5.5 floors · 20,337 sq ft · built 2008 · class N2 · owner of record: The New York Foundling
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 776 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 27, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION OBSERVED IN THE 5-6 REC. ROOM LACK OF SPRINKLER COVERAGE IN THE MAIN PART OF THE ROOM. THE ROOM IS EXACTLY THE SAME AS LOWER FLOORS SPRINKLER HEAD COULD BE BURIED IN CEILING. CONTRARY #39202104N | May 11, 2027 PENDING | $1,250 |
| Aug 27, 2026 | Construction CLASS - 1 ATOI OBSERVED NEW HOT WATER HEATERS AND NEW GAS PIPING INSTALLED IN ROOF BOILER ROOM ALSO THE CHANGE OF 2 WATER HEATERS TO 4 CHECKED DOBNOW/BIS NO PERMIT ON FILE MUST FILE WITH THE DOB AND WORK COMPLETED BY A M #39202103L | May 11, 2027 PENDING | $2,500 |
| Aug 27, 2026 | Unknown CLASS - 2 FAILURE TO PROVIDE ADEQUATE GROUNDING OF ELECTRICAL SYSTEMS. OBSERVED IN THE MAIN ELECTRICAL RM AND WATER MAIN RM NO ELECTRODE GROUND ROD INSTALLED GROUND ROD MUST BE INSTALLED FOR ALTERNATE MEANS OF GROUNDING. #39202100X | May 11, 2027 PENDING | $2,400 |
| Aug 27, 2026 | Elevators CLASS - 1 CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION #39202110J | Nov 4, 2026 IN VIOLATION | $1,250 |
| Aug 27, 2026 | Unknown CLASS - 2 FAILURE TO INSTALL GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION AS REQUIRED. OBSERVED IN THE LAUNDRY ROOMS ON ALL FLOORS NO INSTALLATION OF GFCI PROTECTION FOR WASHING MACHINES. GFCI PROTECTION IS REQUIRE #39202101H | Nov 4, 2026 IN VIOLATION | $2,400 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 13, 2026 | C | Apt 502 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM EAST LOCATED AT B-ROOM 502, 5th STORY, 1st B-ROOM FROM NORTH AT EAST | Apr 11, 2026 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 27, 2026 | ECB | Construction: AT THE TIME OF INSPECTION OBSERVED IN THE 5-6 REC. ROOM LACK OF SPRINKLER COVERAGE IN THE MAIN PART OF THE ROOM. THE ROOM IS EXACTLY THE SAME AS LOWER FLOORS SPRINKLER HEAD COULD BE BURIED IN CEILING. CONTRARY | Open |
| Aug 27, 2026 | ECB | Construction: ATOI OBSERVED NEW HOT WATER HEATERS AND NEW GAS PIPING INSTALLED IN ROOF BOILER ROOM ALSO THE CHANGE OF 2 WATER HEATERS TO 4 CHECKED DOBNOW/BIS NO PERMIT ON FILE MUST FILE WITH THE DOB AND WORK COMPLETED BY A M | Open |
| Aug 27, 2026 | ECB | Unknown: FAILURE TO PROVIDE ADEQUATE GROUNDING OF ELECTRICAL SYSTEMS. OBSERVED IN THE MAIN ELECTRICAL RM AND WATER MAIN RM NO ELECTRODE GROUND ROD INSTALLED GROUND ROD MUST BE INSTALLED FOR ALTERNATE MEANS OF GROUNDING. | Open |
| Aug 27, 2026 | ECB | Elevators: CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION | Open |
| Aug 27, 2026 | ECB | Unknown: FAILURE TO INSTALL GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION AS REQUIRED. OBSERVED IN THE LAUNDRY ROOMS ON ALL FLOORS NO INSTALLATION OF GFCI PROTECTION FOR WASHING MACHINES. GFCI PROTECTION IS REQUIRE | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 16, 2026, 1:51 AM ET. BBL 5005340088.