9 floors · 710,600 sq ft · built 1923 · class W6 · owner of record: Trustees Of Columbia University
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 47 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 710,600 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $74,250 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 830 days | Filing window not open yet |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1961). Agency page | Dec 31, 2031 in 1873 days | Next due 2031 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 28, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, (IN CONNECTION WITH DOB VIOLATION #102622CER02GD ISSUED 10/26/2022) OBSERVED ENGINEER'S REPORT REVIEWED AND ACCEPTED ON 09/19/2023 FOR VIOLATION #37023277P ISSUED ON 11/01/2022 FOR UNLAWF #39186380M | Jul 2, 2026 DEFAULT | $0 |
| Dec 30, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALLS/APPURTENANCES. AT TIME OF INSPECTION OBSERVED AT ROOF LEVEL CORNER OF EXPOSURE1/4 DECORATIVE MASONRY LIMESTONE WHERE JOINTS MISSING MORTAR., MAINTAIN EXTERIOR BUILDING WALL #39171993N | Jan 5, 2027 DEFAULT | $2,530 |
| May 9, 2024 | Construction CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. NOTE: DOB #102622LLFA01MH REQUIRED THE OWNER TO PROVIDE A PE/RA REPORT TO THE FACADE UNIT DUE TO BROKEN/DISPLACED LIME STONE PANEL AT SEVENTH STORY BY #35682021H | Jul 18, 2024 DEFAULT | $0 |
| Oct 11, 2023 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION 102622CER02GD/338253,DATED 10/26/2022.RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS.AS OF 1 #37025830K | May 16, 2024 ADMIT/IN-VIO | $0 |
| Nov 1, 2022 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION 102622CER02GD/338253,DATED 10/26/2022.RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS.AS OF 1 #37023277P | Feb 2, 2023 IN VIOLATION | $0 |
| Feb 1, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG ROOF-BULKHEAD INERIOR BRICK/MORTAR EERODED DEFECTIVE SEALANT-GENERAL NOTE DRIED RIGLETS-LEAD CRACKED. 9 FLOOR STAIR CASE STEP CRACK-EAST ELEV. EXP3 MISSIGN MASONRY VERTICAL #35133921L | Mar 17, 2016 STIPULATION/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 1, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTED AT THE T IME OF INSPECTION,I OBSERVED CRACKS/VERTICAL CRACKS ON LIMESTONE VERTI CAL COLUMNS AT ALL EXPOSURES.REMEDY:REPAIR AND/OR REPLACE #SR10901JR | DOB VIOLATION - ACTIVE |
| Sep 18, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED MULTIPLE CRACKS ON LIMESTONE VERTICAL COLUMN AT EXPOSURE 2,3 AND EXPOSURE 4 ELEVATIONS. REMEDY: REPAIR AND/OR REPLACE #SR0902NS | DOB VIOLATION - ACTIVE |
| Nov 1, 2023 | FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) FAILURE TO CORRECT SWARMP CONDITIONS #00090 | DOB VIOLATION - ACTIVE |
| Feb 20, 2023 | HAZARDOUS CONDITION (FACADE) CYCLE 9C UNSAFE REPORT FILED #910894 | DOB VIOLATION - ACTIVE |
| Oct 26, 2022 | CONSTRUCTION STRUCTURE RENDERED NON-COMPLAINT. 12FT SECTION OF EXTERIOR MASONRY NON STRUCTURAL COLUMN UNDER REPAIR ON THE 7TH FLOOR HAD TIPPED OVER AND IS WEDGED ABOVE 4TH FLOOR SETBACK AT FRONT OF THE BUILDING (EXPOSURE 1) REMAINING SECTIONS UNDER REPAIR ARE IN DANGER OF FURTHER COLLAPSE ALONG EXPOSURE 2 #ER02GD | DOB VIOLATION - ACTIVE |
