5 floors · 11 apartments · 13,400 sq ft · built 1913 · class C1 · owner of record: 1219 W Realty Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 60 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-02-13 (Accepted). Agency page | Dec 31, 2026 in 60 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 304 days | Registered through 2027-09-01 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 3, 2024 | Construction CLASS - 2 OCCUPANCY IN CONTRARY TO THAT ALLOWED BY C/O AND/OR DEPARTMENT OF BUILDING RECORD. ILLEGALLY CREATED CLASS "A" APARTMENT AT CELLAR WITH FULLBATHROOM AND KITCHEN, 2ND MEANS OF EGRESS PRESENT BY WINDOW OPENING 24 #35483467K | Jun 7, 2027 DEFAULT | $6,250 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 9, 2026 | B | Apt BASEME · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Oct 14, 2026 |
| Sep 9, 2026 | B | Apt BASEME · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Oct 14, 2026 |
| Sep 9, 2026 | C | Apt BASEME · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Oct 5, 2026 |
| Sep 9, 2026 | A | Apt BASEME · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE PRIVATE HALLWAY LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Dec 13, 2026 |
| Sep 9, 2026 | B | Apt BASEME · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT THE CEILING IN THE KITCHEN LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Oct 14, 2026 |
| Sep 9, 2026 | B | Apt BASEME · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE KITCHEN LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Oct 14, 2026 |
| Jun 9, 2026 | B | Apt 1 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 14, 2026 |
| Jun 9, 2026 | A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Sep 12, 2026 |
| Jun 9, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AND IT'S ASSEMBLY AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Jul 14, 2026 |
| Jun 9, 2026 | C | Apt 1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 5, 2026 |
| Jun 9, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AND IT'S ASSEMBLY AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Jul 14, 2026 |
| Jun 9, 2026 | B | Apt 1 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 14, 2026 |
| Jun 9, 2026 | B | Apt 1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER WINDOW SASH (2ND WINDOW FROM SOUTH AT WEST EXTERIOR WALL) IN THE 7th ROOM FROM EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 14, 2026 |
| Apr 30, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 3, 2026 |
| Feb 26, 2026 | C | Apt BASEME · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT BSMT-APT BASEME, 1st STORY, 1st BSMT-APT FROM WEST AT NORTH | Mar 4, 2026 |
| Feb 26, 2026 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Mar 4, 2026 |
| Jan 23, 2025 | B | Apt 6 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT EAST WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17297469 ISSUED 24-SEP-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CO | Feb 27, 2025 |
| Jan 23, 2025 | B | Apt 6 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT NORTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17297470 ISSUED 24-SEP-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE C | Feb 27, 2025 |
| Sep 25, 2024 | C | Apt 6 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 21, 2024 |
| Sep 25, 2024 | B | Apt 6 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE FINISH AT BATHTUB INTERIOR IN THE BATHROOM LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 30, 2024 |
| Sep 25, 2024 | C | Apt 6 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 21, 2024 |
| Aug 26, 2024 | C | Apt 5 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED GAS LINES (2) AT NORTH WALL. IN THE KITCHEN LOCATED AT APT 5, 3rd STORY | Sep 1, 2024 |
| Jul 11, 2024 | C | Apt 5 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 6, 2024 |
| Jul 11, 2024 | C | Apt 5 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF (2) TWO UNCAPPED GAS LINES AT NORTH WALL NEAR CEILLING (COVERED WITH ALUMINUM FOIL) IN THE KITCHEN LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 17, 2024 |
| Jul 8, 2024 | C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCKABLE SLIDE BOLT INSTALLED AT ENTRANCE DOOR TO ILLEGAL CELLAR NORTH APARTMENT | Jul 14, 2024 |
| Jul 8, 2024 | B | § 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS UNDER THE FLOORS AND BEHIND THE WALLS AT CREATED KITCHEN AND BATHROOM AT ILLEGAL NORTH CELLAR APARTMENT | Aug 12, 2024 |
| Jul 8, 2024 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD PANELS INSTALLED AT ALL WALLS IN THE 5TH ROOM FROM EAST AT SOUTH IN ILLEGAL CELLAR NORTH APARTMENT | Oct 11, 2024 |
| Jul 8, 2024 | B | § 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, GAS RANGE INSTALLED AT CREATED KITCHEN IN ILLEGAL CELLAR NORTH APARTMENT | Aug 12, 2024 |
| Jul 8, 2024 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION STUDS AND WALLS ERECTED FROM FLOOR TO CEILING WITH DOORS AND FRAME AT ILLEGAL CELLAR NORTH APARTMENT | Oct 11, 2024 |
| Jun 4, 2024 | B | Apt 5 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 15 SQ FT IN THE 1st ROOM FROM EAST LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 9, 2024 |
| Feb 1, 2024 | B | Apt 10 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 10, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Mar 7, 2024 |
| Feb 1, 2024 | C | Apt 10 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 10, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Feb 27, 2024 |
| Aug 10, 2023 | B | Apt 7 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 3 SQ.FT AT NORTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 15915307 ISSUED 11-APR-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE | Sep 14, 2023 |
| Oct 28, 2021 | C | Apt 9 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 9, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 23, 2021 |
| Oct 28, 2021 | C | Apt 9 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 9, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 23, 2021 |
| Nov 4, 2020 | B | Apt 5 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 3 SQ. FT MOLD AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 13713388 ISSUED 02-JUL-20 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27- | Dec 9, 2020 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 9, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Open |
| Sep 9, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Open |
| Sep 9, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Open |
| Sep 9, 2026 | HPD A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE PRIVATE HALLWAY LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Open |
| Sep 9, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT THE CEILING IN THE KITCHEN LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Open |
| Sep 9, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE KITCHEN LOCATED AT BSMT-APT BASEME, 1st BSMT-APT FROM WEST AT NORTH | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)