Brooklyn · Block 5745 · Lot 29 · 11219

1153 65 Street

5 floors · 122,215 sq ft · built 1930 · class W1 · owner of record: Nyc Department Of Education

6open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
186dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 122,215 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 186 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 186 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 796 days
Next cycle year 2028
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5745). Agency page

Dec 31, 2035
in 3352 days
Next due 2035
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-09 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (6)
IssuedViolationHearingBalance
Apr 24, 2026Construction CLASS - 2
RE-ISSUE #35717585K. FAILURE TO MAINTAIN BLDG. IN CODE-COMPLIANT MANNER. NOTED: THERE ARE SEVERAL WINDOWS LOCATED THROUGH OUT THE SCHOOL THAT ARE NOT CORRECTLY. SOME DON'T OPERATE AT ALL AND SEVERAL ARE SCREWED
#35727557M
May 27, 2026
POP/IN-VIO
$0
Apr 24, 2026Construction CLASS - 2
RE-ISSUE #35717584Z. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT THE CELLAR LEVEL, THERE IS A STEEL GIRDER WITH CONCRETE ENCASING WHERE THE CONCRETE IS DETERIORATING, CRACKING AND FALLING A
#35727558Y
May 27, 2026
POP/IN-VIO
$0
May 27, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT T. O.I. THERE ARE SEVERAL WINDOWS SCATTERED THROUGH THE SCHOOL THAT ARE NOTOPERATING CORRECTLY. SOME NOT OPERATING AT ALL. REMEDY: REPAIR/REPLACE
#35717585K
Jul 7, 2025
POP/IN-VIO
$0
May 27, 2025Construction CLASS - 2
RE-ISSUE #35682942M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT THE CELLAR LEVEL, CEILING GIRDER HAS DETERIORATING CONCRETE ENCASEMENT THAT IS FALLING OUT, CRACKING AND BROKEN WITH EXPOSED
#35717584Z
Jul 7, 2025
POP/IN-VIO
$0
Aug 5, 2024Construction CLASS - 2
REISSUE#35672943P FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT CELLAR LEVEL OBSERVED THE CONCRETE AT CEILING PART OF IT ISMISSING EXPOSING THE RE-BARS.REM:REPAIR AND/OR REPLACE.
#35682942M
Oct 9, 2024
POP/IN-VIO
$0
May 30, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT CELLAR LEVEL PREVIOUS PATCHING OF CONCRETE HAS STARTED CRACKING AGAIN WITH PARTS OFIT STARTING TO FALL AGAIN.REM:REPAIR AND/OR REPLACE.
#35672943P
Sep 6, 2023
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 10:32 AM ET. BBL 3057450029.