Brooklyn · Block 1756 · Lot 4 · 11206

123 Tompkins Avenue

4 floors · 6 apartments · 9,120 sq ft · built 1931 · class S9 · owner of record: Tompkins Plaza Llc

20open violations
$1,562ECB/OATH penalties owed
5HPD class C (immediately hazardous)
64dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 64 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-18 (Accepted). Agency page

Dec 31, 2026
in 64 days
1 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 80 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 308 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 795 days
Next cycle year 2028

Open violations

ECB / OATH (2) · $1,562 owed
IssuedViolationHearingBalance
Dec 5, 2023Boilers CLASS - 2
GREEN MOUNTAIN GMGS-262 BOILER=MISSING MANUAL RESET LWCO/FLUE PUSHED TOO FAR INTO CHIMNEY BASE/STORAGE>BOILER ROOM/ILLEGAL FANS/#'S 1+2 HWH'S SAFETY VALVES NOT PIPED DOWN/#3HWH NOT LEGALLY ABANDONED/STORAGE@GAS
#39100667J
Nov 18, 2024
DEFAULT
$1,562
Apr 22, 2014Boilers CLASS - 1
4A,15,32A,50A,50B,50C,50D,50E,51.50(2)PRESSURETROLS ON 1/4 PIPE-(50E PEERLESS JOT BOILER CAN NOT USE 50A PEERLESS JOT BOILER CAN NOT BE USEDW/GAS BURNER)GAS BURNER 50B NO WATER IN BOILER OPERATING LOW WATER NOT
#32073187P
Jul 30, 2014
IN VIOLATION
$0
DOB (4)
IssuedViolationStatus
Jul 2, 2025PLUMBING
BASED ON LIC #001343 BEING INACTIVE, STOP ALL PLUMBING WORK UNDER JOB #320430226 IMMEDIATELY.
#25-01435
DOB VIOLATION - ACTIVE
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#10200
DOB VIOLATION - ACTIVE
Jul 23, 2014FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00267
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#26850
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
Jul 23, 2014AEUHAZ FTC-AEU-HAZ
Active
HPD (13) · C 5 · B 7 · A 1
IssuedClassViolationCorrect by
Aug 4, 2026B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD ITEMS AT 2ND STORY BALCONY AT BUILDING FRONT AT FIRE ESCAPESep 8, 2026
Feb 18, 2026BApt 2R · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER UNIT AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHMar 25, 2026
Feb 18, 2026BApt 2L · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER UNIT AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 25, 2026
Feb 18, 2026BApt 2R · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCKABLE KNOB AT DOOR PREVENTING ENTRANCE TO FIRE ESCAPE IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHMar 25, 2026
Feb 13, 2026CApt 2L · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHFeb 13, 2026
Feb 13, 2026CApt 2L · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHFeb 13, 2026
Jan 20, 2026BApt 2R · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18235801 ISSUED 18-SEP-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(Feb 24, 2026
Sep 22, 2025AApt 2R · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 26, 2025
Aug 18, 2023B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POT FRONT OF BUILDING FIRE BALCONY AT FIRE ESCAPE, 2nd STORYSep 22, 2023
Jul 6, 2018B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POT AT 2ND STORY BALCONY, BUILDING FRONTAug 10, 2018
Sep 12, 2016CApt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM NORTH AT EAST WALL, NORTH WALL, SOUTH WALL IN THE 4th ROOM FROM EAOct 10, 2016
Sep 8, 2016CApt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1sOct 6, 2016
Sep 8, 2016CApt 2R · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM WEST AT NORTH WALL, 1st DOOR FRAME FROM WEST AT NORTH WALL, NORTH WALL, Oct 6, 2016

Issued in the last 120 days

DateSourceWhatNow
Aug 4, 2026HPD B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD ITEMS AT 2ND STORY BALCONY AT BUILDING FRONT AT FIRE ESCAPEOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 11:13 AM ET. BBL 3017560004.

Look up another building