Manhattan · Block 78 · Lot 44 · 10038

122 Fulton Street

6 floors · 10,238 sq ft · built 1910 · class O5 · owner of record: 122 Fulton Street Llc

3open violations
$2,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
778dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 778 days
Next cycle year 2028

Open violations

ECB / OATH (1) · $2,500 owed
IssuedViolationHearingBalance
Oct 13, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. 6 STORY+CELLAR WITH STUCCO EXTERIOR ON AN INTERIOR LOT. OBSERVED AT TIME OF INSPECTION, HAZARDOUS HORIZONTAL CRACKS ALONG 6TH FL WINDOW HEADERS AND UNDER
#35733199M
Dec 17, 2026
PENDING
$2,500
DOB (2)
IssuedViolationStatus
Oct 13, 2026CONSTRUCTION
FTM BLDG IN A CODE COMPLIANT MANNER-OBSVD HAZ CRACKS ON 6FL ABOVE WINDOW HEADERS AND UNDER PARAPET WALL ALSO CRACK ON PARAPET WALL TOP OF EXP1-2 CORNER. AN ANNUAL PARAPET OBSERVATION REPORT IS REQ'D TO BE COMPLETED ANNUALLU STARTING IN 2024. SUBMIT ANNUAL OBSERVATION PARAPET REPORT FOR 2025 TO BE RE
#PI10104RJ
DOB VIOLATION - ACTIVE
Oct 13, 2026CONSTRUCTION
CORRECTIVE ACTION PLAN REQ'D-OBSVD HORIZONTAL CRACKS ON 4FL ABOVE WINDOW HEADERS AND UNDER PARAPET WALL, CRACKED MASONRY AROUND 4FL WINDOW ON EXP1-4 CORNER. OWNER TO IMMED RETAIN REG DESIGN PROF IN GOOD STANDING WITH DOB & NYS TO EVAL ENTIRE BLDG AND SUBMIT A CORRECTIVE ACTION PLAN BY 11/03/2026
#PI10103RJ
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 13, 2026DOBCONSTRUCTION: FTM BLDG IN A CODE COMPLIANT MANNER-OBSVD HAZ CRACKS ON 6FL ABOVE WINDOW HEADERS AND UNDER PARAPET WALL ALSO CRACK ON PARAPET WALL TOP OF EXP1-2 CORNER. AN ANNUAL PARAPET OBSERVATION REPORT IS REQ'D TO BE COMPLETED ANNUALLU STARTING IN 2024. SUBMIT ANNUAL OBSERVATION PARAPET REPORT FOR 2025 TO BE REOpen
Oct 13, 2026DOBCONSTRUCTION: CORRECTIVE ACTION PLAN REQ'D-OBSVD HORIZONTAL CRACKS ON 4FL ABOVE WINDOW HEADERS AND UNDER PARAPET WALL, CRACKED MASONRY AROUND 4FL WINDOW ON EXP1-4 CORNER. OWNER TO IMMED RETAIN REG DESIGN PROF IN GOOD STANDING WITH DOB & NYS TO EVAL ENTIRE BLDG AND SUBMIT A CORRECTIVE ACTION PLAN BY 11/03/2026Open
Oct 13, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. 6 STORY+CELLAR WITH STUCCO EXTERIOR ON AN INTERIOR LOT. OBSERVED AT TIME OF INSPECTION, HAZARDOUS HORIZONTAL CRACKS ALONG 6TH FL WINDOW HEADERS AND UNDEROpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 10:41 AM ET. BBL 1000780044.