9 floors · 30 apartments · 65,482 sq ft · built 1915 · class O8 · owner of record: Lenox Hill Hospital
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 43 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 43 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 59 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 65,482 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 287 days | Registered through 2027-09-01 |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $922,250 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2028 in 460 days | No Cycle 10 report on record yet |
| Energy audit and retro-commissioning (2030) Likely applies Local Law 87 · Calendar year 2030 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1410). Agency page | Dec 31, 2030 in 1504 days | Next due 2030 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 17, 2026 | Construction CLASS - 1 OBSERVED ON EIGHTH FLOOR APARTMENT 8B WASTE LINE STACK IS BROKEN. ON THE 9 FLOOR USING FERNCO COUPLING ON WASTE LINE. HOLE PENETRATIONS IN APARTMENTS 7B, 8B, AND 9B NO FIRE STOP IN PLACE WHICH CONTRARY TO CODE #39185011M | Jun 25, 2026 IN VIOLATION | $0 |
| Apr 11, 2024 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B AND 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#905114.AGG2 HISTORY OF NONCOMPLI #37027523J | Jul 11, 2024 IN VIOLATION | $0 |
| Oct 19, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#805114.AGG1:PRIOR NOV 37021475R UNDER 2 #37022960P | Feb 9, 2023 IN VIOLATION | $0 |
| Jun 1, 2021 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #805114.AGG1:PRIOR NOV 37013352R UNDER 2 #37021475R | Oct 20, 2022 ADMIT/IN-VIO | $0 |
| Nov 15, 2019 | Construction CLASS - 2 27-929.1FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BLDG 100'OR MORE IN HEIG #37016685Z | Mar 12, 2020 IN VIOLATION | $0 |
| Oct 15, 2018 | Local Law CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #805114. RMDY: SUBMIT REQUIRED TECHNICAL REPORT #37013352R | Mar 28, 2019 IN VIOLATION | $0 |
| May 14, 2008 | Construction Non-Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O 95023 C OF O INDICATES 2 FL SHOULD OCCUPY AS 1 CLASS A APT AND OFFICE 4/5 2 CLASS A APTS AND OFFICE ON EACH FL ILLEGAL OCCUPANCY NOTED 2/3 FL OCCUPIED AS 3 OFFIC #34650090Z | Mar 19, 2009 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 7, 2025 | FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) CYCLE 9 FAILURE TO CORRECT SWARMP CONDITIONS #00025 | DOB VIOLATION - ACTIVE |
| Feb 19, 2025 | HAZARDOUS CONDITION (FACADE) CYCLE 9B UNSAFE REPORT FILED #912038 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| May 7, 2025 | Facades FISPFCS CYCLE 9 FAILURE TO CORRECT SWARMP CONDITIONS | Active |
| Feb 19, 2025 | Facades FISPHAZ CYCLE 9B UNSAFE REPORT FILED | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 7, 2025 | B | Apt 6B · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .. IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | May 12, 2025 |
| Apr 7, 2025 | C | Apt 6B · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Apr 7, 2025 |
| Apr 7, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM | Apr 13, 2025 |
| Nov 8, 2024 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Nov 14, 2024 |
| Oct 21, 2024 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING SIGN AT PUBLIC HALL, 1st STORY | Oct 27, 2024 |
| Oct 21, 2024 | B | Apt 6B · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASH BASIN IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 25, 2024 |
| Oct 21, 2024 | B | Apt 6B · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 25, 2024 |
| Oct 21, 2024 | B | Apt 6B · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 25, 2024 |
| Oct 21, 2024 | B | Apt 6B · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT BATH TUB IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 25, 2024 |
| Oct 21, 2024 | B | Apt 6B · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATH TUB IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 25, 2024 |
| Oct 21, 2024 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR AT BOILER ROOM | Oct 27, 2024 |
| Apr 27, 2006 | A | Apt 6B · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DISCLORED HOT WATER AT THE WASH BASIN AND BATH TUB IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 5, 2006 |
| Apr 27, 2006 | B | Apt 6B · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 6, 2006 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 18, 2026, 1:35 PM ET. BBL 1014100064.