6 floors · 30,705 sq ft · built 2010 · class HR · owner of record: Southern Hospitality Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 30,705 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 797 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 5, 2026 | Construction CLASS - 2 ATOI OBSERVED ON FLOORS 1 THRU 6 MECHANICAL ROOMS HOUSING FURNACES USING PVC PIPE ON EXHAUST AND FRESH AIR VENTS. PER PC 701.9 PLASTIC PIPE. PLASTIC PIPING AND FITTINGS SHALL NOT BE USED., REPAIR AND/OR REPLACE #39206735H | Dec 18, 2026 PENDING | $1,250 |
| Oct 5, 2026 | Construction CLASS - 2 ATOI OBSERVED ON 1ST FLOOR MECHANICAL ROOM HOUSING HOT AIR FURNACE GAS FLEX USED ON GAS SUPPLY. PER FGC 411.1.1 CONNECTING APPLIANCES. RIGID METALLIC PIPE AND FITTINGS ON HEATERS AND WATER HEATERS SHALL BE CONN #39206736J | Dec 18, 2026 PENDING | $1,250 |
| Oct 5, 2026 | Elevators CLASS - 2 CLASS 2: MAINTENANCE PROGRAM MISSING, AS PER ASME A17.1 8.6.1.2. REMEDY: PROVIDE AND MAINTAIN THE REQUIRED MAINTENANCE PROGRAM. MAINTENANCE SERVICE LOG MISSING, AS PER ASME A17.1 8.6.1.4. REMEDY: PROVIDE AND MA #39206728J | Dec 18, 2026 PENDING | $625 |
| Oct 5, 2026 | Elevators CLASS - 2 MAINTENANCE PROGRAM MISSING, AS PER ASME A17.1 8.6.1.2. REMEDY: PROVIDE AND MAINTAIN THE REQUIRED MAINTENANCE PROGRAM. MAINTENANCE SERVICE LOG MISSING, AS PER ASME A17.1 8.6.1.4. REMEDY: PROVIDE AND MAINTAIN TH #39206729L | Dec 18, 2026 PENDING | $625 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 5, 2026 | ECB | Construction: ATOI OBSERVED ON FLOORS 1 THRU 6 MECHANICAL ROOMS HOUSING FURNACES USING PVC PIPE ON EXHAUST AND FRESH AIR VENTS. PER PC 701.9 PLASTIC PIPE. PLASTIC PIPING AND FITTINGS SHALL NOT BE USED., REPAIR AND/OR REPLACE | Open |
| Oct 5, 2026 | ECB | Construction: ATOI OBSERVED ON 1ST FLOOR MECHANICAL ROOM HOUSING HOT AIR FURNACE GAS FLEX USED ON GAS SUPPLY. PER FGC 411.1.1 CONNECTING APPLIANCES. RIGID METALLIC PIPE AND FITTINGS ON HEATERS AND WATER HEATERS SHALL BE CONN | Open |
| Oct 5, 2026 | ECB | Elevators: CLASS 2: MAINTENANCE PROGRAM MISSING, AS PER ASME A17.1 8.6.1.2. REMEDY: PROVIDE AND MAINTAIN THE REQUIRED MAINTENANCE PROGRAM. MAINTENANCE SERVICE LOG MISSING, AS PER ASME A17.1 8.6.1.4. REMEDY: PROVIDE AND MA | Open |
| Oct 5, 2026 | ECB | Elevators: MAINTENANCE PROGRAM MISSING, AS PER ASME A17.1 8.6.1.2. REMEDY: PROVIDE AND MAINTAIN THE REQUIRED MAINTENANCE PROGRAM. MAINTENANCE SERVICE LOG MISSING, AS PER ASME A17.1 8.6.1.4. REMEDY: PROVIDE AND MAINTAIN TH | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 7:23 PM ET. BBL 2027280034.