Bronx · Block 2874 · Lot 98 · 10452

120 Featherbed Lane

5 floors · 28 apartments · 29,700 sq ft · built 1924 · class C7 · owner of record: Featherbed Holdings Ii Lllc

32open violations
$2,400ECB/OATH penalties owed
13HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 29,700 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 190 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 190 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1165 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-18 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1) · $2,400 owed
IssuedViolationHearingBalance
Jan 10, 2025Construction CLASS - 2
AT TIME OF MY INSPECTION I OBSERVED A 6 STORY BUILDING WITH A SIDEWALK SHED. I NOTICED THAT SIDEWALK SHED IS NOT KEPT AS PER CODE; LOOSE CROSS BRACING ON THE GROUND AND BOLTS THAT ARE UNCAPPED CREATING A SHARP
#39535847J
Mar 21, 2025
IN VIOLATION
$2,400
DOB (3)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06204
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
#25141
DOB VIOLATION - ACTIVE
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2002059
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Oct 8, 2026GHG Emissions - LL97 FTF-EN-LL97321
FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B).
Active
Jun 24, 2026GHG Emissions - LL97 FTF-EN-LL97321
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
HPD (23) · C 13 · B 9 · A 1
IssuedClassViolationCorrect by
Jun 4, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE KEY OPERATED LOCK INSTALLED AT BUILDING ENTRANCE DOOR LEADING TO 1ST STORY PUBLIC HALLJul 9, 2026
Jun 4, 2026C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT BUILDING ENTRANCE DOOR LEADING TO 1ST STORY PUBLIC HALLJun 10, 2026
Jan 22, 2026CApt 45 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 45, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''Feb 5, 2026
Dec 31, 2025CApt 54 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER EXCEEDING 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 54, 5th STORY, 1st APARTMENT FROM NORTH AT EASTJan 6, 2026
Dec 31, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO DOOR AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 5th STORYJan 14, 2026
May 28, 2025A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOORS, STAIRS, AND STAIR LANDINGS AT ALL STORIES AT PUBLIC HALLAug 31, 2025
May 27, 2025BApt 41 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK EAST WALL AND CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 41, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJul 1, 2025
May 27, 2025BApt 41 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL AND CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 41, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJul 1, 2025
Jul 29, 2024B§ 27-2005 ADM CODE PROVIDE IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTIABLE MECHANICAL HEABY DUTY LOCK AND LATCH SET AT BUILDING STREET ENTRANCE DOOR , 1st STORYSep 2, 2024
Jul 29, 2024C§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF MAGNETIC LOCKING DEVICE AT BUILDING ENTRANCE DOOR , 1st STORYAug 4, 2024
May 10, 2024BApt 41 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RETURN BUZZER/INTERCOM SYSTEM FROM BUILDING ENTRANCE TO NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 41, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , 1st SECTION FROM WEST AT NORTHJun 14, 2024
May 10, 2024B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW LINTILS AT 3RD AND 7TH WINDOW FROM EAST AT NORTH FACADE OF THE BUILDING , 4th STORYJun 14, 2024
May 6, 2024C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT NORTH AND SOUTH BULKHEAD DOORS , 5th STORYMay 20, 2024
Feb 25, 2014BApt 53 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 53, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT NORTHApr 1, 2014
Oct 3, 2013BApt 22 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 22, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTHNov 7, 2013
Jul 8, 2013BApt 24 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 24, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHAug 12, 2013
Aug 24, 1999CApt 36 · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING NORTH SOUTH EAST AND WEST WALLS 3RD STY SOUTH APT 36 SOUTHWEST ROOM ER1 718 7161852 MS TINA CABALLERO CONTROL 39816. , SECTION '' ''Sep 13, 1999
Aug 24, 1999CApt 36 · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING EAST AND NORTH WALLS 3RD STY SOUTH APT 36 FOYER CONTROL 39816. , SECTION '' ''Sep 13, 1999
Aug 24, 1999CApt 36 · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING NORTH SOUTH AND EAST WALLS STEAM RISER AND DOOR 3RD STY SOUTH APT 36 BATHROOM ER1 CONTROL 39816. , SECTION '' ''Sep 13, 1999
Aug 24, 1999CApt 36 · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING AND EAST WALL 3RD STY SOUTH APT 36 SOUTH EAST ROOM ER1 CONTROL 39816. , SECTION '' ''Sep 13, 1999
Aug 24, 1999CApt 36 · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING AND WEST WALL 3RD STY SOUTH APT 36 KITCHEN CONTROL 39816. , SECTION '' ''Sep 13, 1999
Aug 17, 1999CApt 36 · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING NORTH WALL WINDOW STOOLS DOOR SOUTH ROOM 3RD STY SOUTH APT 36 MS CABELLERO PH 718 7161852 ER1 90991 , SECTION '' ''Sep 6, 1999
Aug 17, 1999CApt 36 · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT PLASTER CEILING STEAM RISER BATHROOM 3RD STY SOUTH APT 36 SOUTH SECTION ER1 90998. , SECTION '' ''Sep 6, 1999

Issued in the last 120 days

DateSourceWhatNow
Oct 8, 2026DOB SafetyGHG Emissions - LL97: FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B).Open