Manhattan · Block 884 · Lot 17 · 10016

120 Lexington Avenue

class V1 · owner of record: Ww Lexington, Llc

7open violations
$55,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
—no dated deadlines found

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

We couldn't find building attributes for this lot, so no deadlines are listed.

Open violations

ECB / OATH (11) · $55,000 owed
IssuedViolationHearingBalance
Oct 20, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION OF AN ACTIVE 12 STORY BUILDING CONST SITE. OBSERVED WORK CONTRARY TO THE APPROVED SSP. SSP REQUIRES CONCRETE BARRIER BARRICADE AT EXPOSURE #4; HOWEVER, PLASTIC BARRIERS WERE INSTALLED
#39560827R
Dec 24, 2026
PENDING
$1,250
Oct 16, 2026Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED WORK/STORAGE ZONE WITHOUT CHAIN-LINK FENCING ATOP JERSEY BARRIERS AS SHOWN ON APPROVED SITE SAFETY PLAN, CONTRARY TO AC 28-105.12.2, CREATING A STRUCK-BY HAZARD TO THE PUBLIC AND
#39560684Z
Dec 24, 2026
PENDING
$2,500
Oct 16, 2026Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED UNSECURED PLYWOOD FORMWORK DECKING AT THE TOPMOST WORKING DECK DURING A DEPARTMENT ISSUED 58 MPH HIGH-WIND ADVISORY, CONTRARY TO BC 3305.3.4, CREATING A HAZARD OF PLYWOOD BECOMIN
#39560687Y
Dec 24, 2026
PENDING
$10,000
Oct 16, 2026Unknown CLASS - 1
AT TIME OF INSPECTION, OBSERVED VERTICAL SAFETY NETTING NOT MAINTAINED LOOSE AND RIPPED NETTING, DURING A 58 MPH WEATHER ADVISORY, CONTRARY TO BC 3308.5, CREATING A HAZARD OF FALLING AND FLYING MATERIALS STRIKI
#39560685K
Dec 24, 2026
PENDING
$10,000
Oct 16, 2026Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED ACTIVE JOBSITE. UPON REQUEST, NO SITE SAFETY MANAGER WAS MADE AVAILABLE, CONTRARY TO BC 3310.5.2, CREATING A HAZARD DUE TO LACK OF SITE SAFETY MONITORING. STOP ALL WORK UNDER PER
#39560683R
Dec 24, 2026
PENDING
$10,000
Oct 16, 2026Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED LACK OF GUARDRAIL SYSTEMS AROUND THE ACCESS LADDER OPENING, THE ONLY ACCESS POINT TO THE TOPMOST WORKING DECK, CONTRARY TO BC 3308.7, CREATING A FALL HAZARD TO WORKERS, VISITORS,
#39560686M
Dec 24, 2026
PENDING
$5,000
Aug 7, 2026Unknown CLASS - 2
NOTE: AT THE TIME OF INSPECTION OF AN ACTIVE CONSTRUCTION SITE, I OBSERVED WORK BEING PERFORMED AT EXPOSURE #4 AT A HEIGHT EXCEEDING 48 INCHES ABOVE THE ROOF OF THE ADJOINING BUILDING WITHOUT THE REQUIRED ROOF
#39557668L
Mar 18, 2027
$2,500
Aug 7, 2026Construction CLASS - 1
NOTE: AT THE TIME OF INSPECTION OF AN ACTIVE CONSTRUCTION SITE, I OBSERVED CONSTRUCTION DUST AND SAWDUST MIGRATING FROM THE JOB SITE INTO THE PUBLIC RIGHT-OF-WAY CONTRARY TO 3306.9.3. THIS CONDITION CREATES A H
#39557667J
Mar 18, 2027
$10,000
Aug 7, 2026Construction CLASS - 2
NOTE: AT THE TIME OF INSPECTION OF AN ACTIVE CONSTRUCTION SITE, I OBSERVED A METAL BOX ATTACHED TO THE STRUCTURE. A REVIEW OF THE APPROVED SITE SAFETY PLAN DETERMINED THAT THIS INSTALLATION WAS NOT IDENTIFIED O
#39557669N
Mar 18, 2027
$1,250
Aug 7, 2026Construction CLASS - 1
