5 floors · 45 apartments · 44,550 sq ft · built 1919 · class C7 · owner of record: 1215 Realty, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2025-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 67 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-12 (Payment Verification In Progress). Agency page | Dec 31, 2026 in 67 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 44,550 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 14, 2026 | Construction CLASS - 1 WWOP: ATOI, OBSERVE A MAKE SHIFT FENCE INSTALLED AT THE ROOF WITH OUT ANY PERMITS ONFILE FOR THE SCOPE OF WORK QUESTIONING THE ENTIRETY OF THE STRUCTURE IN A EVENT OF A HIGH WIND SITUATION, OBTAIN PERMIT #39188643Y | Mar 22, 2027 PENDING | $2,500 |
| May 14, 2026 | Construction CLASS - 1 ALSO OBSERVE FAILURE TO MAINTAIN ON THE ROOF FOR THE EXCESSIVE CONSTRUCTION DEBRIS PILED UPB CREATING A TRIP HAZARD ON THE ROOF, REPAIR AND/REPLACE #39188642M | Mar 22, 2027 PENDING | $2,500 |
| Apr 7, 2026 | Construction CLASS - 1 FACADE IN DISREPAIR, SECTIONS OF MORTAR MISSING ALL THROUGHOUT PARAPET LEVEL WITH WALLS OUT OF PLUMB, REPAIR AND/REPLACE #39183646R | Jan 25, 2027 PENDING | $6,250 |
| Mar 23, 2026 | Unknown CLASS - 2 ELECTRICAL WIRING OBSERVED INSTALLED IN AN UNSAFE MANNER. NOTED: AT TIME OF INSPECTION ELECTRICAL EXTENSION CORD OBSERVED INSTALLED & SUPPLYING ELECTRICITY TO FLOWER SHOP STRUCTURE AT EXPOSURE 2 PATHED FROM DEL #39181443H | Dec 11, 2026 PENDING | $800 |
| Mar 23, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION - 1. AT APT 1F: BTHRM CEILING OBSERVED WITH EXCESSIVE WATER DAMAGE CAUSING A COLLAPSE POTENTIAL; 2. AT CORNER DELI: GLASS FRON #39181442X | Dec 11, 2026 | $2,500 |
| Mar 23, 2026 | Unknown CLASS - 1 W/O A PERMIT. NOTED: AT APT 1F - OBSERVED ELECTRICAL 220V LINE INSTALLED FOR A DRYER OUTLET., OBTAIN PERMIT #39181444J | Dec 11, 2026 | $2,500 |
| Mar 23, 2026 | Construction CLASS - 2 W/O A PERMIT. NOTED: AT TIME OF INSPECTION - PLEXI-GLASS STRUCTURE OBSERVED ERECTED APPRX. 20' X 5' X 12' AT EXPOSURE 2 WITH METAL ROOF, ELECTRICAL WIRING FOR OUTLETS & LIGHTS; ATTACHED TO BUILDING., OBTAIN ALL #39181440M | Dec 11, 2026 | $1,250 |
| Mar 23, 2026 | Construction CLASS - 1 FAILURE TO OBEY A VACATE ORDER FROM THE COMMISSIONER PER 28-207.4. NOTED: AT TIME OF INSPECTION - NORTH SECTION APTS F THROUGH J & CORNER DELI WERE OBSERVED RE-OCCUPIED 80% CONTRARY TO FULL VACATE ORDER # X36/2 #39181441Y | Dec 11, 2026 PENDING | $10,000 |
| Mar 17, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED FIRE ESCAPE LEADING TO THE STREET AT EXPOSURE 2 OBSTRUCTED DUE TO WOOD TRASH DOOR BLOCKING EXIT HOLE ON TOP OF THE SIDEWALK SHED, REMOVE OBSTRUCTION #39180798M | May 29, 2026 IN VIOLATION | $2,500 |
| Mar 17, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED FAILURE TO MAINTAIN SIDEWALK SHED AT EXPOSURE 1 EXCESSIVE AMOUNT TRASH,LOOSE WOOD TRASH METALS MASONRY STONESPAVERS PILES UP ON TOP OF THE SIDEWALK SHED CLOSE TO THE PANELS LEADIN #39180799Y | May 29, 2026 IN VIOLATION | $625 |
| Mar 16, 2026 | Construction CLASS - 1 ATIO OBSERVE DEMO WORK AT THE LEFT SIDE OF THE BUILDING THAT'S CURRENTLY VACANT BEING DONE WITHOUT A PERMIT ON FILE, DEMO WORK HAS STARTED AT 4TH FLOOR AND. 5TH FLOOR UNITS A FULL STOP WORK IS ISSUED FOR THE SC #39180624M | Dec 11, 2026 PENDING | $2,500 |
| Feb 2, 2026 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDINGS DEPARTMENT RECORDS. AS PER C OF O #58224 OF BASEMENT LEVEL 1ILLEGAL CLASS A APARTMENT, FULL KITCHEN RESIDENTIAL SINK; 3 PIECE BATH #35685869Z | Mar 5, 2027 PENDING | $2,500 |
