Bronx · Block 3749 · Lot 1 · 10472

1220 Westchester Avenue

20 floors · 159 apartments · 198,104 sq ft · built 1964 · class D3 · owner of record: 1210 Croes Llc

163open violations
$82,760ECB/OATH penalties owed
49HPD class C (immediately hazardous)
44dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 44 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $1,181,100 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 96 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 198,104 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 165 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 165 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 288 days
Registered through 2027-09-01
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3749). Agency page

Dec 31, 2029
in 1140 days
Next due 2029
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-28 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (33) · $82,760 owed
IssuedViolationHearingBalance
Nov 10, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION OF A 20-STORY BUILDING, I OBSERVED TEMPORARY EQUIPMENT ERECTED NOT MAINTAIN AS REQUIRE BY CODE 3307.6.4.10 MUDSILLS ROTTER AND DAMAGED AND NOT PROPERLY SECURE WITH NAILS, CREATING A UN
#39561759Z
Jan 15, 2027
PENDING
$2,400
Nov 10, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION OF A 20-STORY BUILDING, I OBSERVED SIDEWALK SHED ERECTED AROUND THE ENTIRE BUILDING, UPON REVIEWING/RESEARCH DOB NOW AND BIS SYSTEM REVEALS NO PERMIT ON RECORD FOR LIGHTS INSTALLED UND
#39561756N
Jan 15, 2027
PENDING
$1,250
Nov 10, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION FOR A 20-STORY BUILDING, I OBSERVED A SIDEWALK SHED ERECTED AROUND THE RESIDENTIALS BUILDING NOT MAINTAIN AS PER CODE 3307.6.5.6 SHARP EDGES NOT PROPERLY COVERED WITH DUCK TAPE OR SCR
#39561764N
Jan 15, 2027
PENDING
$2,400
Nov 10, 2026Construction CLASS - 2
I OBSERVED THE SWS WAS NOT MAINTAINED IN A SAFE CONDITION, CONTRARY TO BC 3307.6.5.1 & 3307.6.5.10 OVERHEAD PARAPET PANELS AT EXP#1 WERE LOOSE AND IMPROPERLY SECURED, APPROX. 20 FT OF PARAPET PANELS AT EXP #4 W
#39561766R
Jan 15, 2027
PENDING
$2,400
Oct 12, 2026Unknown CLASS - 2
DURING MY INSPECTION OF AN EXISTING 20-STORY ALT. I OBSERVED NO ACTIVE WORK. MY REVIEW OF THE PERMITS ON FILE SHOWED THAT THE TEMPORARY CONSTRUCTION EQUIPMENT; IN PLACE. THE SIDEWALK SHED PERMIT EXPIRED ON 10/0
#39560447P
Dec 18, 2026
PENDING
$1,250
Oct 1, 2026Construction CLASS - 2
AT TIME OF INSPECTION OF THE 20-STORY BUILDING, I OBSERVED THE SIDEWALK SHED WAS NOT MAINTAINED IN A SAFE CONDITION. PARAPET PROTECTION WAS MISSING AT EXP#3, NETTING WAS DISPLACED AND UNSECURED, MULTIPLE MUDSIL
#39560045M
Dec 18, 2026
PENDING
$6,000
Sep 9, 2026Construction CLASS - 2
OBSERVED 20 STORY OCCUPIED RESIDENTIAL BUILDING WITH SIDE WALK SHED ERECTED AROUND PERIMETER. AT TIME OF INSPECTION I OBSERVED DAMAGED PARAPET WALLS INADEQUATE NETTING AND MISSING DAMAGED AND UNSECURED MUDSILLS
#39558972K
Nov 20, 2026
PENDING
$2,400
Sep 8, 2026Construction CLASS - 2
WORK WITHOUT A PERMIT. I OBSERVED A FULL HEIGHT PARTITION WALL WITH A DOOR ERECTED INSIDE THE DINING ROOM OF APARTMENT #19A FOR THE CREATION OF TURNING A 1BDRM APARTMENT INTO A 2 BEDROOM APARTMENT. NO PERMIT ON
#39203235H
Nov 20, 2026
PENDING
$1,250
Aug 11, 2026Construction CLASS - 2
OBSERVED OCCUPIED 20 STORY OCCUPIED BUILDING WITH SIDEWALK SHED ERECTED AROUND PERIMETER OF BUILDING. SIDEWALK SHED WAS NOT MAINTAINED AS PER CODE. DAMAGED/LEANING PARAPET WALLS, INADEQUATE NETTING, MISSING/DAM
#39557786M
Oct 16, 2026
DEFAULT
$2,430
Jul 20, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION I OBSERVED A SIDEWALK SHED ERECTED AROUND RESIDENTIAL 21 STORY BUILDING. SIDEWALK SHED IS NOT COMPLIANT AT THE TIME OF INSPECTION. OBSERVE ROTTED MUDSILLS, LEANING PARAPET PANELS & MIS
#39556804M
Oct 2, 2026
DEFAULT
$2,430
May 27, 2026Elevators CLASS - 2
1) MISSING RESTRICTOR (CEASE USE). 2) IN-CAR COMMUNICATION INOPERATIVE. 3) MISSING 2026 ELEVATOR MAINTENANCE LOG.
