6 floors · 40 apartments · 26,310 sq ft · built 1920 · class C1 · owner of record: Promesa Apartments Lp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 57 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 57 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 73 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 26,310 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 178 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 178 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 301 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 788 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-14 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 12, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED AT EXP #2 NORTH-CRACKED/SPALLING STUCCO AT WINDOW SPANDRELS AND PARAPET MULTI LOC.-EXP #4 SOUTH-(1)CRACKED BRI #35730155R | Nov 20, 2026 PENDING | $5,000 |
| Oct 22, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTED:OBSERVED AT EXP 2(N. ELEV) AND EXP 4(S. ELEV) VERTICAL CRACK IN MASONRY ON THE CORNER OF EXP 1(W. ELEV) AND EXP 2, AND CORNER EXP 1 AND 4. R #35726154N | May 29, 2026 IN VIOLATION | $2,500 |
| Oct 22, 2025 | Construction CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTED:AS PERINSPECTION,OBJECTS OBSERVED ON THE FIRE ESCAPES AT EXP 1(W.ELEV)AND EXP 4(S.ELEV)AFTER PROPERTY REVIEW IT WAS REVEALED THAT ECB VIO#35716762 #35717955Z | Dec 17, 2026 PENDING | $2,500 |
| Apr 8, 2025 | Local Law CLASS - 2 FAILURE TO SUBMIT AV ACCEPTABLE REQUIRED CYCLE 7C, 8C, AND 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #913873. AGG2 HISTORY OF NO #37034439M | Oct 17, 2025 IN VIOLATION | $10,000 |
| Mar 8, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #2 NORTH (1)VERTICAL CRACKED MASONRY/STUCCO-ROOF-CRACKED/SPALLING STUCCO BULKHEAD/PARAPET MULTI LOC. REMED #35716761X | Aug 15, 2025 IN VIOLATION | $2,500 |
| Mar 8, 2025 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE: AT TIME OF INSOECTION I OBSERVED OBJECTS ON FIRE ESCAPE AT EXP #1 WEST AND EXP #4 SOUTH. REMEDY: REMOVE ALL OBJECTS FROM ALL FIRE ESCAPES. #35716762H | Aug 15, 2025 IN VIOLATION | $1,250 |
| May 28, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES. AT TIME OF INSPECTION, I OBSERVED STONE MASONRY DECOR CRACKING/DAMAGED(NEXT TO MAIN ENTRANCE) AT EXPOSURE(1) WEST ELEVATION. CRACKING PARAPET WALL(NORTHWEST #35682097Y | Dec 20, 2024 IN VIOLATION | $1,250 |
| May 28, 2024 | Construction CLASS - 1 UNLAWFUL ACTS, FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. NOTE: RESPONDENT FAILURE TO COMPLY PRIOR SUMMON #35679981H DATED(01/30/24). OBJECT BLOCKING F.E. AT TIME OF INSPECTION, I OBSERVED OBJECTS BLOCKING FI #35682098X | Aug 2, 2024 IN VIOLATION | $2,500 |
| Jan 30, 2024 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.AT TIME OF INSPECTION,OBSERVED FLOWER POTS/CONTAINERS ON THE 6TH FLOOR FIRE ESCAPE LANDING DECK AT EXPOS.1,WEST ELEVATION.REM:REMOVE OBSTRUCTION. #35679981H | Apr 5, 2024 IN VIOLATION | $625 |
| Jan 30, 2024 | Construction CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTE:RESPONDENT DOES NOT COMPLY PRIOR SUMMON#35675501L DATED(12/14/23).AT TIME OF INSPECTION,OBSERVED CRACKED STONE-DECOR NEXT TO MAIN ENTRANCE DOOR WAY #35679980X | Apr 5, 2024 IN VIOLATION | $2,500 |
| Dec 14, 2023 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES. AS NOTED EXPOSURE 1 CRACKED STONE LINTELS IN SEVERAL LOCATIONS, CRACKED STONE AROUND ENTRANCE, RUSTING METAL CORNICE AT PARAPET, OBJECTS ON FIRE E #35675501L | Mar 22, 2024 IN VIOLATION | $2,500 |
| Oct 19, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7C AND 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#813873.AGG1:PRIOR NOV 37015951H #37023196N | Mar 10, 2023 IN VIOLATION | $3,125 |
| Oct 28, 2019 | Local Law CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#813873. AGG1 PRIOR NOV#37009384J UNDER 28-302.4 #37015951H | Mar 13, 2020 IN VIOLATION | $0 |
| Mar 7, 2018 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #713873. REM: SUBMIT REQUIRED TECHNICAL REPORT. #37009384J | Sep 28, 2018 IN VIOLATION | $0 |
| Dec 28, 2015 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG FACADE & APPURTENANCE.NOTE.EXP#2 NORTH/WEST CORNER OBSERVED VERTICAL CRACK IN PARAPET.(II)EXP#2 NORTH ELEVATION PEELING PAINT/STUCCO & CRACK IN STUCCO @PARAPET LEVEL & 4TH FL L #35133886P | Feb 19, 2016 IN VIOLATION | $0 |
| Apr 1, 2015 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG WEST ELEV EXP1 DISPLACED KEYSTONE SECOND FLR NORTH EXCAVATION EXP2-VERTICAL CRACK IN MASONRY PARAPET CORNER(NORTH/WEST CORNER) DETERIORATING BRICK COATING.RUSTING ANCHORS (COUR #35095576P | May 29, 2015 IN VIOLATION | $0 |
