2 floors · 4,000 sq ft · built 1930 · class F9 · owner of record: 10-17 Jackson Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1161 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 25, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: AT REAR OF BUILDING OBSERVED BACK WALL WITH VERTICAL & HORIZONTAL CRACKS, & RIGHT SIDE WALL WITH VERTICAL & HORIZONTAL CRACKS, MISSING MORTAR JOINTS #39205627X | Dec 1, 2026 PENDING | $5,000 |
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: AT REAR OF BUILDING OBSERVED BACK WALL WITH VERTICAL & HORIZONTAL CRACKS, & RIGHT SIDE WALL WITH VERTICAL & HORIZONTAL CRACKS, MISSING MORTAR JOINTS THROUGH OUT, WALL BULGING OUTWARDS, ALSO OBSERVED APPROX. 16 TIEBACKS WITH NO PROFESSIONA #26-02299 | DOB VIOLATION - ACTIVE |
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 25, 2026 | DOB | CONSTRUCTION: FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: AT REAR OF BUILDING OBSERVED BACK WALL WITH VERTICAL & HORIZONTAL CRACKS, & RIGHT SIDE WALL WITH VERTICAL & HORIZONTAL CRACKS, MISSING MORTAR JOINTS THROUGH OUT, WALL BULGING OUTWARDS, ALSO OBSERVED APPROX. 16 TIEBACKS WITH NO PROFESSIONA | Open |
| Sep 25, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: AT REAR OF BUILDING OBSERVED BACK WALL WITH VERTICAL & HORIZONTAL CRACKS, & RIGHT SIDE WALL WITH VERTICAL & HORIZONTAL CRACKS, MISSING MORTAR JOINTS | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 12:58 AM ET. BBL 4000600004.