| Feb 2, 2026 | Construction CLASS - 1 WORK WITHOUT A PERMIT. AT TIME OF INSPECTION AT BASEMENT OBSERVED, ASSOCIATED PLUMBING. FOR 3-PIECE BATHROOM, SINK, STAND-UP SHOWER, TOILET,RESIDENTAL SINK IN KITCHEN. NO PERMIT ON FILE. REMEDY: OBTAIN PERMIT. #35721650J | Mar 5, 2027 PENDING | $2,500 |
| Feb 2, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT C OF O 1(FRONT) 5TH FLOOR WINDOW IN SEVERE DISREPAIR; BULGING AT LENTAL, VERTICAL CRACKS, MISSING MORTAR, RIGHTSIDE AT 2N #35685873L | Apr 17, 2026 IN VIOLATION | $2,500 |
| Feb 2, 2026 | Construction CLASS - 1 WORK WITHOUT A PERMIT. AT TIME OF INSPECTION OBSERVED FULL HEIGHT PARTITIONS DIVIDING INTO 2 BEDROOMS, LIVING ROOM AND KITCHEN FOR 1 CLASS AAPARTMENT, AT FRONT SIDE OF BASEMENT 2 APARTMENTS CONVERTED IN MOSQUE, #35685872J | Mar 5, 2027 PENDING | $2,500 |
| Feb 11, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39102247M ISSUED ON 12/27/2023, AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2). AN ACCEPTABLE CERT #37033236H | May 2, 2025 IN VIOLATION | $1,250 |
| Feb 11, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39102161L ISSUED ON 12/22/2023, AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2). AN ACCEPTABLE CERT #37033235X | May 2, 2025 IN VIOLATION | $1,250 |
| Apr 1, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, I OBSERVED ADEQUATE SAFETY MEASURE(SIDEWALK SHED) AT EXPO.(1)+(2)+(3), EASY AND SOUTH AND WEST ELEVATIONS. AND I OBSERVED DAMAGED MA #35682493X | Mar 3, 2025 IN VIOLATION | $625 |
| Jan 24, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING WALL IN A CODE COMPLIANT MANNER.NOTED AT TIME OF INSPECTION. (1)EAST ELEVATION EXPOSURE #1, CRACKED AND BULGING MASONRY BRICK AT PARAPET LEVEL AND AT WINDOW LEVEL 5TH FLOOR #35679741Z | Aug 16, 2024 IN VIOLATION | $0 |
| Dec 27, 2023 | Construction CLASS - 2 OBSERVED IN APARTMENT 3E LOCATED ON THE THIRD FLOOR IN THE KITCHEN RUNNING MULTIPLE FLEX HOSES MORE THAN SIX FEET GOING THROUGH PARTITIONS TO GAS DRYER. VENT TO GAS DRYER BACK PITCHED GOING THROUGH WINDOW WHICH #39102247M | Mar 1, 2024 STIPULATION/IN-VIO | $0 |
| Dec 27, 2023 | Construction CLASS - 2 OBSERVED ON THE GROUND FLOOR IZZIS I REPAIR STORE WHICH GOES INTO THE APARTMENT BATHROOM WHICH THE HOT WATER HEATER HAS NO TEMPERATURE RELIEF VALVE DISCHARGE PIPED IN. FACET NOT MOUNTED PROPERLY WHICH IS CONTRA #39102246K | Mar 1, 2024 STIPULATION/IN-VIO | $0 |
| Dec 15, 2023 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING FACADE WALL, MORTAR MISSING FROM IN SOME AREAS OF EXP4 (GRANDVIEW PL SIDE), CORNER OF EXP4 & EXP1 FLAT CORNER WITH WINDOWS, CRACKS IN BRICKS & SHIFTING ABOVE 1ST FLOOR WINDOWS TO 5T #39101569K | Mar 1, 2024 IN VIOLATION | $0 |
| Apr 27, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG. DEFECT IS: BATHTUB OF APT 2B HAS SUNK NEARLY1 INCH. REMEDY: IMMEDIATELY MAKE ALL NECESSARY REPAIRS,OBTAIN ANY NECESSARY PERMITS,SUBMIT ENGINEERS REPORT AT TESTING TO STABILITY.(CHECK #35172716Y | Jun 17, 2016 IN VIOLATION | $0 |
| Dec 18, 2014 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY OR BLDG DEPT RECORDS.AS PER C OF O #58224 BSMNT TO BE STORAGE & DWELLING,1ST FLR TO BE DWELLING & FOOD STORE,NOW STORE & MOSQUE LOCATED @BSMNT LEVEL,B #35080505X | Mar 27, 2015 IN VIOLATION | $0 |
