Bronx · Block 2430 · Lot 45 · 10456

1160 Teller Avenue

13 floors · 214,370 sq ft · built 1972 · class I6 · owner of record: 1160 Teller Snf Realty Llc

5open violations
$6,875ECB/OATH penalties owed
0HPD class C (immediately hazardous)
67dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 67 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 214,370 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 188 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 188 days
Annual filing
Energy audit and retro-commissioning (2030) Likely applies
Local Law 87 · Calendar year 2030
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2430). Agency page

Dec 31, 2030
in 1528 days
Next due 2030
Annual boiler inspection (4 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-22 (Accepted). Agency page

On file2026 reports accepted
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $313,250 in late-filing or failure-to-file penalties. Agency page

On fileCycle 10 filing on record: SAFE (2025-10-30)

Open violations

ECB / OATH (4) · $6,875 owed
IssuedViolationHearingBalance
Jun 10, 2025Elevators CLASS - 1
CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, EMAIL THE D.O.B. EIR@BUILDINGS.NYC.GOV. ELEVATOR DIVISION AT FOR A REINSPEC
#39150621J
Oct 20, 2026
$1,250
May 12, 2025Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTED:AT ROOF LEVEL OBSERVED DAMAGED GUARDRAILS THAT SERVES AS PARAPET AT ALL EXPOSURE. REMEDY: MAINTAIN EXTERIOR FACADE. TAKE SAFETY MEASURES AND
#35693633M
Jan 9, 2026
IN VIOLATION
$5,000
Jun 1, 2021Plumbing CLASS - 2
CONDENSATION DRAINAGE MISSING NEUTRALIZER AS WELL AS CHIMNEY FGC 503.9 CAT.IV APPLIANCE DISCHARGE PIPING ON RELIEF VALVE CONTRARY TO CODE/NO THREAD ALLOWED AS PER CODE PC 504.6.2 & PC 605.4; MC MISC, COMPLY WIT
#39042209J
Sep 17, 2021
ADMIT/IN-VIO
$0
Feb 8, 2019Construction CLASS - 2
EXPIRED PERMIT. NOTE AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED INPLACE WITH NO VALID PERMIT. EXPIRED 2-3-2019, RMDY: COMPLY WITH CODE RENEW PERMIT.
#35377204J
May 10, 2019
IN VIOLATION
$625
DOB (1)
IssuedViolationStatus
Jun 13, 2019ELEVATOR

#9028/629593
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 4:35 AM ET. BBL 2024300045.