC712.3; 27-345. NOTED: OBSERVED @ CELLAR WITHIN BOTH GAS METER ROOMS PIPE PENETRATIONS WITH NO FIRE STOPPING PROVIDED @ VARIOUS LOCATIONS #35287320H | Dec 11, 2017 POP/IN-VIO | $0 |
| Aug 15, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: OBSERVED @ CELLAR SPALLING CEMENT THAT HAS FALLEN @ VARIOUS LOCATIONS FROM CEILINGEXPOSING REINFORCEMENT STEEL. REMEDY: REPAIR &/OR REPLACE. #35287319K | Dec 11, 2017 POP/IN-VIO | $0 |
| Mar 9, 2017 | Construction CLASS - 2 FAILURE TO PROVIDE POWER FOR EMERGENCY LIGHTING. NOTED: AT 2ND STORY CORRIDOR OUTSIDE ROOM 206 EMERGENCY EXIT LIGHT INOPERABLE/NUT LIGHTING UP. REMEDY: PROVIDE ADEQUATE POWER FOR EMERGENCY LIGHTING. #35229218X | May 8, 2017 POP/IN-VIO | $0 |
| Mar 9, 2017 | Plumbing CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. RE: INSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER P.C. 102.3; 27-902 MALLEABLE FITTINGS ON INSPECTORS TEST. ALSO INSPECTOR'S TEST DOESN'T HAVE A #35235136N | May 8, 2017 POP/IN-VIO | $0 |
| Aug 3, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG CODE COMPLIANT:LACK OF EMERGENCY LIGHTING PERBC1006.1; 27-542. NOTED: AT STAIRWAY "E", 4D,4A,3A INOPERATIVE EMERGENCY LIGHTING WITH BATTERY BACKUP. RMDY: COMPLY WITH CODE. #35200753Z | Sep 12, 2016 POP/IN-VIO | $0 |
| Mar 30, 2016 | Elevators CLASS - 2 05X10;17M07;18M07;28H11;59U15;64M07;70O02;67M07; 05-X-10 DOOR ZONE RESTRICTOR NOT WORKING. 17-M-07 HATCH MISSING GIB SHOES. 18-M-07 PROVIDE FIRE GIBS. 28-H-11 REPLACE WORN ROLLERS. 59-U-15 BRAKE MAINTENANCE TAG #38241796Z | May 16, 2016 POP/IN-VIO | $0 |
| Mar 30, 2016 | Elevators CLASS - 2 05E01;05X10;10H11;16M07;18M07;28H11;40Q13;59U15;64M07;70O02;67M07. 05-E-01 CAR DOOR ARE RUBBING. 05-X-10 DOOR RESTRICTOR NOT WORKING. 10-H-11 REPLACE DOOR GIBS. 16-M-07 GIB MISSING. 18-M-07 PROVIDE FIRE GIBS. #38241795R | May 16, 2016 POP/IN-VIO | $0 |
| May 3, 2013 | Elevators CLASS - 2 97**FAILURE TO MAINTAIN ELEVATOR DEVICE.RESPONDENT FAILED TO PROVIDE PROPER ACCESS IN ORDER THAT THE DEPT CAN PERFORM PERIODIC INSPECTIONS PER 28-304.6 AND APPENDIX K OF THE BLDG CODE.RESPONDENT FAILED TO PROV #38227090X | Jun 17, 2013 POP/IN-VIO | $0 |
| Jun 13, 2002 | Construction Non-Hazardous ALTERED BUILDING OCCUPIED WITHOUT VALID COFO TEMPORATY COFO# 300765900 ISSUED 1/30/02 HAS EXPIRED 4/30/02 REMEDY; OBTAIN VALID COFO. #34322583Y | Jul 29, 2002 WRITTEN OFF | $0 |
| Dec 5, 1996 | Construction Hazardous FAILURE TO MAINTAIN BUILDING DEFECTS ARE NO FIRE ALARM SYSTEM DEFECTIVE FIRE ALARM SYSTEM @ 1ST FKR OF MEN'S SHELTER OCCUPANCY OF MORE THAN 100 PERSONS AT TIME OF INSPECTION (BUILDING 1) REMEDY: RESTORE FIRE #34147289H | Mar 3, 1997 WRITTEN OFF | $0 |