NOTE: AT TIME OF INSPECTION OF AN ACTIVE SITE, I OBSERVED ONGOING CONSTRUCTION OPERATIONS, UPON REVIEWING THE DEPARTMENT RECORDS IT WAS FOUND THAT THE NEW BUILDING GENERAL CONSTRUCTION PERMIT WAS NOT ISSUED FOR
#39557666H
Mar 18, 2027
$2,500
Nov 29, 2021Construction CLASS - 1
BC3303.4.7 MATERIAL STORAGE NOT TO CODE REQUIREMENTS.NOTE AT TIME OF INSPECTION I OBSERVED MATERIAL STORAGE OVER 3' EXPOSED TO THE PUBLIC. REMEDY:COMPLY W/ CODE- ENCLOSE STORAGE
#35504890H
Sep 29, 2022
IN VIOLATION
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 20, 2026ECBConstruction: AT THE TIME OF INSPECTION OF AN ACTIVE 12 STORY BUILDING CONST SITE. OBSERVED WORK CONTRARY TO THE APPROVED SSP. SSP REQUIRES CONCRETE BARRIER BARRICADE AT EXPOSURE #4; HOWEVER, PLASTIC BARRIERS WERE INSTALLEDOpen
Oct 16, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED WORK/STORAGE ZONE WITHOUT CHAIN-LINK FENCING ATOP JERSEY BARRIERS AS SHOWN ON APPROVED SITE SAFETY PLAN, CONTRARY TO AC 28-105.12.2, CREATING A STRUCK-BY HAZARD TO THE PUBLIC ANDOpen
Oct 16, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED UNSECURED PLYWOOD FORMWORK DECKING AT THE TOPMOST WORKING DECK DURING A DEPARTMENT ISSUED 58 MPH HIGH-WIND ADVISORY, CONTRARY TO BC 3305.3.4, CREATING A HAZARD OF PLYWOOD BECOMINOpen
Oct 16, 2026ECBUnknown: AT TIME OF INSPECTION, OBSERVED VERTICAL SAFETY NETTING NOT MAINTAINED LOOSE AND RIPPED NETTING, DURING A 58 MPH WEATHER ADVISORY, CONTRARY TO BC 3308.5, CREATING A HAZARD OF FALLING AND FLYING MATERIALS STRIKIOpen
Oct 16, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED ACTIVE JOBSITE. UPON REQUEST, NO SITE SAFETY MANAGER WAS MADE AVAILABLE, CONTRARY TO BC 3310.5.2, CREATING A HAZARD DUE TO LACK OF SITE SAFETY MONITORING. STOP ALL WORK UNDER PEROpen
Oct 16, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED LACK OF GUARDRAIL SYSTEMS AROUND THE ACCESS LADDER OPENING, THE ONLY ACCESS POINT TO THE TOPMOST WORKING DECK, CONTRARY TO BC 3308.7, CREATING A FALL HAZARD TO WORKERS, VISITORS,Open
Sep 9, 2026DOB SafetyAEUHAZ: Closed
Sep 9, 2026DOB SafetyAEUHAZ: Closed
Aug 7, 2026ECBUnknown: NOTE: AT THE TIME OF INSPECTION OF AN ACTIVE CONSTRUCTION SITE, I OBSERVED WORK BEING PERFORMED AT EXPOSURE #4 AT A HEIGHT EXCEEDING 48 INCHES ABOVE THE ROOF OF THE ADJOINING BUILDING WITHOUT THE REQUIRED ROOFClosed
Aug 7, 2026ECBConstruction: NOTE: AT THE TIME OF INSPECTION OF AN ACTIVE CONSTRUCTION SITE, I OBSERVED CONSTRUCTION DUST AND SAWDUST MIGRATING FROM THE JOB SITE INTO THE PUBLIC RIGHT-OF-WAY CONTRARY TO 3306.9.3. THIS CONDITION CREATES A HClosed
Aug 7, 2026ECBConstruction: NOTE: AT THE TIME OF INSPECTION OF AN ACTIVE CONSTRUCTION SITE, I OBSERVED A METAL BOX ATTACHED TO THE STRUCTURE. A REVIEW OF THE APPROVED SITE SAFETY PLAN DETERMINED THAT THIS INSTALLATION WAS NOT IDENTIFIED OClosed
Aug 7, 2026ECBConstruction: NOTE: AT TIME OF INSPECTION OF AN ACTIVE SITE, I OBSERVED ONGOING CONSTRUCTION OPERATIONS, UPON REVIEWING THE DEPARTMENT RECORDS IT WAS FOUND THAT THE NEW BUILDING GENERAL CONSTRUCTION PERMIT WAS NOT ISSUED FORClosed

Check the agency records