13 floors · 63,967 sq ft · built 1903 · class HR · owner of record: Lemarquis Associates,
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 63,967 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 165 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 165 days | Annual filing |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $64,750 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2028 in 461 days | No Cycle 10 report on record yet |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1140 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2030) Likely applies Local Law 87 · Calendar year 2030 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 860). Agency page | Dec 31, 2030 in 1505 days | Next due 2030 |
| Annual boiler inspection (6 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-02 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 29, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED NO FIRE STOPPING AT AND HOLES IN ACCESS PANELS ALSO FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39151780L ISSUED ON 06-23-2025 FOR FAILURE TO MAINTAIN BUILDING IN CO #39198154M | Oct 8, 2026 DEFAULT | $6,280 |
| Jul 29, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION OBSERVED ELECTRICAL WIRING EXPOSED AND UNSAFE ALSO FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39151779Y ISSUED ON 06-23-2025 FOR UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUI #39198153K | Oct 8, 2026 DEFAULT | $4,030 |
| Jun 16, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS THROUGHOUT BUILDING., REPAIR AND/REPLACE #39192736P | Aug 20, 2026 DEFAULT | $12,500 |
| Jun 16, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED BLOCKED EGRESS AT ENTRANCE OF THE BUILDING., REPAIR AND/OR REPLACE #39192737R | Aug 20, 2026 DEFAULT | $4,970 |
| Jun 16, 2026 | Construction CLASS - 1 ATOI OBSERVED LACK OF SPRINKLER COVERAGE ON THE 12TH FL. THROUGHOUT BUILDING MISSING OPEN ENDED TOILET SEATS & IN BASEMENT WATER HEATER VENT IS DISCONNECTED. CONTRARY TO PC 102.3 & PC 420.3, REPAIR AND/REPLACE #39192711Z | Aug 20, 2026 DEFAULT | $12,500 |
| Mar 2, 2026 | Elevators CLASS - 1 100/L/10 IN SIDE CAR FIRE SERVICE IS NOT WORKING DEFECTIVE REPAIR. #39178790P | May 7, 2026 DEFAULT | $6,250 |
| Jun 26, 2025 | Elevators CLASS - 2 CLASS 2 ITEMS: IN-CAR COMMUNICATION INOPERATIVE. PROVIDE A NYC ELEVATOR DEVICE # IN CAR. ELIMINATE NOISE ORIGINATING FROM THE OVERHEAD SHEAVE. #39152035X | Sep 4, 2025 DEFAULT | $0 |
| Jun 26, 2025 | Elevators CLASS - 2 CLASS 2 ITEMS: IN-CAR COMMUNICATION INOPERATIVE. PROVIDE A NYC DEVICE # IN CAR. SAFETY RAILING IN CAR IS MISSING. BRAKE MAINTENANCE TAG EXPIRED. CAR NOT RESPONING TO CAR CALL FOR 12-14 FLOORS. #39152034Y | Sep 4, 2025 DEFAULT | $0 |
| Jun 23, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS AND UNPERMITTED PLASTIC ACCESS PANELS, THROUGHOUT THE #39151780L | Nov 17, 2026 PENDING | $12,500 |
| Jun 23, 2025 | Unknown CLASS - 1 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED EXPOSE FUSE BOXES AND EXPOSE WIRING IN THE SPRINKLER VALVE ROOM. LOCATED THROUGHOUT THE BU #39151779Y | Sep 25, 2025 IN VIOLATION | $0 |
| Dec 30, 2024 | Boilers CLASS - 2 FOUND LAARRS MODEL#PW0500 GAS FIRED BOILER NOT OPERABLE, (UNIT #2) REPAIR OR REPLACE UNIT #39133962N | Apr 3, 2025 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 1, 2023 | FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) FAILURE TO CORRECT SWARMP CONDITIONS #00026 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #24563 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #24564 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #24565 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #24566 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #24567 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #24568 | DOB VIOLATION - ACTIVE |
| Feb 15, 2023 | HAZARDOUS CONDITION (FACADE) CYCLE 9B UNSAFE REPORT FILED #910735 | DOB VIOLATION - ACTIVE |
| Jun 8, 2001 | ELEVATOR #9011/13830 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Sep 2, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 2, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 23, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 23, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 1, 2023 | Facades FISPFCS CYCLE 9B FAILURE TO CORRECT SWARMP CONDITIONS | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Feb 15, 2023 | Facades FISPHAZ CYCLE 9B UNSAFE REPORT FILED | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 11, 2025 | B | Apt 501 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL AND CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 501, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 16, 2025 |
| Sep 11, 2025 | C | Apt 501 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 501, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 7, 2025 |
| Aug 12, 2025 | C | Apt 501 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ROOM LOCATED AT B-ROOM 501, 5th STORY, 1st B-ROOM FROM WEST AT NORTH | Sep 7, 2025 |
| Aug 12, 2025 | B | Apt 501 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM EAST LOCATED AT B-ROOM 501, 5th STORY, 1st B-ROOM FROM WEST AT NORTH | Sep 16, 2025 |
| Aug 12, 2025 | B | Apt 501 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd ROOM FROM EAST LOCATED AT B-ROOM 501, 5th STORY, 1st B-ROOM FROM WEST AT NORTH | Sep 16, 2025 |
| Mar 20, 2025 | B | Apt 333 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH AND WEST WALLS IN THE 2nd ROOM FROM NORTH LOCATED AT B-ROOM 333, 3rd STORY, 2nd B-ROOM FROM NORTH AT EAST | Apr 24, 2025 |
| Jan 23, 2024 | C | Apt 443 · § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT LOCATED AT B-ROOM 443, 4th STORY, 1st B-ROOM FROM NORTH AT EAST , SECTION ''EAST'' | Jan 23, 2024 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Sep 2, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 2, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 1, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING FACADE WALL"S" AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION I OBSERVED AT 2, EAST ELEVATION, CRACKED COPING STONE AT ROOF LEVEL. AT EX 3, SOUTH ELEVATION, INADEQUATE A/C SUPPO | Closed |
| Jul 31, 2026 | ECB | Construction: FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION I OBSERVED AT EXPOSURE #2 EAST ELEVATION, UNSECURED OBJECTS ON WINDOW SILL AT APPX 13TH FLOOR(TOP FLOOR). THIS CONDITI | Closed |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 29, 2026 | ECB | Construction: AT TIME OF INSPECTION OBSERVED NO FIRE STOPPING AT AND HOLES IN ACCESS PANELS ALSO FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39151780L ISSUED ON 06-23-2025 FOR FAILURE TO MAINTAIN BUILDING IN CO | Open |
| Jul 29, 2026 | ECB | Unknown: AT TIME OF INSPECTION OBSERVED ELECTRICAL WIRING EXPOSED AND UNSAFE ALSO FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39151779Y ISSUED ON 06-23-2025 FOR UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUI | Open |
| Jul 23, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 23, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 9:25 PM ET. BBL 1008600074.