| Jun 2, 1995 | Construction Hazardous FAILURE TO MAINTAIN THE INTERIOR FIRE ALARM SYSTEM:INOPERATIVE FIRE ALARM SYSTEM AT THE FIRST FLOOR AREA OF BLDG #1.REMEDY:IMEDIATELY PROVIDE A WORKING SIGNAL SYSTEM AS PER CODE. #34126196X | Aug 7, 1995 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2022 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 #01553 | DOB VIOLATION - ACTIVE |
| May 6, 2021 | ELEVATOR #9027/701199 | DOB VIOLATION - ACTIVE |
| Jul 21, 2020 | ELEVATOR #9027/685477 | DOB VIOLATION - ACTIVE |
| Apr 5, 2019 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR - FAILURE TO FILE CATEGORY 1 2017 INSPECTION/TEST #05170 | DOB VIOLATION - ACTIVE |
| Sep 15, 2017 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST #06118 | DOB VIOLATION - ACTIVE |
| Feb 6, 2017 | ELEVATOR #9027/596359 | DOB VIOLATION - ACTIVE |
| Dec 1, 2016 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2015 INSPECTION/TEST #04907 | DOB VIOLATION - ACTIVE |
| Jun 1, 2016 | NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST FAILURE TO PERFORM CATEGORY 5 INSPECTION #03262 | DOB VIOLATION - ACTIVE |
| Jun 10, 2015 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST #05036 | DOB VIOLATION - ACTIVE |
| Oct 31, 2014 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST #05783 | DOB VIOLATION - ACTIVE |
| Oct 31, 2014 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST #05782 | DOB VIOLATION - ACTIVE |
| Mar 31, 2014 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST #08600 | DOB VIOLATION - ACTIVE |
| Mar 31, 2014 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST #08601 | DOB VIOLATION - ACTIVE |
| Oct 1, 2012 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST #02919 | DOB VIOLATION - ACTIVE |
| Aug 13, 2010 | ELEVATOR #9027/348318 | DOB VIOLATION - ACTIVE |
| May 24, 2010 | ELEVATOR #9027/338260 | DOB VIOLATION - ACTIVE |
| Feb 27, 2009 | LOCAL LAW 10/81 - ELEVATOR #02452 | DOB VIOLATION - ACTIVE |
| Oct 21, 2008 | ELEVATOR #9011/281987 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Mar 21, 2008 | LOCAL LAW 10/81 - ELEVATOR #02840 | DOB VIOLATION - ACTIVE |
| Apr 2, 2007 | LOCAL LAW 10/81 - ELEVATOR #02832 | DOB VIOLATION - ACTIVE |
| Nov 28, 2006 | ELEVATOR #9011/182177 | DOB VIOLATION - ACTIVE |
| Oct 1, 2005 | LOCAL LAW 10/81 - ELEVATOR #03402 | DOB VIOLATION - ACTIVE |
| Nov 19, 2004 | LOCAL LAW 10/81 - ELEVATOR #02489 | DOB VIOLATION - ACTIVE |
| Apr 21, 2004 | LOCAL LAW 10/81 - ELEVATOR #02757 | DOB VIOLATION - ACTIVE |
| Mar 21, 2003 | LOCAL LAW 10/81 - ELEVATOR #02279 | DOB VIOLATION - ACTIVE |
| Feb 19, 2002 | LOCAL LAW 10/81 - ELEVATOR #02765 | DOB VIOLATION - ACTIVE |
| Mar 8, 2001 | LOCAL LAW 10/81 - ELEVATOR #02397 | DOB VIOLATION - ACTIVE |
| Mar 10, 2000 | LOCAL LAW 10/81 - ELEVATOR #02581 | DOB VIOLATION - ACTIVE |
| Jan 20, 1999 | LOCAL LAW 10/81 - ELEVATOR #02446 | DOB VIOLATION - ACTIVE |