| Mar 17, 1997 | HPD Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY OR BLDGDEPT. RECORDS. BASEMENT CONVERTED FROM ORDINARY USE TO ILLEGAL ROOMS FOR LIVING UNITS WITH PARTITIONS ERECTED CREATING ROOMS, BATHROOM AND #34151522R | Nov 14, 1997 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 29, 2026 | CONSTRUCTION FAILURE TO COMPLY WITH COMMISSIONR'S ORDER:DOB VIOLATION #012424CFA204 04JF REQUIRED THE IMMEDIATE 100% HANDS ON INSPECTION OF ALL FACADES BY NYS REG DESIGN PRO & SUBMIT A REPORT TO FACADE VIA EMAIL BY 2/24/2024 AS OF 06/29/2026, NO HANDS ON INSPECTION REPORT SUBMITTED TO FACADE UNIT. REMEDY:COMPLY #LL20405CM | DOB VIOLATION - ACTIVE |
| Feb 26, 2026 | CONSTRUCTION EMERGENCY WORK ORDER.THE BULKHEAD WALL@SOUTH WING STAIRCASE@FRNT WALL IS IN SEVERE STATE OF DISREPAIR.THE WALL IS BULGNG&LEANING OUTWARD &AT RISK OF COLLAPSE.IMMED BRACE/STBZLE THE BULKHD WALL UNDR DRCT& CNTINUOUS SPRVSN OF PE.PE TO SBMT MEANS&METHDS BY EOD BY 2/27/26 #FEU20401XC | DOB VIOLATION - ACTIVE |
| Feb 26, 2026 | CONSTRUCTION FAILURE TO MAINTAIN.ALL STAIRCASES WERE IN STATE OF DISREPAIR,RUSTED & DETACHING THREADS AND RIZERS.UNEVEN STEPS BROKEN AND LOOSE STONE@ THREADS.OWNR TO ENGAGE PE&CNTRCTR TO EVAL ALL 3/18/26 COMPLETE BY 4/1/26 #FEU20404XC | DOB VIOLATION - ACTIVE |
| Feb 26, 2026 | CONSTRUCTION EMERGENCY WORK.THE METAL PAN STAIRS THREADS HAVE RUSTED &DETACHD FRM THE STAIR STRINGERS@NORTH WING.THE CONDITION IS NOT RELATED TO FIRE DAMAGES.IMMED REINFORCE/RE-SUPPORT ALLL STAIR THREADS RISEPS AFFECTED UNDR DRCT&CONTINUOUS SPRVSN OF PE SBMT M&M BY EOD 2/27/26 #FEU20402XC | DOB VIOLATION - ACTIVE |
| Feb 26, 2026 | CONSTRUCTION FAILURE TO MAINTAIN.THE EXTERIOR MASONRY WALLS ARE IN STATE OF DISREPAIR.BULKHEAD WALL BULGNG&LEANING.PARAPET BULGNG,CRACKED AND LEANING.RUSTED LINTELS&CRCKD BRCK IN MANY LOCATIONS.ENGAGE NYS LICENSD PE&CNTRCTR TO EVAL ENT FACADE&REPAIR UNDR PERMIT.OBTAIN PERMIT BY 3/25/26.COMPLETE BY 5/1/26 #FEU20403XC | DOB VIOLATION - ACTIVE |
| Feb 2, 2026 | CONSTRUCTION FAILURE TO MAINTAIN.DMG BY FIRE ON 2/2/26.SEVERE DAMAGE@ROOF& 5THFL WATER DMG,CLLPSD CEILNGS @A,B,C,D,&E LINES.OWNR TO ENGAGE NYSPE& CNTRCTR TO EVAL ENT BLDG&RPAIR UNDER PERMIT.OBTAIN PRMT BY 3/1/26 COMPLETE&SGN OFF BY 6/1/26 #FEU20402XC | DOB VIOLATION - ACTIVE |
| Feb 2, 2026 | CONSTRUCTION EMERGENCY WORK.BLDG DAMAGED BY FIRE ON 2/2/26.ROOF FRAMING SEVERELY DAMAGED@5D ROOF OPEN.WATER DAMAGE & DEBRIS THROUGHOUT.IMMED DO 1.INSTL TEMP ROOF SEAL ALL ROOF OPENINGS,2.INSTALL TEMP SHORNG WHERE REQ'D,3 CLEAN ALL DEBRIS.WRK TO BE PERFRMD #FEU20401XC | DOB VIOLATION - ACTIVE |
| Jan 24, 2024 | CONSTRUCTION IMMED HAZ BY THE CRACKED MASONRY BRICK&LEANING PARAPETS &BLDG MASONRY @ EAST ELEV EXP#1.REMEDY: OWNER RETAIN NYS REG DESIGN PROF TO CONDUCT 100% HANDS ON INSPECTION OF BLDGS FACADE&PARAPETS (RDP).PROVIDE INSPECTION REPORT,REPAIR PLANS PROPOSALS TO DOB FACADES UNIT FACADES@BUILDINGS.NYC.GOV. BY 02/24 #FA20404JF | DOB VIOLATION - ACTIVE |
| Jan 5, 1990 | CONSTRUCTION #351 | DOB VIOLATION - ACTIVE |
| Jan 5, 1990 | CONSTRUCTION #3S1 | VIOLATION UNSERVED ECB-ACTIVE |
| Jan 5, 1990 | CONSTRUCTION #3S1 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| May 15, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| May 15, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 6, 2026 | I | 771 (I) §27-2096 HMC: PROPERTY REGISTRATION WAS FILED WITH FALSE OR INCOMPLETE INFORMATION RELATED TO THE PROPERTY CONTACTS. FILE WITH THIS DEPARTMENT A TRUE REGISTRATION STATEMENT FOR THE BUILDING. | — |
| Feb 10, 2026 | I | § 27-2089 ADM CODE THE PREMISES HAVE BEEN VACATED BY AN ORDER OF THIS DEPARTMENT AND CANNOT BE REOCCUPIED EXCEPT FOR CARETAKER, UNTIL (1) AN APPLICATION AND PLAN FOR THE WORK REQUIRED BY THIS ARTICLE HAVE BEEN FILED WITH AND APPROVED BY THE DEPARTMENT OF BUILDINGS, WHERE REQUIRED, (2) SUCH WORK HAS | — |
