3 floors · 16,727 sq ft · built 2019 · class H3 · owner of record: 115 Ave Realty, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 429 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 10, 2026 | Construction CLASS - 1 ATOI OBSERVED LACK OF SSPRINKLER COVERAGE IN MAIN LOBBY. PER FGC 903.3.3.FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER., REPAIR AND/REPLACE #39195614K | Sep 15, 2026 IN VIOLATION | $2,500 |
| Jul 10, 2026 | Construction CLASS - 1 ATOI OBSERVED IN BASEMENT HOT WATER HEATERS WITH PVC PIPPING BEING USED ON INTAKE AND EXHAUST OF UNITS. PER FGC 903.3.3.FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER., REPAIR AND/REPLACE #39195613Z | Sep 15, 2026 IN VIOLATION | $2,500 |
| Jul 10, 2026 | Construction CLASS - 1 OBSERVED IN BASEMENT ILLEGAL LAUNDRY ROOM INSTALLED. NO PERMIT ON FILE. PER ADMINISTRATIVE CODE 28-105.1 - IT SHALL BE UNLAWFUL TO CONSTRUCT, ALTER, REPAIR, OR PERFORM WORK REGULATED BY THE CONSTRUCTION CODES W #39195612R | Sep 15, 2026 IN VIOLATION | $1,250 |
| Jul 9, 2026 | Unknown CLASS - 1 ELECTRICAL CLOSET NOT DEDICATED TO ELECTRICAL DISTRIBUTION EQUIPMENT ONLY. OBSERVED IN THE MAIN ELECTRICAL RM THE INSTALLATION OF WIFI, CAMERA ,TELEPHONE EQUIPMENT . ALL ELECTRICAL ROOMS / CLOSET SHALL ALWAYS D #39195391M | Sep 15, 2026 IN VIOLATION | $1,200 |
| Jul 9, 2026 | Boilers CLASS - 3 @HOT WATER HEATER ROOM CELLAR>WATER LEAKING FROM CONDENSATE PIPING+FLUE TERMINATION OUTSIDE IS NOT 7' ABOVE GRADE+#1 COMBUSTION AIR PIPE IS MISSING BIRD SCREEN, MAINTAIN BOILER; CORRECT VIOLATION+SUBMIT CERTIFI #39195357Z | Sep 15, 2026 IN VIOLATION | $250 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Jul 10, 2026 | ECB | Construction: ATOI OBSERVED LACK OF SSPRINKLER COVERAGE IN MAIN LOBBY. PER FGC 903.3.3.FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER., REPAIR AND/REPLACE | Closed |
| Jul 10, 2026 | ECB | Construction: ATOI OBSERVED IN BASEMENT HOT WATER HEATERS WITH PVC PIPPING BEING USED ON INTAKE AND EXHAUST OF UNITS. PER FGC 903.3.3.FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER., REPAIR AND/REPLACE | Closed |
| Jul 10, 2026 | ECB | Construction: OBSERVED IN BASEMENT ILLEGAL LAUNDRY ROOM INSTALLED. NO PERMIT ON FILE. PER ADMINISTRATIVE CODE 28-105.1 - IT SHALL BE UNLAWFUL TO CONSTRUCT, ALTER, REPAIR, OR PERFORM WORK REGULATED BY THE CONSTRUCTION CODES W | Open |
| Jul 9, 2026 | ECB | Unknown: ELECTRICAL CLOSET NOT DEDICATED TO ELECTRICAL DISTRIBUTION EQUIPMENT ONLY. OBSERVED IN THE MAIN ELECTRICAL RM THE INSTALLATION OF WIFI, CAMERA ,TELEPHONE EQUIPMENT . ALL ELECTRICAL ROOMS / CLOSET SHALL ALWAYS D | Closed |
| Jul 9, 2026 | ECB | Boilers: @HOT WATER HEATER ROOM CELLAR>WATER LEAKING FROM CONDENSATE PIPING+FLUE TERMINATION OUTSIDE IS NOT 7' ABOVE GRADE+#1 COMBUSTION AIR PIPE IS MISSING BIRD SCREEN, MAINTAIN BOILER; CORRECT VIOLATION+SUBMIT CERTIFI | Closed |
| Jul 9, 2026 | ECB | Unknown: MISCELLANEOUS VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. OBSERVED IN THE BASEMENT MAIN HOT WATER TANK RM NO INSTALLATION OF REMOTE EMERGENCY SHUT DOWN PRESENT. REMOTE SHUT DOWN IS FOR EMERGENCY OF FI | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 28, 2026, 6:10 PM ET. BBL 4123350061.