Manhattan · Block 819 · Lot 39 · 10011

122 5th Avenue

11 floors · 244,069 sq ft · built 1900 · class O6 · owner of record: 122 Fifth Assoc

4open violations
$26,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
62dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-20 (Payment Verification In Progress). Agency page

Dec 31, 2026
in 62 days
1 of 1 without an accepted 2026 report yet
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $4,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 114 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 244,069 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 183 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 183 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1158 days
Next cycle year 2029
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 819). Agency page

Dec 31, 2029
in 1158 days
Next due 2029

Open violations

ECB / OATH (5) · $26,250 owed
IssuedViolationHearingBalance
May 27, 2026Unknown CLASS - 1
NOTE: AT TIME OF INSPECTION, I OBSERVED ACTIVE CONSTRUCTION OPERATIONS ON THE 4TH AND 5TH FLOORS, UPON REQUEST FOR OCCUPANT PROTECTION PLAN WHICH INCLUDES ALL PROTECTIVE MEANS TO PROTECT THE OCCUPANTS AGAINST H
#39554690Y
Feb 22, 2027
$5,000
May 27, 2026Unknown CLASS - 2
AT TIME OF A FOLLOW-UP INSPECTION FOR AN INCIDENT THAT OCCURRED ON 05/26/2026 WHERE A WORKER FELL THROUGH A SCAFFOLD FROM THE 5TH FL TO THE 4TH FL. UPON REQUEST FOR THE WORKER SCAFFOLD CERTIFICATE TO VERIFY COM
#39554688P
Feb 22, 2027
$1,250
May 27, 2026Construction CLASS - 1
AT TIME OF A FOLLOW-UP INSPECTION FOR AN INCIDENT THAT OCCURRED ON 05/26/2026 WHERE A WORKER FELL THROUGH A SCAFFOLD FROM THE 5TH FL TO THE 4TH FL. INSPECTION REVEALED THAT THE SCAFFOLD WAS NOT PROPERLY PLANKED
#39554687N
Feb 22, 2027
$10,000
May 27, 2026Construction CLASS - 1
AT TIME OF A FOLLOW-UP INSPECTION FOR AN INCIDENT THAT OCCURRED ON 05/26/2026 WHERE A WORKER FELL THROUGH A SCAFFOLD FROM THE 5TH FL TO THE 4TH FL. INSPECTION REVEALED THAT THE PERMIT HOLDER DID NOT NOTIFY THE
#39554691X
Feb 22, 2027
$5,000
May 27, 2026Unknown CLASS - 1
NOTE: AT THE TIME OF INSPECTION, I OBSERVED AN ELEVATED SCAFFOLD APPROXIMATELY 40 FEET IN HEIGHT. UPON REQUEST FOR THE SCAFFOLD DESIGN DRAWINGS AS REQUIRED BY 3301.6, NONE WERE AVAILABLE CREATING SIGNIFICANT CO
#39554704X
Jul 15, 2027
DEFAULT
$5,000
DOB (2)
IssuedViolationStatus
Aug 26, 2026LANDMARK

#27-0075
DOB VIOLATION - ACTIVE
Aug 20, 2004ELEVATOR

#9444/107144
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 5)
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Aug 26, 2026DOBLANDMARK: Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 5:04 AM ET. BBL 1008190039.

Look up another building