42 floors · 1,047,390 sq ft · built 1970 · class O4 · owner of record: Sl Green Realty Corp.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 42 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $62,500 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 94 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 1,047,390 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 163 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 163 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1138 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 999). Agency page | Dec 31, 2029 in 1138 days | Next due 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 11, 2026 | Construction CLASS - 1 RESPONDING TO AN INCIDENT WHERE A PIECE OF MARBLE PANEL FELL FROM THE ROOF LEVEL OF A 43 STORY BUILDING ONTO THE STREET BELOW CAUSING DAMAGE TO A CAR. INSPECTION REVEALED THAT THERE WAS NO ADEQUATE SAFETY MEASU #39561836N | Jan 21, 2027 PENDING | $10,000 |
| Jul 22, 2026 | Construction CLASS - 2 OBS SIDEWALK SHED INSTALLED IN A NONCONFORMING MANNER. FIELD CONDITIONS DID NOT CONFORM TO THE DOB APPROVED CONSTRUCTION DOCUMENTS. SIDEWALK SHED WAS MISSING REQUIRED BAYS, OPENINGS, TRUSSES, CROSS BRACES, AND #39556967R | Apr 13, 2027 PENDING | $1,250 |
| Jul 22, 2026 | Unknown CLASS - 2 OBSERVED CHAIN-LINK FENCE INSTALLED ALONG THE SITE PERIMETER WITHOUT A VALID DOB PERMIT AUTHORIZING THE INSTALLATION. FENCE WAS ERECTED AND MAINTAINED WITHOUT THE REQUIRED PERMIT, CONSTITUTING UNPERMITTED WORK #39556969K | Apr 13, 2027 PENDING | $1,250 |
| Jul 22, 2026 | Construction CLASS - 2 OBS SUPP. SCAFFOLD@ ROOF LEVEL INSTALLED &IN USE IN A NONCONFORMING MANNER.APPROVED PLANS INDICATED OUTRIGGERS(BIKE) ON 2 FT.&3 FT.BICYCLE BRACKETS; FIELD CONDITIONS CONSISTED OF 4 FT. 4 IN. PIPE&KNUCKLE INSTAL #39556968Z | Apr 13, 2027 PENDING | $1,250 |
| Jul 22, 2026 | Site Safety CLASS - 1 OBSERVED SUSPENDED SCAFFOLD EQUIPMENT INSTALLED AND AVAILABLE FOR USE. NONE OF THE REQUIRED DOCUMENTS WERE PROVIDED FOR THE BEE ACCESS 5X5 OUTRIGGER BEAM ASSEMBLY,OUTRIGGER (16 FT), 1,250-LB HOIST MOTORS, PENDA #39556978M | Apr 13, 2027 PENDING | $2,500 |
| Jul 22, 2026 | Construction CLASS - 2 OBS SSP DID NOT CONFORM TO THE APPROVED CONSTRUCTION DOCS& AMENDMENTS. ALTHOUGH THE PLAN PERMITTED COMBINED PHASES &REQUIRED PROTECTIONS, IT FAILED TO INDICATE SUSPENDED SCAFFOLD DROPS,ROOF SUPPORTED SCAFFOLD L #39556966P | Apr 13, 2027 PENDING | $1,250 |
| Jul 22, 2026 | Unknown CLASS - 2 3314.15.2: OBS SUSPENDED SCAFFOLD PLATFORM INSTALLED & AVAILABLE FOR USE WITH STIRRUPS POSITIONED APPROX. 6 TO 7 FT. FROM THE PLATFORM ENDS,&LESS AT SOME LOCATIONS, INSTEAD OF THE REQUIRED 8 TO 10 FT. CONFIGURA #39556977K | Apr 13, 2027 PENDING | $2,500 |
| Jul 22, 2026 | Cranes and Derricks CLASS - 1 OBSERVED SUSPENDED SCAFFOLD IN USE&READILY AVAILABLE FOR USE. THE SPECIAL RIGGER FAILED TO PERFORM A SAFE &PROPER INSPECTION. THE INSTALLATION DID NOT CONFORM TO THE APPROVED CD5 AND INCLUDED MISSING REQUIRED T #39556976Z | Apr 13, 2027 PENDING | $10,000 |
| Jul 22, 2026 | Construction CLASS - 1 OBS SUSPENDED SCAFFOLD OPERATIONS. UPON REQUEST, MANUFACTURER SPECIFICATIONS,FOR 12,50-LB MOTORS, PENDENTS,COMPONENTS WERE NOT PROVIDED. COMPLIANCE WITH THE APPROVED CD5 AND CODE COULD NOT BE VERIFIED, CREATING #39556979Y | Apr 13, 2027 PENDING | $2,500 |
| Apr 20, 2026 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #903060. REMEDY: FILE ACCEPTABLE REPORT. #37036821M | Aug 13, 2026 DEFAULT | $6,250 |
| Dec 22, 2017 | Zoning CLASS - 2 VIOLATION OF DISCRETIONARY ZONING CONDITIONS ON PRIVATELY OWNED PUBLICSPACE.NOTED:AT TIME OF INSPECTION PUBLIC PLAZA IS MISSING REQUIRED BUSINESS AMENITIES.WATER FEATURE LANDSCAPED PEDESTRIAN PLAZA:(MISSING)FOU #35311231N | Feb 22, 2018 ADMIT/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 8, 2004 | ELEVATOR #9011/107222 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #00819 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Aug 31, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 31, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 31, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 5) | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Nov 11, 2026 | ECB | Construction: RESPONDING TO AN INCIDENT WHERE A PIECE OF MARBLE PANEL FELL FROM THE ROOF LEVEL OF A 43 STORY BUILDING ONTO THE STREET BELOW CAUSING DAMAGE TO A CAR. INSPECTION REVEALED THAT THERE WAS NO ADEQUATE SAFETY MEASU | Open |
| Oct 2, 2026 | DOB | CONSTRUCTION: STRUCTURE RENDERED NON COMPLIANT DUE TO VEHICLE IMPACTING SHED. AT EXPOSURE #4 A BUS IMPACTED SHED DISPLACING THE MUDSILL APPROXIMATELY 4 INCHES AND AND BENDING 2 PIPE RAILINGS. | Closed |
| Aug 31, 2026 | DOB Safety | AEUHAZ: | Open |
| Aug 31, 2026 | DOB Safety | AEUHAZ: | Open |
| Aug 31, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 19, 2026, 2:47 PM ET. BBL 1009990029.