Brooklyn · Block 1510 · Lot 1 · 11233

121 Saratoga Avenue

4 floors · 37,560 sq ft · built 1900 · class W1 · owner of record: Nyc Department Of Education

9open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 16 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 37,560 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-17 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (8)
IssuedViolationHearingBalance
May 26, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3; 27-345. AT THE TIME OF INSPECTION OBSERVED AND NOTED AT CELLAR LEVEL ELECTRICAL ROOM NO FIRE STOPPING IN WALL FEW HOLE IN WL
#35732029P
Jun 26, 2026
POP/IN-VIO
$0
May 26, 2026Construction CLASS - 2
REISSUE: 35691929M DATE OF ISSUE: 04/25/2025. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGESAND PUBLIC CORRIDORS PER BC 1006.1; 27-381. AT THE TIME OF INSPECTION
#35732026J
Jun 26, 2026
POP/IN-VIO
$0
May 26, 2026Construction CLASS - 2
REISSUE #35691928K DATE OF ISSUE: 04/25/25. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED ON THE 4TH FLOOR. STAIR C AND 4TH FL. ROOM 408 DEFECTIVE HARDWARE
#35732027L
Jun 26, 2026
POP/IN-VIO
$0
May 26, 2026Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING PROPERLY. AT THE TIME OF INSPECTION OBSERVED AND NOTED AT 1ST FLOOR. OUTSIDE MAIN EXIT DOOR AT EXIT-3, 2 EXIT DOORS NOT SELF-CLOSING PROPERLY AND AT 1ST. FLOOR EXIT-2 OUTSIDE MAIN EXI
#35732028N
Jun 26, 2026
POP/IN-VIO
$0
Apr 25, 2025Construction CLASS - 2
REISSUE#35672899R FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED OBSERVED ON THE FOURTH FLOOR STAIR C THE DOORS WERE NOT CLOSING PROPERLY.REM:REPAIR AND/OR REPLACE.
#35691928K
Jul 2, 2025
POP/IN-VIO
$0
Apr 25, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:ON THE FOURTH FLOOR AUDITORIUM/GYMNASIUM FOR LIGHTS,FOURTH FLOOR STAIR
#35691929M
Jul 2, 2025
POP/IN-VIO
$0
May 14, 2024Construction CLASS - 2
REISSUE #35672899R. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF MY INSPECTION I OBSERVED AT THE 4TH FLOOR STAIRCASE C BY ROOM 408 DOOR NOT WORKING PROPERLY WHEN TESTED NEED TO MAKE NECESSA
#35682751J
Aug 21, 2024
POP/IN-VIO
$0
Apr 4, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED THE SMOKE DOOR ON 4TH FLOOR STAIR C BY ROOM 408 IS NOT WORKING PROPERLY.REMEDY:REPAIR AND/OR REPLACE.
#35672899R
Jun 21, 2023
POP/IN-VIO
$0
DOB (1)
IssuedViolationStatus
Apr 28, 1999CONSTRUCTION

#303GN06
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 10:44 PM ET. BBL 3015100001.