Staten Island · Block 534 · Lot 88 · 10304

119 Tompkins Avenue

5.5 floors · 20,337 sq ft · built 2008 · class N2 · owner of record: The New York Foundling

6open violations
$9,800ECB/OATH penalties owed
1HPD class C (immediately hazardous)
776dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 776 days
Next cycle year 2028

Open violations

ECB / OATH (5) · $9,800 owed
IssuedViolationHearingBalance
Aug 27, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION OBSERVED IN THE 5-6 REC. ROOM LACK OF SPRINKLER COVERAGE IN THE MAIN PART OF THE ROOM. THE ROOM IS EXACTLY THE SAME AS LOWER FLOORS SPRINKLER HEAD COULD BE BURIED IN CEILING. CONTRARY
#39202104N
May 11, 2027
PENDING
$1,250
Aug 27, 2026Construction CLASS - 1
ATOI OBSERVED NEW HOT WATER HEATERS AND NEW GAS PIPING INSTALLED IN ROOF BOILER ROOM ALSO THE CHANGE OF 2 WATER HEATERS TO 4 CHECKED DOBNOW/BIS NO PERMIT ON FILE MUST FILE WITH THE DOB AND WORK COMPLETED BY A M
#39202103L
May 11, 2027
PENDING
$2,500
Aug 27, 2026Unknown CLASS - 2
FAILURE TO PROVIDE ADEQUATE GROUNDING OF ELECTRICAL SYSTEMS. OBSERVED IN THE MAIN ELECTRICAL RM AND WATER MAIN RM NO ELECTRODE GROUND ROD INSTALLED GROUND ROD MUST BE INSTALLED FOR ALTERNATE MEANS OF GROUNDING.
#39202100X
May 11, 2027
PENDING
$2,400
Aug 27, 2026Elevators CLASS - 1
CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION
#39202110J
Nov 4, 2026
IN VIOLATION
$1,250
Aug 27, 2026Unknown CLASS - 2
FAILURE TO INSTALL GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION AS REQUIRED. OBSERVED IN THE LAUNDRY ROOMS ON ALL FLOORS NO INSTALLATION OF GFCI PROTECTION FOR WASHING MACHINES. GFCI PROTECTION IS REQUIRE
#39202101H
Nov 4, 2026
IN VIOLATION
$2,400
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (1) · C 1 · B 0 · A 0
IssuedClassViolationCorrect by
Apr 13, 2026CApt 502 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM EAST LOCATED AT B-ROOM 502, 5th STORY, 1st B-ROOM FROM NORTH AT EASTApr 11, 2026

Issued in the last 120 days

DateSourceWhatNow
Aug 27, 2026ECBConstruction: AT THE TIME OF INSPECTION OBSERVED IN THE 5-6 REC. ROOM LACK OF SPRINKLER COVERAGE IN THE MAIN PART OF THE ROOM. THE ROOM IS EXACTLY THE SAME AS LOWER FLOORS SPRINKLER HEAD COULD BE BURIED IN CEILING. CONTRARYOpen
Aug 27, 2026ECBConstruction: ATOI OBSERVED NEW HOT WATER HEATERS AND NEW GAS PIPING INSTALLED IN ROOF BOILER ROOM ALSO THE CHANGE OF 2 WATER HEATERS TO 4 CHECKED DOBNOW/BIS NO PERMIT ON FILE MUST FILE WITH THE DOB AND WORK COMPLETED BY A MOpen
Aug 27, 2026ECBUnknown: FAILURE TO PROVIDE ADEQUATE GROUNDING OF ELECTRICAL SYSTEMS. OBSERVED IN THE MAIN ELECTRICAL RM AND WATER MAIN RM NO ELECTRODE GROUND ROD INSTALLED GROUND ROD MUST BE INSTALLED FOR ALTERNATE MEANS OF GROUNDING.Open
Aug 27, 2026ECBElevators: CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITIONOpen
Aug 27, 2026ECBUnknown: FAILURE TO INSTALL GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION AS REQUIRED. OBSERVED IN THE LAUNDRY ROOMS ON ALL FLOORS NO INSTALLATION OF GFCI PROTECTION FOR WASHING MACHINES. GFCI PROTECTION IS REQUIREOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 16, 2026, 1:51 AM ET. BBL 5005340088.