| Sep 26, 2014 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG.WEST ELEVATION EXP1 DISPLACED KEYSTONE,FL2 MISSING KEYSTONE VERTICAL CRACK IN MASONRY.NORTH ELEVATION EXP2 HAS VERTICAL IN MASONRY.@ CORNER OF PARAPET & DETERIORATED BRICK COAT #35095250P | Nov 21, 2014 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2024 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 #01000 | DOB VIOLATION - ACTIVE |
| Feb 12, 2024 | IMMEDIATE EMERGENCY PROVIDE SIDEWALK SHED AS FOLLOWS,EXPOSURE 1 (WEST ELEVATION WASHINGTON AVE) 70 LINEAR FT #18153 | DOB VIOLATION - ACTIVE |
| Feb 24, 2017 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT #03885 | DOB VIOLATION - ACTIVE |
| Oct 1, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT #03692 | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #07773 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 3) | Active |
| Feb 22, 2024 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
| Apr 30, 2019 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019 | Active |
| Feb 24, 2017 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT | Active |
| Oct 1, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 26, 2025 | I | § 27-2091(C) ADM CODE THE PROPERTY HAS BEEN ISSUED AN ORDER TO IDENTIFY AND ADDRESS UNDERLYING CONDITIONS AND VIOLATIONS RELATED TO THE ORDER. FAILURE TO COMPLY MAY RESULT IN EXTENSIVE REPAIR WORK TO CORRECT UNDERLYING CONDITIONS AND RELATED VIOLATIONS BY HPD. CHARGES FOR REPAIR WORK DONE PURSUANT T | — |
| Oct 26, 2026 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF AIR CONDITINER AT 5TH, 4TH, 3RD AT SOUTH COURT AT FIRE ESCAPE | Nov 30, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 31, 2026 |
| Jul 27, 2026 | A | Apt 4C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 30, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 31, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 31, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 31, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 31, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 31, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 31, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 31, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NO | Aug 31, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 31, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 31, 2026 |
| Jul 27, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Aug 31, 2026 |
| Jul 27, 2026 | B | Apt 4C · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT | Aug 31, 2026 |
| Jun 3, 2026 | C | Apt 5C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN (10) SQ FT AT CEILING, NORTH, EAST, AND WEST WALLS IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18653245 ISSUED 18-FEB-26 HAS BEEN UP | Jun 29, 2026 |
| Jun 3, 2026 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCKING DEVICE AT BUILDING ENTRANCE DOOR , 1st STORY | Jun 9, 2026 |
| Apr 1, 2026 | B | Apt 1C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, WEST WALL, AND NORTH WALL IN THE FOYER LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | May 6, 2026 |
| Apr 1, 2026 | B | Apt 1C · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | May 6, 2026 |
| Apr 1, 2026 | A | Apt 1C · § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL .. IN THE BATHROOM LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 5, 2026 |
| Apr 1, 2026 | A | Apt 1C · § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE MOLD AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 5, 2026 |
| Apr 1, 2026 | B | Apt 1C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | May 6, 2026 |
| Apr 1, 2026 | B | Apt 1C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | May 6, 2026 |
| Apr 1, 2026 | B | Apt 1C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | May 6, 2026 |
| Apr 1, 2026 | B | Apt 1C · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | May 6, 2026 |
| Mar 24, 2026 | B | Apt 3A · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE DEVICE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 3A · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE DEVICE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Apr 28, 2026 |
| Mar 24, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL CEILING AT BULKHEAD AT PUBLIC HALL, 6th STORY | Apr 28, 2026 |
| Mar 17, 2026 | B | Apt 2C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, NORTH WALL, AND WEST WALL IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Apr 21, 2026 |
| Feb 19, 2026 | B | Apt 5C · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 26, 2026 |
| Feb 19, 2026 | B | Apt 5C · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET , IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 26, 2026 |
| Feb 19, 2026 | B | Apt 5C · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH/BASIN IN THE 1st BATHROOM FROM EAST LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 26, 2026 |