#39189947H
Aug 21, 2026
ADMIT/IN-VIO
$0
Apr 29, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION, I OBSERVED SIDEWALK SHED ERECTED ALL AROUND THE BUILDING NOT MAINTAIN AS PER CODE, MISSING PROTECTION FOR SHARP EDGES, PARAPET PANEL MISSING AND LEARNING AND AT ALL EXPOSURE ROTTER MU
#39553630H
Jul 17, 2026
DEFAULT
$10,000
Apr 20, 2026Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE CYCLE 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITION DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #908353. REMEDY: FILE ACCEPTABLE REPORT.
#37036866X
Aug 21, 2026
DEFAULT
$6,250
Apr 6, 2026Construction CLASS - 2
OBSERVED MISSING PANELS AT EXPOSURE 1 AND 3, AND DETERIORATED PANELS AT EXPOSURE 2 ON THE SIDEWALK SHED. THESE CONDITIONS AFFECT PEDESTRIAN PROTECTION AND SITE SAFETY AND COULD BE HAZARDOUS IN HIGH WIND. VIOLA
#39552641Z
Jul 17, 2026
DEFAULT
$10,000
Mar 25, 2026Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED THAT THE ELECTRICAL PERMIT FOR SIDEWALK SHED LIGHTING (PERMIT #X01092621-I1-EL) EXPIRED ON 10/28/2024. ELECTRICAL EQ REMAINS IN USE WITHOUT A VALID PERMIT, IN VIOLATION OF BC 28-
#39552160H
May 29, 2026
DEFAULT
$6,250
Mar 9, 2026Construction CLASS - 2
OBSERVED LOOSE DEBRIS NETTING AT EXP 1,2,& 3 ON A SIDEWALK SHED AT A 20 STORY RESIDENTIAL BUILDING. LOOSE NETTING CANNOT PROTECT AGAINST FALLING DEBRIS OR MATERIAL ALONG WITH NETTING ON THE GROUND THAT CAN CAUS
#39551380P
May 15, 2026
DEFAULT
$10,000
Sep 16, 2025Unknown CLASS - 2
AT TIME OF MY INSPECTION OF A RECURRING CONDITION AT A OCCUPIED BUILDING WITH SIDEWALK SHED.SIDEWALK SHED PERMIT IS EXPIRED SINCE 7/14/2024 AND IN VIOLATION SINCE 07/15/2025 COMPLAINT #:2420290. CONDITION REMAI
#39544932Z
Nov 21, 2025
IN VIOLATION
$625
Jul 15, 2025Unknown CLASS - 2
AT TIME OF INSPECTION OF A 20-STORY RESIDENTIAL BUILDING, I OBSERVED SIDEWALK SHED ERECTED AROUND BUILDING. UPON REVIEWING THE DEPARTMENT OF BUILDING RECORDS SYSTEM IS SHOWING PERMIT EXPIRED SINCE 7/14/2024 AND
#39542394L
Jan 9, 2026
IN VIOLATION
$1,250
May 15, 2025Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. NOTE: ECB #35674543P ISSUED ON 12-14-2023(FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES) AND DOB #121423LL0902 IF ISSUED ON 12-14-2023(TO SUBMIT
#35693793L
Nov 21, 2025
IN VIOLATION
$2,500
May 15, 2025Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: OBSERVED AT(1) ROOF LEVEL LOOSE PANEL SECTION OF ROOF AT THE SOUTH ELEV.(EXPO #1). (2)BROKEN GLASS PANELS/CRACKED OF BALCONIES PARAPET AT (2
#35693792J
Nov 21, 2025
IN VIOLATION
$2,500
May 13, 2025Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT OR INSTALLATION ON SITE - EXPIRED PERMIT. AT TIME OF INSPECTION OBSERVED SWS ERECTED UNDER PERMIT #X00985363-I1-SH ISSUED ON 04/05/2024 AND EXPIRED 07/14/2024 NO RENEWAL ON FILE
#39147906X
Oct 24, 2025
IN VIOLATION
$1,250
May 5, 2025Unknown CLASS - 2
AT TIME OF INSPECTION OF A 20-STORY OCCUPIED BUILDING, I OBSERVED SIDEWALK SHED ERECTED EXPOSURE#1-4.UPON REVIEW DOB NOW AND BIS SYSTEM SHOW PERMIT EXPIRED SINCE 07/14/2024 AND HAS NOT RENEW AS PER CODE REQUIRE
#39539833R
Oct 24, 2025
IN VIOLATION
$1,250
Feb 27, 2025Unknown CLASS - 2
AT TIME OF INSPECTION OF A 20-STORY OCCUPIED BUILDING OBSERVED SIDEWALK SHED ERECTED AT EXP#1-4. UPON REVIEWING DEPARTMENT OF BUILDING RECORDS SHOW SIDEWALK SHED PERMIT EXPIRED SINCE 07/14/2024,AND HAS NOT RENE
#39537350N
May 16, 2025
IN VIOLATION
$1,250
Dec 9, 2024Elevators CLASS - 1
RESPONDING TO A 311 ELEVATOR COMPLAINT; UPON INSPECTION, CEASE USE VIOLATION WAS ISSUED FOR THE FOLLOWING ITEMS. 1, ALARM BELL SYSTEM NOT WORKING, 2, IN CAR PHONE NOT WORKING. 3, DAMAGE PIT STOP SWITCH FOR CAR.
