Bronx · Block 2372 · Lot 13 · 10456

1190 Washington Avenue

6 floors · 27,272 sq ft · built 2017 · class H9 · owner of record: 1190 Washington Avenue Llc

16open violations
$26,875ECB/OATH penalties owed
1HPD class C (immediately hazardous)
178dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 57 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 27,272 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 178 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 178 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 788 days
Next cycle year 2028

Open violations

ECB / OATH (11) · $26,875 owed
IssuedViolationHearingBalance
Mar 27, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR SUMMONS 39137385K., FILE A CERTIFICATE OF CORRECTION
#39182138X
Jun 5, 2026
DEFAULT
$6,250
Feb 6, 2026Construction CLASS - 1
OBSERVED ON THE GROUND FLOOR WATER LEAKING FROM HOT WATER HEATER ONTO THE FLOOR. TEMPERATURE RELIEF VALVE DISCHARGE PIPE ON STORAGE TANK INSTALLED IMPROPERLY. IN BATHROOM NO OPEN ENDED TOILET SEAT ADDITIONALLY
#39176380N
Nov 13, 2026
PENDING
$2,500
Feb 6, 2026Construction CLASS - 1
OBSERVED GROUND FLOOR SPRINKLER HEADS OBSTRUCTED. OUTSIDE IN THE STREET, MISSING FRESH AIR COVER PLATES MISSING FIRE DEPARTMENT CONNECTIONS CAP AND NOT HAVING THE PROPER SIGNAGE FOR THE SPRINKLER SYSTEM WHICH I
#39176381P
Nov 13, 2026
PENDING
$2,500
Feb 6, 2026Elevators CLASS - 2
CLASS 2: 1. ELEVATOR DEVICE EQUIPPED WITH A 10-AMP FUSE INSTALLED IN PLACE OF REQUIRED 6-AMP FUSE IN THE CONTROLLER CIRCUIT. IMPROPER FUSE SIZING MAY DEFEAT OVERCURRENT PROTECTION AND IS NOT IN ACCORDANCE WITH
#39176305N
Sep 4, 2026
IN VIOLATION
$625
Jul 24, 2025Boilers CLASS - 1
CEASE USE A.O. SMITH GAS FIRED WATER HEATER MODEL#AT-K5U-CV, WAS INSTALLED WITH NO WORK PERMIT ON FILE, AND HAZARDOUS CONDITION THAT BOTH UNITS MISSING PRESSURE RELIEF VALVE AS REQUIRED BY MANUFACTURE. DO NOT O
#39154759K
Aug 10, 2026
DEFAULT
$12,500
Feb 4, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE OBSERVED UNPERMITTED PLASTIC ACCESS PANELS (NOT FIRE RATED).IN AN EMERGENCY THIS M
#39137385K
Jun 13, 2025
IN VIOLATION
$2,500
Jan 10, 2024Elevators CLASS - 1
59BB5 BRAKE MAINTENANCE TAG EXPIRED SINCE 9/9/22.REMEDY MUST PERFORM AND FILE FOR TEST AN MCP AND TAG BY CONTROLLER WITH DATE TEST WAS PERFORMED MUST PERFORM TEST IMMEDIATELY.
#38275506R
Mar 29, 2024
IN VIOLATION
$0
Nov 1, 2022Construction CLASS - 2
AT FIRS FLOOR, BACK YARD EXIT DOOR DOES NOT CLOSE PROPERLY WHEN INSPECTED., REPAIR/REPLACE DOOR
#39073168Y
Dec 16, 2022
IN VIOLATION
$0
Nov 1, 2022Construction CLASS - 2
-AT FIRST FLOOR MECHANICAL ROOM, CEILING/ WALLS DAMAGES DUE WATER PENETRATION/LEAKS., REPAIR AND/OR REPLACE
#39073167M
Dec 16, 2022
IN VIOLATION
$0
Nov 1, 2022Construction CLASS - 2
AT FIRST FLOOR,ELECTRICAL ROOM, CABLE PENETRATIONS THROUGH FIREPROOF WALLS WITHOUT FIRE STOPPING PROVIDED. ALSO, ON CEILING COMBUSTIBLE (PLASTIC) PANELS ARE BEING INSTALLED WITHOUT COMPLYING WITH THE FIREPROOF
#39073166K
Dec 16, 2022
IN VIOLATION
$0
May 19, 2013Construction CLASS - 2
ILLEGAL USE IN A RESIDENTIAL DISTRICT 20 VEHICLES W/O TAGS PARKED ILLEGALY IN VACANT LOT @ TIME INSPECTION. REMEDY: DISCONTINUE ILLEGAL USE.
#35014882X
Jul 5, 2013
WRITTEN OFF
$0
DOB (0)

None open.

DOB NOW Safety (4)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction
Active
Dec 8, 2025GHG Emissions - LL97 FTF-EN-LL97320
Active
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
HPD (1) · C 1 · B 0 · A 0
IssuedClassViolationCorrect by
Jul 28, 2025C§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURESJul 26, 2025

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of CorrectionOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 4, 2026, 2:14 AM ET. BBL 2023720013.

Look up another building