Brooklyn · Block 3390 · Lot 57 · 11221

1193 Hancock Street

2 floors · 2 apartments · 2,565 sq ft · built 1910 · class B2 · owner of record: 1193 Hancock Llc

22open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
303dto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 303 days
Required only if the owner doesn't live there

Open violations

ECB / OATH (6)
IssuedViolationHearingBalance
Aug 29, 2013Unknown CLASS - 1
SEC. EC 250.24C VIOLATION OF THE ELECTRICAL CODE, TECHNICAL STANDARDS.SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY. AT WATER MAIN. AT 1:55 PM OBSERVED IN BASMENT @ WATER MAIN THAT GROUNDING CLAMP
#35021477H
Mar 13, 2014
WRITTEN OFF
$0
Aug 12, 2013Unknown CLASS - 1
SEC. 27-3018I VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS METERING FOR COMMON AREAS HAS NOT BEEN PROVIDED/ILLEGAL METERING. AT 1:55PM OBSERVED THAT IN BASEMENT SEPERATE METER FOR BOILER & HALLWAY HAVE
#35021479L
Mar 3, 2014
WRITTEN OFF
$0
Aug 12, 2013Unknown CLASS - 1
ELECTRICAL WORK W/O PERMIT. ELECTRICAL WIRING OF PANELS IN BSMT,BRANCHCIRCUTS OF APTS. HALLWAY LIGHTING PRIOR TO OBTAINING PERMIT. AT 1:55PMOBSERVED THAT WIRING OF METER EQUIPT TO NEW PANELS WAS DEFECTIVE AND
#35021476X
Mar 13, 2014
WRITTEN OFF
$0
Aug 12, 2013Unknown CLASS - 1
SEC. 505.7 VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. NO MEASURING OF ENERGY CONSUMPTION BY EACH TENANT DWELLING UNIT HAS NOT BEEN PROVIDED AT 1:55PM OBSERVED IN BASEMENT THAT THERE ARE 2 METERS BEIN
#35021481K
Mar 13, 2014
WRITTEN OFF
$0
Aug 12, 2013Unknown CLASS - 1
SEC. 300.3B VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS CONDUCTORS OF THE SAME CIRCUIT NOT GROUPED. AT 1:55PM OBSERVED AT METER EQUIPT THAT NEUTRAL(CONDUCTOR) OF SAME CIRCUIT. REMEDY: COMPLY W/EC CODE.
#35021480Z
Mar 13, 2014
WRITTEN OFF
$0
Aug 12, 2013Unknown CLASS - 1
SEC. 240.53 VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS PLUG FUSES ARE IN USE NOT TAMPER PROOF. AT 1:55PM OBSERVED IN BASEMENT THATPLUG FUSES ARE IN USE & ARE NOT TAMPER PROOF. REMEDY: COMPLY W/EC CODE
#35021478J
Mar 13, 2014
WRITTEN OFF
$0
DOB (4)
IssuedViolationStatus
Nov 20, 2013FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00180
DOB VIOLATION - ACTIVE
Nov 20, 2013FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00179
DOB VIOLATION - ACTIVE
Nov 20, 2013FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00178
DOB VIOLATION - ACTIVE
Nov 20, 2013FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00176
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Nov 20, 2013AEUHAZ FTC-AEU-HAZ
Active
Nov 20, 2013AEUHAZ FTC-AEU-HAZ
Active
Nov 20, 2013AEUHAZ FTC-AEU-HAZ
Active
Nov 20, 2013AEUHAZ FTC-AEU-HAZ
Active
HPD (8) · C 0 · B 6 · A 2
IssuedClassViolationCorrect by
Aug 14, 2013AApt 1 · SECTION 27-2005 ADMIN. CODE: REFIT THE CLOSET DOORS IN THE 2nd ROOM FROM EAST LOCATED AT APT 1, 1st STORYNov 17, 2013
Aug 14, 2013BApt 1 · SECTION 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN IN THE SINK WASTE LINE IN THE KITCHEN LOCATED AT APT 1, 1st STORYSep 18, 2013
Aug 14, 2013BApt 1 · SECTION 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN THE WASH BASIN WASTE LINE IN THE BATHROOM LOCATED AT APT 1, 1st STORYSep 18, 2013
Aug 14, 2013BApt 1 · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORYSep 18, 2013
Jun 6, 2007BApt 1FL · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR BELL IN THE ENTIRE APARTMENT LOCATED AT APT 1FLJul 21, 2007
Jun 6, 2007AApt 1FL · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD TILES AT FLOOR IN THE 4th ROOM FROM NORTH LOCATED AT APT 1FLSep 19, 2007
Jun 6, 2007BApt 1FL · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1FLJul 21, 2007
Jun 6, 2007BApt 1FL · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1FLJul 21, 2007

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 2, 2026, 11:56 PM ET. BBL 3033900057.