#39132436Z
Feb 21, 2025
IN VIOLATION
$0
Apr 18, 2024Construction CLASS - 2
AT TIME OF INSPECTION OF 20 STORY RESIDENTIAL BUILDING OBSERVED SIDEWALK SHED IN PLACE NOT MAINTAINED AS PER 3307.6.5.3- 1. PARAPETS MISSING NOT SECURED 2. VERTICAL MEMBERS MORE THAN 18 " FROM CURBLINE CAUSING
#39527736R
Jul 5, 2024
IN VIOLATION
$2,400
Apr 11, 2024Construction CLASS - 2
AT 520AM OBSERVED SEVERAL DEFECTIVE LIGHTS CREATING DARK AREAS EXP1AND4,BC3307.6.4.8 STATES SIDEWALK SHEDS SHALL ILLUMINATE AT ALL TIMES AND UNIFORMLY DISTRIBUTED ALONG THE ENTIRE LENGTH OF THE SHED,BUILDING OW
#39527426L
Nov 14, 2025
IN VIOLATION
$2,400
Jan 30, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES.AT TIME OF INSPECTION OBSERVED GUARDRAIL BASE SLEEVES AND CONNECT POST IS LOOSEN AT ROOF TOP OF EXPOSURE 1 WEST ELEVATION AND OF EXPOS 3 EAST ELEV.SPALLED BR
#35679983L
Apr 5, 2024
IN VIOLATION
$0
Dec 28, 2023Construction CLASS - 2
OBSERVED FAILURE TO MAINTAIN FACADES AT EXP.1,2,3&4 THAT ARE IN SEVERE STATE OF DISREPAIR WITH MULT. STEP-CRACKS, SPALLING & BROKEN BRICKS W. SIGNS OF WATER INFILTRATION AT VARIOUS LOCATIONS THAT CAN LEAD TO ST
#39102405Z
Apr 12, 2024
IN VIOLATION
$0
Dec 28, 2023Construction CLASS - 2
OBSERVED FAILURE TO MAINTAIN AT MULT. FLRS. OF THE B,C,D,E,G&H APT. LINE. INTERIOR (NON-LOAD & LOAD BEARING) WALLS IN DISREPAIR WITH MULT. STEP-CRACKS IN BEDROOMS & LIVING ROOMS, MOLD BUILDUP DUE TO IMPROPER VE
#39102406K
Apr 12, 2024
IN VIOLATION
$0
Dec 21, 2023Construction CLASS - 2
OBSERVED IN BASEMENT IN THE LAUNDRY ROOM INSTALLED NEW WASTE LINES FOR WASHING MACHINE ALL WORK COMPLETED NO PERMITS, OBTAIN ALL PERMITS
#39102081L
Apr 5, 2024
ADMIT/IN-VIO
$0
Dec 13, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: AT TIME OF INSPECTION OF A 20 STORY BUILDING FACADE OBSERVED AT EXPO. # 1 AND EXPO. #3 CRACKS FROM 2ND FLOOR TO 11TH FLOOR (AT CORNERS ) AND SEVERAL PLACE
#39101310L
Mar 15, 2024
IN VIOLATION
$625
Dec 9, 2022Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#908353.REMEDY:SUBMIT ACCEPTABLE REQUIRE
#37024437J
Mar 3, 2023
IN VIOLATION
$0
Jan 23, 2019Boilers CLASS - 2
B254,16,32A,50A,50B,50C. FEDERAL BOILER MDL FST 350: 50A-VACUUM TANK LEAKING STEAM AND WATER; 50B-CONDENSATION TANK LEAKING; 50C-FRESH AIR FAN SAIL SWITCH IS JUMPED OUT; RMDY: REPAIR VIOLATING CONDITIONS AND
#32097843K
Mar 15, 2019
STIPULATION/IN-VIO
$0
DOB (6)
IssuedViolationStatus
Jun 2, 2025CONSTRUCTION
PARTIAL VACATE ORDER ON A BUILDING 1210 CROES AVE HAD UNSAFE FILING SINCE 12/14/23 AND NO REPAIR HAS BEEN DONE UNTIL TODAY. AS FOLLOW UP FOR THE UNSAFE CONDITION HAS THEREFORE MADE THE ENTIRE ROOF UNABLE TO BE OCCUPIED. REMEDY: VACATE ENTIRE ROOF
#LL0901AK
DOB VIOLATION - ACTIVE
Sep 18, 2024HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#911926
DOB VIOLATION - ACTIVE
Dec 14, 2023CONSTRUCTION
DUE TO THE IMMEDIATE HAZ.TO PUBLIC SAFETY AT WEST ELEVATION EXPO#1 21 FLOOR BALCONY WITH CRACKED/SPALLING BALCONY CURB WITH THE POTENTIAL HAZ.TO THE BALCONIES BELOVED ON THE C LINE.REMEDY:VACATE ALL BALCONIES ON THE BALCONY LINE C WEST ELEVATION EXPOSURE 1 CROES AVENUE
#LL2093JF
DOB VIOLATION - ACTIVE
May 31, 2022FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#21X0001
DOB VIOLATION - ACTIVE
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#00935
DOB VIOLATION - ACTIVE
Jul 1, 1987LL10/80-LOCAL LAW 10/80 - FACADE

#NRF01494
DOB VIOLATION - ACTIVE