| Jan 6, 1998 | LOCAL LAW 10/81 - ELEVATOR #02186 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #02967 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #02994 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #02968 | DOB VIOLATION - ACTIVE |
| Mar 8, 1996 | LOCAL LAW 10/81 - ELEVATOR #02459 | DOB VIOLATION - ACTIVE |
| Apr 17, 1995 | LOCAL LAW 10/81 - ELEVATOR #03092 | DOB VIOLATION - ACTIVE |
| May 31, 1994 | LOCAL LAW 10/81 - ELEVATOR #03677 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #19046 | DOB VIOLATION - ACTIVE |
| Jun 28, 1993 | LOCAL LAW 10/81 - ELEVATOR 1 #03240 | DOB VIOLATION - ACTIVE |
| Apr 7, 1992 | LOCAL LAW 10/81 - ELEVATOR 1 #03959 | DOB VIOLATION - ACTIVE |
| Apr 25, 1991 | LOCAL LAW 10/81 - ELEVATOR 1 #02527 | DOB VIOLATION - ACTIVE |
| Jun 29, 1990 | LOCAL LAW 10/81 - ELEVATOR 3 #03605 | DOB VIOLATION - ACTIVE |
| Jun 29, 1990 | LOCAL LAW 10/81 - ELEVATOR 1 #03606 | DOB VIOLATION - ACTIVE |
| Oct 12, 1989 | LOCAL LAW 10/81 - ELEVATOR 1 #04771 | DOB VIOLATION - ACTIVE |
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Jul 28, 2026 | ECB | Construction: MONORAIL SUSPENDED SCAFFOLD SYSTEM INSTALLED CONTRARY TO PLANS-ATTACHMENT OF BEAMS TO CONCRETE SLAB-USING CHOKE/SLING LINES-AS PER PLAN 5/16" WIRE ROPE WITH J-BOLTS AT TOP AND BOTTOM ,TIMBLE,SHACKLE TO BE USED, | Open |
| Jul 28, 2026 | ECB | Construction: AT TIME OF INSPECTION, DURING A DEPARTMENT-ISSUED HIGH WIND ADVISORY, OBSERVED A SUSPENDED SCAFFOLD PLATFORM LANDED ON THE EDGE OF THE SEVENTH-FLOOR BALCONY WITHOUT PROTECTION AND NOT SECURED AS REQUIRED BY THE | Closed |
| Jul 28, 2026 | ECB | Construction: AT THE TIME OF MY INSPECTION -OBSERVED OUTRIGGER BEAM SUSPENDED SCAFFOLD INSTALLED AT EXP#2(ROOF) WITH TIEBACK INSTALLED TO ANGLE ANCHORAGE SYSTEM ON CONCRETE WALL-NO PULL TEST PERFORMED/PROVIDED AS REQUIRED-ST | Closed |
| Jul 28, 2026 | ECB | Cranes and Derricks: OBSERVED INSTALLED FIXED MONORAIL MULTIPOINT SUSPENDED SCAFFOLD ON SITE-UPON CHECKING DOB RECORDS-NO NOTIFICATION FOR FIXED/NON ADJUSTABLE SCAFFOLD PROVIDED TO DOB AS REQUIRED(ONLY COUNTERWEIGHTS/ADJUSTABLE SCA | Open |
| Jul 27, 2026 | ECB | Construction: RESPONDING TO AN INCIDENT, WHERE WORKER ISTVAN BENEDEK RESULTED IN INJURY HIS RIGHT LEG WHEN TESTING MATERIAL HOIST, INSPECTION REVEALED. CONTRACTOR FAILURE TO SAFEGUARD, NO MEANS AND METHODS HOW TO HANDLE MATE | Open |
| Jul 27, 2026 | ECB | Construction: AT TIME OF INSPECTION OBSERVED: PRE-CAST (5' BY 5' APPROX.) PANEL INSTALLATION IN PROGRESS, USING CHAIN HOIST NOT SHOWING ON DRAWINGS. NO BLOW-UP DRAWINGS SECTION AND DETAILS FOR MANUAL RAIL SYSTEM. CREATING UN | Closed |
| Jul 16, 2026 | ECB | Construction: 18-STORY NEW BUILDING, I OBSERVED FACADE WORK AT EXPOSURES 1 AND 2 USING A SUSPENDED SCAFFOLD WHILE WORKERS WERE BELOW WITHOUT OVERHEAD PROTECTION OR A CONTROLLED ACCESS ZONE. THIS CREATED A HAZARDOUS CONDITION | Closed |