| Oct 14, 2026 | B | Apt 2E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 19016816 ISSUED 15-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3) | Nov 18, 2026 |
| Oct 13, 2026 | B | Apt 4H · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASHBASIN IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 17, 2026 |
| Oct 1, 2026 | B | Apt 2G · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT DRAIN LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Nov 5, 2026 |
| Oct 1, 2026 | B | Apt 2G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Nov 5, 2026 |
| Oct 1, 2026 | B | Apt 2G · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18954850 ISSUED 21-MAY-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3 | Nov 5, 2026 |
| Oct 1, 2026 | B | Apt 2G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WASH BASIN CABINET ( FLOOR ROTTED ) IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Nov 5, 2026 |
| Oct 1, 2026 | C | Apt 2G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH AT FIRE ESCAPE IN THE KITCHEN LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Oct 7, 2026 |
| Oct 1, 2026 | B | Apt 2G · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Nov 5, 2026 |
| Sep 3, 2026 | C | Apt 4H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 29, 2026 |
| Sep 3, 2026 | B | Apt 3G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT SWITCH DEFECTIVE AT NORTH IN THE KITCHEN LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 8, 2026 |
| Aug 13, 2026 | B | Apt 3H · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ESCHUTEON PLATE AT RISER PIPE IN THE 3rd ROOM FROM EAST LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 17, 2026 |
| Aug 13, 2026 | B | Apt 3H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 17, 2026 |
| Aug 13, 2026 | A | Apt 3H · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 16, 2026 |
| Aug 13, 2026 | B | Apt 3H · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 17, 2026 |
| Aug 13, 2026 | B | Apt 3H · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 17, 2026 |
| Aug 13, 2026 | B | Apt 3H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Sep 17, 2026 |
| Jun 29, 2026 | C | Apt 2J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 15SQFT AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 2J, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18735574 ISSUED 24-MAR-26 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE 27-2017 | Jul 25, 2026 |
| Jun 29, 2026 | B | Apt 3G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE KITCHEN LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Aug 3, 2026 |
| Jun 29, 2026 | C | Apt 3G · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Jul 5, 2026 |
| Jun 29, 2026 | B | Apt 2J · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2J, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Aug 3, 2026 |
| Jun 29, 2026 | A | Apt 2J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 2J, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Oct 2, 2026 |
| Jun 29, 2026 | C | Apt 3G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Jul 25, 2026 |
| Jun 29, 2026 | A | Apt 3G · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Oct 2, 2026 |
| Jun 29, 2026 | B | Apt 2J · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2J, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Aug 3, 2026 |
