5 floors · 6 apartments · 5,775 sq ft · built 1902 · class S5 · owner of record: New 1804 Wash Corp.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 43 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 59 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 287 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1139 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 20, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. THE GOOSENECK LADDER SERVING THE FIRE ESCAPE AND PROVIDING ACCESS TO THE ROOF IS DISCONNECTED AT ITS BASE. CREATING STRUCTURE UNSTABLE AND UNSAFE CONDITION #39208521L | Dec 24, 2026 PENDING | $2,500 |
| Oct 20, 2026 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. SECOND MEANS OF EGRESS ACCESSIBLE FROM FIRE ESCAPE FOR APARTMENTS: 2F,3F,4F,5F HAS BEEN ELIMINATED BY BASEMENT CONSTRUCTION, NO OTHER WAY TO ESCAPE FROM REAR YAR #39208603P | Dec 24, 2026 PENDING | $2,500 |
| Oct 20, 2026 | Construction CLASS - 1 WORK WITHOUT A PERMIT. COMBING 1ST FLOOR APARTMENT WITH BASEMENT APARTMENT, REFERENCE JOB #M00750923 APPROVED BUT NOT PERMITTED. WORK HAS AFFECTED EGRESS FOR BUILDING., OBTAIN PERMIT #39208601L | Dec 24, 2026 PENDING | $2,500 |
| Oct 20, 2026 | Unknown CLASS - 2 RESIDENCE CONVERTED MAINTAINED OR OCCUPIED AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED NUMBER OF FAMILIES AUTHORIZED BY THE C OF O OR OFFICIAL DEPARTMENT RECORDS .PER DOB RECORDS AND HPD 5 LEGAL APARTMENTS #39208602N | Dec 24, 2026 PENDING | $2,500 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 29, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 2, 2026 |
| Jul 22, 2025 | C | Apt 3F · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ...HINGE IN THE ENTRANCE LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 5, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 20, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. THE GOOSENECK LADDER SERVING THE FIRE ESCAPE AND PROVIDING ACCESS TO THE ROOF IS DISCONNECTED AT ITS BASE. CREATING STRUCTURE UNSTABLE AND UNSAFE CONDITION | Open |
| Oct 20, 2026 | ECB | Construction: FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. SECOND MEANS OF EGRESS ACCESSIBLE FROM FIRE ESCAPE FOR APARTMENTS: 2F,3F,4F,5F HAS BEEN ELIMINATED BY BASEMENT CONSTRUCTION, NO OTHER WAY TO ESCAPE FROM REAR YAR | Open |
| Oct 20, 2026 | ECB | Construction: WORK WITHOUT A PERMIT. COMBING 1ST FLOOR APARTMENT WITH BASEMENT APARTMENT, REFERENCE JOB #M00750923 APPROVED BUT NOT PERMITTED. WORK HAS AFFECTED EGRESS FOR BUILDING., OBTAIN PERMIT | Open |
| Oct 20, 2026 | ECB | Unknown: RESIDENCE CONVERTED MAINTAINED OR OCCUPIED AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED NUMBER OF FAMILIES AUTHORIZED BY THE C OF O OR OFFICIAL DEPARTMENT RECORDS .PER DOB RECORDS AND HPD 5 LEGAL APARTMENTS | Open |