6 floors · 10,238 sq ft · built 1910 · class O5 · owner of record: 122 Fulton Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 778 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 13, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. 6 STORY+CELLAR WITH STUCCO EXTERIOR ON AN INTERIOR LOT. OBSERVED AT TIME OF INSPECTION, HAZARDOUS HORIZONTAL CRACKS ALONG 6TH FL WINDOW HEADERS AND UNDER #35733199M | Dec 17, 2026 PENDING | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Oct 13, 2026 | CONSTRUCTION FTM BLDG IN A CODE COMPLIANT MANNER-OBSVD HAZ CRACKS ON 6FL ABOVE WINDOW HEADERS AND UNDER PARAPET WALL ALSO CRACK ON PARAPET WALL TOP OF EXP1-2 CORNER. AN ANNUAL PARAPET OBSERVATION REPORT IS REQ'D TO BE COMPLETED ANNUALLU STARTING IN 2024. SUBMIT ANNUAL OBSERVATION PARAPET REPORT FOR 2025 TO BE RE #PI10104RJ | DOB VIOLATION - ACTIVE |
| Oct 13, 2026 | CONSTRUCTION CORRECTIVE ACTION PLAN REQ'D-OBSVD HORIZONTAL CRACKS ON 4FL ABOVE WINDOW HEADERS AND UNDER PARAPET WALL, CRACKED MASONRY AROUND 4FL WINDOW ON EXP1-4 CORNER. OWNER TO IMMED RETAIN REG DESIGN PROF IN GOOD STANDING WITH DOB & NYS TO EVAL ENTIRE BLDG AND SUBMIT A CORRECTIVE ACTION PLAN BY 11/03/2026 #PI10103RJ | DOB VIOLATION - ACTIVE |
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 13, 2026 | DOB | CONSTRUCTION: FTM BLDG IN A CODE COMPLIANT MANNER-OBSVD HAZ CRACKS ON 6FL ABOVE WINDOW HEADERS AND UNDER PARAPET WALL ALSO CRACK ON PARAPET WALL TOP OF EXP1-2 CORNER. AN ANNUAL PARAPET OBSERVATION REPORT IS REQ'D TO BE COMPLETED ANNUALLU STARTING IN 2024. SUBMIT ANNUAL OBSERVATION PARAPET REPORT FOR 2025 TO BE RE | Open |
| Oct 13, 2026 | DOB | CONSTRUCTION: CORRECTIVE ACTION PLAN REQ'D-OBSVD HORIZONTAL CRACKS ON 4FL ABOVE WINDOW HEADERS AND UNDER PARAPET WALL, CRACKED MASONRY AROUND 4FL WINDOW ON EXP1-4 CORNER. OWNER TO IMMED RETAIN REG DESIGN PROF IN GOOD STANDING WITH DOB & NYS TO EVAL ENTIRE BLDG AND SUBMIT A CORRECTIVE ACTION PLAN BY 11/03/2026 | Open |
| Oct 13, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. 6 STORY+CELLAR WITH STUCCO EXTERIOR ON AN INTERIOR LOT. OBSERVED AT TIME OF INSPECTION, HAZARDOUS HORIZONTAL CRACKS ALONG 6TH FL WINDOW HEADERS AND UNDER | Open |