| Jun 29, 2026 | B | Apt 3G · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL BY METHOD OF RE-GLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Aug 3, 2026 |
| Jun 29, 2026 | B | Apt 3G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR ( ROTTED BOTTOM ) IN THE BATHROOM LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Aug 3, 2026 |
| Jun 16, 2026 | B | Apt 2E · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 21, 2026 |
| Jun 16, 2026 | B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT VESTIBULE CEILING , 1st STORY | Jul 21, 2026 |
| Jun 16, 2026 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTUCTION MATERIALS AT PUBLIC HALL, 2nd STORY | Jul 21, 2026 |
| Jun 16, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT VESTIBULE CEILING , 1st STORY | Jul 21, 2026 |
| Jun 16, 2026 | B | Apt 2E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE FOYER LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 21, 2026 |
| Jun 16, 2026 | B | Apt 2E · § 27-2005 ADM CODE PROVIDE ESCUTCHEON PLATES AT TOP AND BOTTOM OF RISER IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 21, 2026 |
| Jun 16, 2026 | B | Apt 2E · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE FOYER LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 21, 2026 |
| Jun 16, 2026 | C | Apt 2E · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR IN THE ENTRANCE LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 30, 2026 |
| May 27, 2026 | C | Apt 2G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 22, 2026 |
| May 27, 2026 | B | Apt 2G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 1, 2026 |
| May 27, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER PROTRUDING FROM THE WINDOW SILL MORE THAN 4 INCHES AT 1st FIRE ESCAPE FROM NORTH AT WEST, 4th STORY | Jul 1, 2026 |
| May 27, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER PROTRUDING FROM THE WINDOW SILL MORE THAN 4 INCHES AT 1st FIRE ESCAPE FROM NORTH AT WEST, 3rd STORY | Jul 1, 2026 |
| May 26, 2026 | C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Jun 21, 2026 |
| May 13, 2026 | B | Apt 4H · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TIILES IN THE 1st ROOM FROM EAST LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 17, 2026 |
| May 13, 2026 | A | Apt 4H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 16, 2026 |
| May 13, 2026 | B | Apt 4H · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASHBASIN IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 17, 2026 |
| May 4, 2026 | B | Apt 4F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jun 8, 2026 |
| May 4, 2026 | B | Apt 4F · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM EAST AT S | Jun 8, 2026 |
| May 4, 2026 | B | Apt 4F · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM EAST AT SOU | Jun 8, 2026 |
| May 4, 2026 | A | Apt 4F · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING TOP EXCSEXCUTCHEON PLATE AT STEAM RISER IN THE KITCHEN LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 7, 2026 |
| May 4, 2026 | A | Apt 4F · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE STEAM RISER IN THE KITCHEN LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 7, 2026 |
| May 4, 2026 | B | Apt 4F · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jun 8, 2026 |
| May 4, 2026 | B | Apt 4F · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTICAL OUTLET COVER AT NORTH WALL IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jun 8, 2026 |
