Queens · Block 4292 · Lot 100 · 11354

119-17 28 Avenue

3 floors · 3 apartments · 3,328 sq ft · built 1985 · class C0 · owner of record: Lin, Jessica

10open violations
$1,250ECB/OATH penalties owed
5HPD class C (immediately hazardous)
48dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 48 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 48 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 64 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 292 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1144 days
Next cycle year 2029

Open violations

ECB / OATH (2) · $1,250 owed
IssuedViolationHearingBalance
Jul 27, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT OF BUILDINGS FOR SUMMONS 39166523M, FILE A CERTIFICATE OF CORRECTION
#39197691N
Oct 6, 2026
IN VIOLATION
$1,250
Nov 10, 2025Unknown CLASS - 2
RESIDENCE CONVERTED AND OCCUPIED FROM A LEGAL 3 FAMILY TO 4 FAMILY. DOB RECORDS INDICATE AS PER C/O # Q203275 RESIDENCE IS A 3 FAMILY WITH CELLAR AS ORDINARY USE. NOW THE CELLAR LEVEL IS CONVERTED INTO A FULL C
#39166524Y
Jan 20, 2026
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Jun 14, 2001CONSTRUCTION

#07SC02
VIOLATION WORK WITHOUT PERMIT - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
HPD (7) · C 5 · B 2 · A 0
IssuedClassViolationCorrect by
Sep 29, 2015BApt 2NDFL · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2NDFL, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTNov 3, 2015
Sep 16, 2015C§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT STREET ENTRANCE DOOR TO BLDGSep 24, 2015
Mar 2, 2015C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR TO BOILER ROOM LOCKED CELLARMar 10, 2015
Mar 2, 2015C§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT STREET ENTRANCE METAL DOOR TO BLDGMar 10, 2015
Mar 2, 2015CApt 2FL · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 9; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORYMar 30, 2015
Mar 2, 2015BApt 2FL · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORYApr 6, 2015
Mar 2, 2015C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM 1ST STORY PUBLIC HALLMar 10, 2015

Issued in the last 120 days

DateSourceWhatNow
Jul 27, 2026ECBConstruction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT OF BUILDINGS FOR SUMMONS 39166523M, FILE A CERTIFICATE OF CORRECTIONClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 13, 2026, 10:46 PM ET. BBL 4042920100.

Look up another building