5 floors · 122,215 sq ft · built 1930 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 122,215 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 796 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5745). Agency page | Dec 31, 2035 in 3352 days | Next due 2035 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-09 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 24, 2026 | Construction CLASS - 2 RE-ISSUE #35717585K. FAILURE TO MAINTAIN BLDG. IN CODE-COMPLIANT MANNER. NOTED: THERE ARE SEVERAL WINDOWS LOCATED THROUGH OUT THE SCHOOL THAT ARE NOT CORRECTLY. SOME DON'T OPERATE AT ALL AND SEVERAL ARE SCREWED #35727557M | May 27, 2026 POP/IN-VIO | $0 |
| Apr 24, 2026 | Construction CLASS - 2 RE-ISSUE #35717584Z. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT THE CELLAR LEVEL, THERE IS A STEEL GIRDER WITH CONCRETE ENCASING WHERE THE CONCRETE IS DETERIORATING, CRACKING AND FALLING A #35727558Y | May 27, 2026 POP/IN-VIO | $0 |
| May 27, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT T. O.I. THERE ARE SEVERAL WINDOWS SCATTERED THROUGH THE SCHOOL THAT ARE NOTOPERATING CORRECTLY. SOME NOT OPERATING AT ALL. REMEDY: REPAIR/REPLACE #35717585K | Jul 7, 2025 POP/IN-VIO | $0 |
| May 27, 2025 | Construction CLASS - 2 RE-ISSUE #35682942M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT THE CELLAR LEVEL, CEILING GIRDER HAS DETERIORATING CONCRETE ENCASEMENT THAT IS FALLING OUT, CRACKING AND BROKEN WITH EXPOSED #35717584Z | Jul 7, 2025 POP/IN-VIO | $0 |
| Aug 5, 2024 | Construction CLASS - 2 REISSUE#35672943P FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT CELLAR LEVEL OBSERVED THE CONCRETE AT CEILING PART OF IT ISMISSING EXPOSING THE RE-BARS.REM:REPAIR AND/OR REPLACE. #35682942M | Oct 9, 2024 POP/IN-VIO | $0 |
| May 30, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT CELLAR LEVEL PREVIOUS PATCHING OF CONCRETE HAS STARTED CRACKING AGAIN WITH PARTS OFIT STARTING TO FALL AGAIN.REM:REPAIR AND/OR REPLACE. #35672943P | Sep 6, 2023 POP/IN-VIO | $0 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 10:32 AM ET. BBL 3057450029.