| May 4, 2026 | B | Apt 4F · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN THE WASTE LINE AT BATHTUB IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jun 8, 2026 |
| May 4, 2026 | C | Apt 4F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | May 30, 2026 |
| May 4, 2026 | B | Apt 4F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH WINDOW AT WEST WALL IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jun 8, 2026 |
| May 4, 2026 | A | Apt 4F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET AT WASH BASIN IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 7, 2026 |
| Apr 13, 2026 | B | Apt 4H · § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WASH BASIN IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH | May 18, 2026 |
| Apr 8, 2026 | B | Apt 3G · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD BASE AT EAST BASE CABINET IN THE KITCHEN LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH | May 13, 2026 |
| Apr 8, 2026 | C | Apt 4H · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH | Apr 8, 2026 |
| Apr 8, 2026 | B | Apt 3G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT SWITCH AT WEST WALL IN THE KITCHEN LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH | May 13, 2026 |
| Apr 8, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT BUILDING ENTRANCE DOOR | May 13, 2026 |
Showing 60 of 157. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 14, 2026 | HPD B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 19016816 ISSUED 15-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3) | Open |
| Oct 13, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASHBASIN IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Oct 1, 2026 | HPD B | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT DRAIN LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Open |
| Oct 1, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Open |
| Oct 1, 2026 | HPD B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18954850 ISSUED 21-MAY-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3 | Open |
| Oct 1, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WASH BASIN CABINET ( FLOOR ROTTED ) IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Open |
| Oct 1, 2026 | HPD C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH AT FIRE ESCAPE IN THE KITCHEN LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Open |
| Oct 1, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Open |
| Sep 3, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 3, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT SWITCH DEFECTIVE AT NORTH IN THE KITCHEN LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 13, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ESCHUTEON PLATE AT RISER PIPE IN THE 3rd ROOM FROM EAST LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 13, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 13, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 13, 2026 | HPD B | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 13, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Aug 13, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Jun 29, 2026 | DOB | CONSTRUCTION: FAILURE TO COMPLY WITH COMMISSIONR'S ORDER:DOB VIOLATION #012424CFA204 04JF REQUIRED THE IMMEDIATE 100% HANDS ON INSPECTION OF ALL FACADES BY NYS REG DESIGN PRO & SUBMIT A REPORT TO FACADE VIA EMAIL BY 2/24/2024 AS OF 06/29/2026, NO HANDS ON INSPECTION REPORT SUBMITTED TO FACADE UNIT. REMEDY:COMPLY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 10:11 AM ET. BBL 2024640001.