DOB NOW Safety (9)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Sep 18, 2024Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
HPD (121) · C 49 · B 62 · A 9
IssuedClassViolationCorrect by
May 6, 2026I771 (I) §27-2096 HMC: PROPERTY REGISTRATION WAS FILED WITH FALSE OR INCOMPLETE INFORMATION RELATED TO THE PROPERTY CONTACTS. FILE WITH THIS DEPARTMENT A TRUE REGISTRATION STATEMENT FOR THE BUILDING.—
Nov 10, 2026BApt 5E · §27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT INCORRECT LOCATION LOCATED AT APT 5E, 5th STORY, 3rd APARTMENT FROM SOUTH AT WESTDec 15, 2026
Nov 10, 2026BApt 5F · §27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT INCORRECT LOCATION LOCATED AT APT 5F, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTDec 15, 2026
Nov 10, 2026BApt 5A · §27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT INCORRECT LOCATION LOCATED AT APT 5A, 5th STORY, 3rd APARTMENT FROM NORTH AT EASTDec 15, 2026
Oct 29, 2026BApt 10H · §27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT .. LOCATED AT APT 10H, 10th STORY, 2nd APARTMENT FROM NORTH AT EASTDec 3, 2026
Oct 26, 2026CApt 3F · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 30 SQ FT AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 4th APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18709838 ISSUED 09-MAR-26 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVNov 21, 2026
Oct 19, 2026CApt 20G · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQ FEET AT CEILING AND WEST WALL IN THE 1st BATHROOM FROM EAST LOCATED AT APT 20G, 20th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18815885 ISSUED 23-APR-26 HAS BEEN UPGRADED TO CLASSNov 14, 2026
Oct 19, 2026CApt 20G · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQ FEET AT CEILING, NORTH, SOUTH, AND WEST WALLS IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 20G, 20th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18815880 ISSUED 23-APR-26 HAS BEEN UNov 14, 2026
Oct 15, 2026BApt 16F · §27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT LOCATION ( MOUNTED AT PRIVATE HALLWAY ) LOCATED AT APT 16F, 15th STORY, 4th APARTMENT FROM SOUTH AT WESTNov 19, 2026
Oct 14, 2026BApt 19B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 19B, 19th STORY, 4th APARTMENT FROM NORTH AT EASTNov 18, 2026
Oct 14, 2026AApt 19B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING OBSERVED LESS 10 SQ FEET IN THE BATHROOM LOCATED AT APT 19B, 19th STORY, 4th APARTMENT FROM NORTH AT EASTJan 17, 2027
Oct 14, 2026BApt 19B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE FLOOR IN THE TERRACE LOCATED AT APT 19B, 19th STORY, 4th APARTMENT FROM NORTH AT EASTNov 18, 2026
Sep 8, 2026BApt 3D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FEET AT EAST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18878384 ISSUED 08-MAY-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVEOct 13, 2026
Aug 14, 2026CApt 7A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING 10 SQ. FTG. & WEST WALL APPROXIMATELY 5 SQ FT IN THE BATHROOM LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 16531259 ISSUED 15-DEC-23 HAS BEEN UPGRADED TO CLASS C PER ASep 9, 2026
Aug 12, 2026CApt 1H · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 30 SQ FEET AT CEILING, EAST WEST AND SOUTH WALLS IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18947721 ISSUED 18-MAY-26 HAS BEEN UPGRADED TO CLASS C PERSep 7, 2026
Aug 12, 2026CApt 20E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 15 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 20E, 19th STORY, 3rd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 16954494 ISSUED 04-MAY-24 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE 27Sep 7, 2026
