Manhattan · Block 884 · Lot 26 · 10016

119 Lexington Avenue

5 floors · 6 apartments · 8,250 sq ft · built 1920 · class S9 · owner of record: 108 Charlton Street Realty, Inc.

12open violations
$10,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
46dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 46 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 46 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 46 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 62 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 290 days
Registered through 2027-09-01
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-10 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (5) · $10,000 owed
IssuedViolationHearingBalance
Sep 14, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.2 27-954 FOR TRANSIENT YSE AT UNIT 2R AT 2 FLOOR. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY.
#35729581L
Nov 19, 2026
PENDING
$2,500
Sep 14, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER 1018.1; 27-366;BC 1021.1 BC 1006.3 FOR TRANSIENT USE AT UNIT 2R AT 2 FLOOR. REMEDY: DISCONTI
#35729580J
Nov 19, 2026
PENDING
$2,500
Sep 14, 2026Quality of Life CLASS - 2
PERMANENT DWELLING USE/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIAL PURPOSE. DEPT OF BUILDINGS RECORDS INDICATES BUILDING TO BE A CLASS A MULTIPLE DWELLING. NOTED AT UNIT 2R AT 2 FLOOR. BEEN USED/CONNECTED TO
#35729579M
Nov 19, 2026
PENDING
$2,500
Sep 14, 2026Construction CLASS - 1
BC 907.2.8. FAILURE TO PROVIDE A FIRE ALARM SYSTEM FOR TRANSIENT USE IN UNIT 2R UNIT 2 FLOOR. REMEDY: DISCONTINUE ILLEGAL USE.
#35729582N
Nov 19, 2026
PENDING
$2,500
Apr 16, 1990Public Assembly Unknown
OPERATION OF A PLACE OF ASSEMBLY WITHOUT A CURRRET PERMIT. REMEDY: OBTAIN A PA PERMIT. FAILURE TO HAVE APPROVED PA PLANS AVAILABLE FOR INSPECTION.
#34040087J
May 31, 1990
IN VIOLATION
$0
DOB (2)
IssuedViolationStatus
Nov 2, 2007CONSTRUCTION

#MTF01EM
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Jan 24, 1996CONSTRUCTION

#H02
VIOLATION UNSERVED ECB-ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Oct 21, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 21, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 21, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
HPD (1) · C 0 · B 1 · A 0
IssuedClassViolationCorrect by
Sep 1, 2009BSECTION 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION , AT PUBLIC HALL, 1st STORYOct 6, 2009

Issued in the last 120 days

DateSourceWhatNow
Oct 21, 2026DOB SafetyAEUHAZ: Open
Oct 21, 2026DOB SafetyAEUHAZ: Open
Oct 21, 2026DOB SafetyAEUHAZ: Open
Sep 14, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.2 27-954 FOR TRANSIENT YSE AT UNIT 2R AT 2 FLOOR. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY.Open
Sep 14, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER 1018.1; 27-366;BC 1021.1 BC 1006.3 FOR TRANSIENT USE AT UNIT 2R AT 2 FLOOR. REMEDY: DISCONTIOpen
Sep 14, 2026ECBQuality of Life: PERMANENT DWELLING USE/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIAL PURPOSE. DEPT OF BUILDINGS RECORDS INDICATES BUILDING TO BE A CLASS A MULTIPLE DWELLING. NOTED AT UNIT 2R AT 2 FLOOR. BEEN USED/CONNECTED TOOpen
Sep 14, 2026ECBConstruction: BC 907.2.8. FAILURE TO PROVIDE A FIRE ALARM SYSTEM FOR TRANSIENT USE IN UNIT 2R UNIT 2 FLOOR. REMEDY: DISCONTINUE ILLEGAL USE.Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 15, 2026, 2:52 AM ET. BBL 1008840026.