5 floors · 8 apartments · 19,863 sq ft · built 1861 · class D5 · owner of record: 121 Chambers St Llc

1open violations
$25,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 67 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 83 days
Annual
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 798 days
Next cycle year 2028

Open violations

ECB / OATH (6) · $25,000 owed
IssuedViolationHearingBalance
Dec 1, 2023Cranes and Derricks CLASS - 1
AT TIME OF INSPECTION, GC INTERSTATE INTERIORS HOISTING MECHANICAL EQUIPMENT WITH A KNUCKLE BOOM. A CRANE IS REQUIRED FOR THIS OPERATION. KNUCKLE BOOM'S CAN NOT SERVICE A JOBSITE, ONLY USED FOR MATERIAL DELIVER
#39100529L
Jul 11, 2024
IN VIOLATION
$10,000
Dec 1, 2023Construction CLASS - 1
AT TIME OF INSPECTION, WILSON MAYANCELA WAS OPERATING A KNUCKLEBOOM & HOISTING MECHANICAL EQUIPMENT WITHOUT A NYC DOB LICENSED HMO. A NYC DOB LICENSED HMO IS REQUIRED WHEN HOISTING MECHANICAL EQUIPMENT., OBTAIN
#39100533Y
Mar 11, 2027
$5,000
Feb 16, 2022Site Safety CLASS - 1
FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY BC CHAPTER 33AT TIME OF INSPECTION I REQUESTED THE FOLLOWING SIDEWALK SHED DAILY INSPECTIONS SUPPORTED SCAFFOLD DAILY INSPECTIONS INCLUDING INTERIOR STAI
#35642405K
May 19, 2022
IN VIOLATION
$1,250
Feb 16, 2022Site Safety CLASS - 1
FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY BC CHAPTER 33AT TIME OF INSPECTION I OBSERVED SUPPORTED SCAFFOLDS THROUGHOUT THE INTERIOR OF SITE.UPON REQUEST FOR MANUFACTURER'S SPECIFICATIONS,NONE WER
#35642403R
May 19, 2022
IN VIOLATION
$1,250
Feb 16, 2022Construction CLASS - 1
FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO GUARDRAILS.AT TIME OF MY INSPECTION I OBSERVED NO GUARDRAILS OR SAFETY MEASURES IN PLACE AT 3RD FLOOR AREA OPPOSITE SIDE OF S
#35642402P
May 19, 2022
IN VIOLATION
$2,500
Aug 25, 2021Construction CLASS - 2
FAILURE TO SAFEGUARD/FAILURE TO MAINTAIN SAFETY OPERATIONS.AT TIME OF INSPECTION OBSERVED ON EXP #1 OPENING LARGE ENOUGH TO ACCESS JOBSITE W/A LADDER TO TRESPASS.SITE OPEN TO PUBLIC.REMEDY:MAINTAIN SAFETY OPERA
#35490357P
Nov 18, 2021
DEFAULT
$5,000
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (1) · C 0 · B 1 · A 0
IssuedClassViolationCorrect by
Sep 1, 2009BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 200 WATT MINIMUM REQUIRED AT FRONT AREAWAYOct 6, 2009

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 2:14 PM ET. BBL 1001450010.

Look up another building