| Dec 29, 2025 | B | Apt 1C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE FOYER LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Feb 2, 2026 |
| Dec 29, 2025 | A | Apt 1C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE FOYER LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Apr 3, 2026 |
| Dec 29, 2025 | A | Apt 1C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE FOYER LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Apr 3, 2026 |
| Dec 18, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Dec 24, 2025 |
| Dec 18, 2025 | C | Apt 1C · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE 1st BATHROOM FROM EAST LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Dec 18, 2025 |
| Dec 18, 2025 | C | Apt 1C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Dec 24, 2025 |
| Dec 18, 2025 | C | Apt 1C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 13, 2026 |
| Dec 18, 2025 | C | Apt 1C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 13, 2026 |
| Dec 11, 2025 | C | Apt 1C · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Dec 11, 2025 |
| Dec 11, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | Dec 17, 2025 |
| Dec 11, 2025 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE AT PUBLIC HALL, 1st STORY | Jan 6, 2026 |
| Dec 9, 2025 | C | Apt 1D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10SQFT AT CLOSET SOUTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18261214 ISSUED 29-SEP-25 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRA | Jan 4, 2026 |
| Dec 8, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | Dec 14, 2025 |
| Dec 8, 2025 | C | Apt 2C · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 7, 2025 |
| Dec 2, 2025 | B | Apt 2C · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 6, 2026 |
| Dec 2, 2025 | B | Apt 2C · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THAT IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 6, 2026 |
| Nov 18, 2025 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING | Nov 24, 2025 |
| Nov 18, 2025 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HEAVY DUTY KEY LOCKING DEVICE AND ASSEMBLYS AT STREET TO VESTIBULE DOOR | Nov 24, 2025 |
| Nov 18, 2025 | B | Apt 6C · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE PIPE AT SINK IN THE KITCHEN LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 23, 2025 |
| Nov 18, 2025 | C | Apt 1A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE 3rd ROOM FROM EAST LOCATED AT APT 1A, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Nov 18, 2025 |
| Nov 18, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | Nov 24, 2025 |
| Nov 18, 2025 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH | Dec 23, 2025 |
| Nov 18, 2025 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIAL AT CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH | Dec 23, 2025 |
| Nov 18, 2025 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH | Feb 21, 2026 |
| Nov 17, 2025 | B | Apt 1B · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 22, 2025 |
| Nov 17, 2025 | B | Apt 1B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CUALKING AT AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 22, 2025 |
| Nov 17, 2025 | C | Apt 1B · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 15, 2025 |
Showing 60 of 145. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 26, 2026 | HPD B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF AIR CONDITINER AT 5TH, 4TH, 3RD AT SOUTH COURT AT FIRE ESCAPE | Open |
| Sep 12, 2026 | ECB | Construction: FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED AT EXP #2 NORTH-CRACKED/SPALLING STUCCO AT WINDOW SPANDRELS AND PARAPET MULTI LOC.-EXP #4 SOUTH-(1)CRACKED BRI | Open |
| Jul 27, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 27, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 27, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 27, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 27, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 27, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 27, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 27, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 27, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Closed |
| Jul 27, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 27, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NO | Open |
| Jul 27, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 27, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Jul 27, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Open |
| Jul 27, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 4, 2026, 9:10 PM ET. BBL 2023720011.