| Oct 26, 2022 | CONSTRUCTION OBSERVED 12FT SECTION OF EXTERIOR NON STRUCTURAL MASONRY COLUMN ON THE 7TH FLOOR HAD TIPPED OVER DURING FACADE REPAIR WORK AND IS WEDGED ABOVE 4TH FLOOR SETBACK AT FRONT OF BUILDING. REMAINING SECTIONS OF COLUMNS UNDER REPAIR AT EXP 1 & 2 ARE IN DANGER OF COLLAPSE. #22-04029 | DOB VIOLATION - ACTIVE |
| Oct 26, 2022 | CONSTRUCTION STRUCTURE RENDERED NON-COMPLAINT -12FEET SECTION OF THE EXTERIOR MASON RY NON STRUCTURAAL COLUMN UNDER REPAIR ON THE 7TH FLOOR HAD TIPPED OVE R AND IS WEDGED ABOVE 4TH FLOOR SETBACK AT FRONT OF THE BUILDING EXP # 1 REMAINING SEFTIONS OF COLUMNS UNDER REPAIR ARE IN DANGER OF FURTHER COLAPSE ALONG EXP #CER02GD | DOB VIOLATION - ACTIVE |
| Oct 26, 2022 | CONSTRUCTION FAILURE TO MAINTAIN FACADE AND APPURTENANCES AT SOUTH ELEVATION,EXP#1 OBSERVED BROKEN/DISPLACED LIMESTONE PANEL@7TH FLOOR REMEDY:IMMEDIATELY RETAIN SERVICE OF NYS REGISTERED DESIGN PROF.TO INSPECT&EVALUATE 100% OF ALL FACADE LIMSTONES PNLS@.EXPO TO DETERMINESAFETYOF SAME&CAUSES OF FAILURE.SUBMIT REP #LLFA01MH | DOB VIOLATION - ACTIVE |
| Mar 31, 2008 | EMERGENCY POWER #NRF01072 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #01650 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #01649 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #01648 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Nov 1, 2023 | Facades FISPFCS CYCLE 9C FAILURE TO CORRECT SWARMP CONDITIONS | Active |
| Feb 20, 2023 | Facades FISPHAZ CYCLE 9C UNSAFE REPORT FILED | Active |
| Mar 31, 2008 | Emergency Power FTF-EL-ENRF | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 7, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 10, 2026 |
| Jun 12, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 15, 2025 |
| Apr 16, 2024 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 20, 2024 |
| Mar 29, 2023 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 2, 2023 |
| Mar 8, 2022 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jun 11, 2022 |
| Apr 16, 2021 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 20, 2021 |
| Jun 19, 2008 | B | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEILING TILES 12TH STY PUBLIC HALL AT SOUTH. | Jul 24, 2008 |
| Jun 19, 2008 | A | Apt 903 · D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS CEILINGS 9TH STY WEST APT 903 THROUGHOUT. LOCATED AT APT 903 | Sep 22, 2008 |
| Jun 19, 2008 | A | D26-10.01 ADM CODE REFIT EAST WINDOW 9TH STY SOUTHEAST ROOM 940. | Sep 22, 2008 |
| Jun 19, 2008 | B | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEILING TILES 5TH STY PUBLIC HALL THROUGHOUT. | Jul 24, 2008 |
| Jun 19, 2008 | A | D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS 3RD STY SOUTHEAST ROOM 340 THROUGHOUT. | Sep 22, 2008 |
| Jun 19, 2008 | B | D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASHBASIN AT 6 STY NORTHEAST ROOM 607. | Jul 24, 2008 |
| Jun 19, 2008 | B | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEILING TILES 12TH STY PUBLIC HALL AT SOUTH. | Jul 24, 2008 |
| Jun 19, 2008 | B | D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE DOOR TO 9TH STY SOUTHEAST ROOM 940. | Jul 24, 2008 |
| Jun 19, 2008 | B | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEILING TILES AT 5TH STY PUBLIC HALL THROUGHOUT. | Jul 24, 2008 |
| Jun 19, 2008 | A | D26-10.01 ADM CODE REFIT BULKHEAD DOOR AT ROOF. | Sep 22, 2008 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |