Queens · Block 9554 · Lot 31 · 11419

116-09 Liberty Avenue

2 floors · 4 apartments · 6,455 sq ft · built 1950 · class K4 · owner of record: Hardyal Paul, Trustee

17open violations
$0ECB/OATH penalties owed
1HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 778 days
Next cycle year 2028
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-18 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (17) · C 1 · B 15 · A 0
IssuedClassViolationCorrect by
Nov 22, 2017I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Aug 15, 2018BApt 2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR ALL WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHSep 19, 2018
Aug 15, 2018BApt 2 · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHSep 19, 2018
Aug 15, 2018BApt 2 · § 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHSep 19, 2018
Aug 15, 2018BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTERBALANCE AT LOWER WINDOW SASH IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHSep 19, 2018
Sep 5, 2014BApt 2R · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILING THROUGHTOUT IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, APARTMENT AT NORTHOct 10, 2014
Sep 5, 2014BApt 2R · SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE BASE BOARD RADIATOR COVERS. IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, APARTMENT AT NORTHOct 10, 2014
Sep 5, 2014BApt 2R · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD AND VINYL FLOOR TILES IN THE KITCHEN. LOCATED AT APT 2R, 2nd STORY, APARTMENT AT NORTHOct 10, 2014
Sep 5, 2014CApt 2R · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW GLASS LOWER SASH IN THE NORTHWEST BEDROOM. LOCATED AT APT 2R, 2nd STORY, APARTMENT AT NORTHSep 13, 2014
Sep 5, 2014BApt 2R · SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS HANDLE BATHTUB IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, APARTMENT AT NORTHOct 10, 2014
Sep 5, 2014BSECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR ALL WALLS 1STY TO 2NDSTY. AT PUBLIC HALLOct 10, 2014
Sep 5, 2014BApt 2R · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE SINK CABINETS IN THE KITCHEN. LOCATED AT APT 2R, 2nd STORY, APARTMENT AT NORTHOct 10, 2014
Sep 5, 2014BApt 2R · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, APARTMENT AT NORTHOct 10, 2014
Jun 6, 2007BApt 2R · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING RADIATOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2R, 2nd STORYJul 24, 2007
Jun 6, 2007BSECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE STORM WINDOW FRAME FRONT WEST ROOM 2ND FLOOR APARTMENT.Jul 24, 2007
Jun 6, 2007BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL STOPPER TO BATHTUB IN BATHROOM 2ND STORY APARTMENT #2R.Jul 24, 2007
Jun 6, 2007BApt 2FL · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORYJul 24, 2007

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 12:07 PM ET. BBL 4095540031.

Look up another building