Jul 10, 2026B§ 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUEST. DATA REQUESTED FOR THE PERIOD OF MAY 2026Aug 14, 2026
Jul 10, 2026B§ 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUEST. DATA REQUESTED FOR THE PERIOD OF APRIL 2026Aug 14, 2026
Jul 9, 2026BApt 4B · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 4th APARTMENT FROM NORTH AT EASTAug 13, 2026
Jul 9, 2026BApt 4B · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASHBASIN IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 4th APARTMENT FROM NORTH AT EASTAug 13, 2026
Jul 9, 2026BApt 4B · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 4th APARTMENT FROM NORTH AT EASTAug 13, 2026
Jul 9, 2026BApt 4F · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WESTAug 13, 2026
Jul 9, 2026BApt 4F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WESTAug 13, 2026
Jul 9, 2026BApt 4F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR AT LOWER BASE CABINET AT NORTH WALL IN THE KITCHEN LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WESTAug 13, 2026
Jul 9, 2026AApt 4F · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WESTOct 12, 2026
Jul 9, 2026CApt 4B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 4th APARTMENT FROM NORTH AT EASTAug 4, 2026
Jul 9, 2026CApt 4B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 4th APARTMENT FROM NORTH AT EASTAug 4, 2026
Jul 9, 2026BApt 4B · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASHBASIN IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 4th APARTMENT FROM NORTH AT EASTAug 13, 2026
Jul 7, 2026BApt 4F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WESTAug 11, 2026
Jul 7, 2026BApt 4F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WESTAug 11, 2026
Jun 16, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS AT LOWER WINDOW PANE AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORYJul 21, 2026
Jun 8, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMASep 11, 2026
Jun 8, 2026BApt 4F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WESTJul 13, 2026
Jun 8, 2026BApt 4F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WESTJul 13, 2026
Jun 8, 2026BApt 4F · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT DRAIN IN THE TERRACE LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WESTJul 13, 2026
Jun 8, 2026BApt 4F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL AND BEHIND STOVE IN THE KITCHEN LOCATED AT APT 4F, 4th STORY, 4th APARTMENT FROM SOUTH AT WESTJul 13, 2026
Jun 4, 2026BApt 21G · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 10 SQ FEET AT CEILING IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 21G, 21st STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18591702 ISSUED 14-JAN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRJul 9, 2026
Jun 3, 2026CApt 3F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORYJun 29, 2026
Jun 3, 2026CApt 3D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORYJun 29, 2026
Jun 3, 2026BApt 3F · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORYJul 8, 2026
Jun 3, 2026BApt 3F · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORYJul 8, 2026
Jun 3, 2026BApt 3F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 3F, 3rd STORYJul 8, 2026
May 29, 2026CApt 1H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM NORTH AT EASTJun 24, 2026
May 29, 2026BApt 1H · §27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM NORTH AT EASTJul 3, 2026
May 29, 2026BApt 1H · § 27-2005 HMC: REFIT WOOD CLOSET DOOR AT WEST IN THE PRIVATE HALLWAY LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM NORTH AT EASTJul 3, 2026
May 29, 2026CApt 1H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM NORTH AT EASTJun 24, 2026
May 14, 2026BApt 6G · §27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM NORTH AT EASTJun 18, 2026
May 12, 2026BApt 6E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT NORTH WALL IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTJun 16, 2026
May 12, 2026BApt 6E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ROTTEN WOOD BASE CABINET AT SOUTH IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTJun 16, 2026
May 12, 2026CApt 6E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTJun 7, 2026
May 12, 2026CApt 6E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTJun 7, 2026
May 12, 2026BApt 6E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GROUT AND MORTAR JOINTS AT BATHTUB PERIMETER IN THE BATHROOM LOCATED AT APT 6E, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTJun 16, 2026
Apr 30, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 3, 2026
Apr 29, 2026CApt 20E · § 27-2005, 2007 HMC: REMOVE THE ILLEGAL DOUBLE CYLINDER KEY OPERATED LOCKING DEVICE AT DOOR DOUBLE CYLINDER KEY OPERATED LOCK IN THE ENTRANCE LOCATED AT APT 20E, 20th STORY, 3rd APARTMENT FROM SOUTH AT WESTMay 5, 2026
Apr 29, 2026CApt 20E · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 7; IN THE ENTIRE APARTMENT LOCATED AT APT 20E, 20th STORY, 3rd AMay 25, 2026
Apr 29, 2026BApt 20E · §27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT WRONG LOCATION IN THE ENTIRE APARTMENT LOCATED AT APT 20E, 20th STORY, 3rd APARTMENT FROM SOUTH AT WESTJun 3, 2026
Apr 29, 2026CApt 20E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 20E, 20th STORY, 3rd APARTMENT FROM SOUTH AT WESTMay 25, 2026
Apr 29, 2026BApt 20E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT NORTH IN THE BATHROOM LOCATED AT APT 20E, 20th STORY, 3rd APARTMENT FROM SOUTH AT WESTJun 3, 2026
Apr 15, 2026BApt 21F · §27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 21F, 21st STORY, 4th APARTMENT FROM SOUTH AT WESTMay 20, 2026
Mar 16, 2026BApt 3F · §27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, 4th APARTMENT FROM SOUTH AT WESTApr 20, 2026

Showing 60 of 121. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Nov 10, 2026ECBConstruction: AT THE TIME OF INSPECTION OF A 20-STORY BUILDING, I OBSERVED TEMPORARY EQUIPMENT ERECTED NOT MAINTAIN AS REQUIRE BY CODE 3307.6.4.10 MUDSILLS ROTTER AND DAMAGED AND NOT PROPERLY SECURE WITH NAILS, CREATING A UNOpen
Nov 10, 2026ECBUnknown: AT THE TIME OF INSPECTION OF A 20-STORY BUILDING, I OBSERVED SIDEWALK SHED ERECTED AROUND THE ENTIRE BUILDING, UPON REVIEWING/RESEARCH DOB NOW AND BIS SYSTEM REVEALS NO PERMIT ON RECORD FOR LIGHTS INSTALLED UNDOpen
Nov 10, 2026ECBConstruction: AT THE TIME OF INSPECTION FOR A 20-STORY BUILDING, I OBSERVED A SIDEWALK SHED ERECTED AROUND THE RESIDENTIALS BUILDING NOT MAINTAIN AS PER CODE 3307.6.5.6 SHARP EDGES NOT PROPERLY COVERED WITH DUCK TAPE OR SCROpen
Nov 10, 2026ECBConstruction: I OBSERVED THE SWS WAS NOT MAINTAINED IN A SAFE CONDITION, CONTRARY TO BC 3307.6.5.1 & 3307.6.5.10 OVERHEAD PARAPET PANELS AT EXP#1 WERE LOOSE AND IMPROPERLY SECURED, APPROX. 20 FT OF PARAPET PANELS AT EXP #4 WOpen
Nov 10, 2026HPD B§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT INCORRECT LOCATION LOCATED AT APT 5E, 5th STORY, 3rd APARTMENT FROM SOUTH AT WESTOpen
Nov 10, 2026HPD B§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT INCORRECT LOCATION LOCATED AT APT 5F, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTOpen
Nov 10, 2026HPD B§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT INCORRECT LOCATION LOCATED AT APT 5A, 5th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 29, 2026HPD B§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT .. LOCATED AT APT 10H, 10th STORY, 2nd APARTMENT FROM NORTH AT EASTOpen
Oct 26, 2026HPD C§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 30 SQ FT AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 4th APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18709838 ISSUED 09-MAR-26 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVOpen
Oct 19, 2026HPD C§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQ FEET AT CEILING AND WEST WALL IN THE 1st BATHROOM FROM EAST LOCATED AT APT 20G, 20th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18815885 ISSUED 23-APR-26 HAS BEEN UPGRADED TO CLASSOpen
Oct 19, 2026HPD C§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQ FEET AT CEILING, NORTH, SOUTH, AND WEST WALLS IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 20G, 20th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18815880 ISSUED 23-APR-26 HAS BEEN UOpen
Oct 15, 2026HPD B§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT LOCATION ( MOUNTED AT PRIVATE HALLWAY ) LOCATED AT APT 16F, 15th STORY, 4th APARTMENT FROM SOUTH AT WESTOpen
Oct 14, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 19B, 19th STORY, 4th APARTMENT FROM NORTH AT EASTOpen
Oct 14, 2026HPD A§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING OBSERVED LESS 10 SQ FEET IN THE BATHROOM LOCATED AT APT 19B, 19th STORY, 4th APARTMENT FROM NORTH AT EASTOpen
Oct 14, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE FLOOR IN THE TERRACE LOCATED AT APT 19B, 19th STORY, 4th APARTMENT FROM NORTH AT EASTOpen
Oct 12, 2026ECBUnknown: DURING MY INSPECTION OF AN EXISTING 20-STORY ALT. I OBSERVED NO ACTIVE WORK. MY REVIEW OF THE PERMITS ON FILE SHOWED THAT THE TEMPORARY CONSTRUCTION EQUIPMENT; IN PLACE. THE SIDEWALK SHED PERMIT EXPIRED ON 10/0Open
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Oct 1, 2026ECBConstruction: AT TIME OF INSPECTION OF THE 20-STORY BUILDING, I OBSERVED THE SIDEWALK SHED WAS NOT MAINTAINED IN A SAFE CONDITION. PARAPET PROTECTION WAS MISSING AT EXP#3, NETTING WAS DISPLACED AND UNSECURED, MULTIPLE MUDSILOpen
Sep 9, 2026ECBConstruction: OBSERVED 20 STORY OCCUPIED RESIDENTIAL BUILDING WITH SIDE WALK SHED ERECTED AROUND PERIMETER. AT TIME OF INSPECTION I OBSERVED DAMAGED PARAPET WALLS INADEQUATE NETTING AND MISSING DAMAGED AND UNSECURED MUDSILLSOpen
Sep 8, 2026ECBConstruction: WORK WITHOUT A PERMIT. I OBSERVED A FULL HEIGHT PARTITION WALL WITH A DOOR ERECTED INSIDE THE DINING ROOM OF APARTMENT #19A FOR THE CREATION OF TURNING A 1BDRM APARTMENT INTO A 2 BEDROOM APARTMENT. NO PERMIT ONOpen
Sep 8, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FEET AT EAST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18878384 ISSUED 08-MAY-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVEOpen
Aug 14, 2026HPD C§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING 10 SQ. FTG. & WEST WALL APPROXIMATELY 5 SQ FT IN THE BATHROOM LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 16531259 ISSUED 15-DEC-23 HAS BEEN UPGRADED TO CLASS C PER AOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 11:40 AM ET. BBL 2037490001.

Look up another building