Bronx · Block 2718 · Lot 21 · 10459

1144 Tiffany Street

8 floors · 54 apartments · 62,890 sq ft · built 2010 · class D1 · owner of record: Nyc Housing Development Corp

61open violations
$5,030ECB/OATH penalties owed
10HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 59 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 59 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-09 (Accepted). Agency page

Dec 31, 2026
in 59 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 75 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 62,890 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 180 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 180 days
Annual filing
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 476 days
No Cycle 10 report on record yet
Energy audit and retro-commissioning (2028) Likely applies
Local Law 87 · Calendar year 2028
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2718). Agency page

Dec 31, 2028
in 790 days
Next due 2028
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1155 days
Next cycle year 2029

Open violations

ECB / OATH (4) · $5,030 owed
IssuedViolationHearingBalance
Aug 5, 2026Plumbing CLASS - 2
FOUND 7 OUT OF 20 EXHAUST UNITS ON ROOF NOT OPERABLE.; MISC, COMPLY WITH NOTICE OF VIOLATION; REPAIR OR REPLACE EXHAUST UNITS.
#39199182Y
Oct 16, 2026
DEFAULT
$1,280
Apr 28, 2026Elevators CLASS - 2
1) SECURE LOBBY HALL BUTTON STATION (DAMAGED). 2) DAMAGED ACCESS KEY SWITCH IN LOBBY (REPAIR/REPLACE). 3) IN-CAR COMMUNICATION INOPERATIVE. 4) EXPIRED BRAKE TAG.
#39186409R
Jul 31, 2026
DEFAULT
$3,125
Sep 11, 2025Elevators CLASS - 2
CLASS 2 ITEMS: PERMANENTLY SECURE LOBBY HALL BUTTON PLATE. CAR DOOR MAKES SCRAPING SOUND AT THE BOTTOM, ADJUST DOOR TRAVELLING. HAND RAIL LOOSE, SECURE. MISSING BRAILLE TAGS, PROVIDE AS NEEDED.
#39160133J
Nov 21, 2025
STIPULATION/IN-VIO
$0
Dec 16, 2024Elevators CLASS - 2
RESTORE SERVICE TO THIS DEVICE.
#39132967H
Dec 29, 2025
IN VIOLATION
$625
DOB (9)
IssuedViolationStatus
Nov 1, 2023FAILURE TO CORRECT SWARMP CONDITIONS (FACADE)
FAILURE TO CORRECT SWARMP CONDITIONS
#00022
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#21982
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#21983
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#21984
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#41860
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#41861
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#24638
DOB VIOLATION - ACTIVE
Sep 6, 2019(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
#08332
DOB VIOLATION - ACTIVE
Sep 6, 2019(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
#08333
DOB VIOLATION - ACTIVE
DOB NOW Safety (9)
IssuedViolationStatus
Nov 1, 2023Facades FISPFCS
CYCLE 9B FAILURE TO CORRECT SWARMP CONDITIONS
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Sep 6, 2019Elevators ACC1
Active
Sep 6, 2019Elevators ACC1
Active
HPD (40) · C 10 · B 24 · A 6
IssuedClassViolationCorrect by
Oct 29, 2026BApt 2F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTHDec 3, 2026
Oct 29, 2026BApt 2F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTHDec 3, 2026
Oct 29, 2026BApt 2F · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTHDec 3, 2026
Oct 29, 2026BApt 2F · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTHDec 3, 2026
Oct 26, 2026BApt 4E · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SNov 30, 2026
Oct 26, 2026CApt 4E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''EAST''Nov 21, 2026
Oct 26, 2026BApt 4E · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECNov 30, 2026
Oct 26, 2026CApt 4E · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''EAST''Nov 9, 2026
Oct 20, 2026A§ 27-2042 ADM CODE PROVIDE A MIRROR IN SELF-SERVICE ELEVATOR ARRANGED SO AS TO ENABLE A PERSON ENTERING, TO VIEW INSIDE OF ELEVATOR NUMBER ID# 2P11317Jan 23, 2027
Sep 21, 2026CApt 2E · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET AT BATHTUB IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTSep 27, 2026
Sep 18, 2026BApt 2E · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT WASTELINE AT BATHTUB IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 23, 2026
Sep 16, 2026AApt 2E · § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE STAGNANT WASTE WATER OF CLOGGED WASTE LINES FROM WATER CLOSETS IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTDec 20, 2026
Jun 22, 2026A§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMASep 25, 2026
Jun 22, 2026A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYSep 25, 2026
Dec 10, 2025BApt 4E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RADIATOR AT SOUTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 4E, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTHJan 14, 2026
Nov 20, 2025BApt 3C · 28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM ANDec 25, 2025
Jul 29, 2025CApt 5E · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGE IN THE ENTRANCE LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTAug 12, 2025
Jul 29, 2025CApt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTAug 24, 2025
Jun 27, 2025BApt 5E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE 1ST WINDOW LOWER SASH SPRING BALANCE AT WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 1, 2025
Jun 27, 2025BApt 5E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZING THE BATHTUB IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 1, 2025
Jun 27, 2025BApt 5E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WASHBASIN WOOD BASE AT EAST WALL IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 1, 2025
Jun 27, 2025BApt 5E · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT WASHBASIN WASTELINE IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 1, 2025
Jun 27, 2025BApt 5E · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASHBASIN SOUTH WALL IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 1, 2025
Feb 10, 2025CApt 6A · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHFeb 16, 2025
Feb 10, 2025CApt 6A · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHFeb 16, 2025
Feb 10, 2025CApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEING IN THE 3rd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHFeb 16, 2025
Feb 10, 2025CApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHFeb 16, 2025
Feb 10, 2025BApt 6A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH 2ND WINDOW AT NORTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHMar 17, 2025
Feb 10, 2025BApt 6A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH 1ST WINDOW AT NORTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHMar 17, 2025
Feb 10, 2025BApt 6A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM AT CEILING IN THE KITCHEN LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHMar 17, 2025
Feb 23, 2024CApt 4E · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ...HINGES IN THE ENTRANCE LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHMar 8, 2024
Dec 13, 2022BApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTJan 17, 2023
Oct 8, 2021AApt 5F · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 5F, 5th STORY, 3rd APARTMENT FROM SOUTH AT WESTJan 11, 2022
Oct 8, 2021AApt 5F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUT AND CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 5F, 5th STORY, 3rd APARTMENT FROM SOUTH AT WESTJan 11, 2022
May 2, 2019BApt 5B · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL BUZZER, INTERCOM. IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM WEST AT NORTHJun 6, 2019
Feb 27, 2018BApt 5B · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM WEST AT NORTHApr 3, 2018
Apr 10, 2017BApt 5F · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTHMay 15, 2017
Aug 15, 2016BApt 6H · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 6H, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTSep 19, 2016
Aug 15, 2016BApt 6H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6H, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTSep 19, 2016
Mar 23, 2016BApt 5B · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL /BUZZER /INTERCOM SYSTEMFROM BUILDING FRONT TO APT 5B LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTApr 27, 2016

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTHOpen
Oct 29, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTHOpen
Oct 29, 2026HPD B§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTHOpen
Oct 29, 2026HPD B§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTHOpen
Oct 26, 2026HPD B§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SOpen
Oct 26, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''EAST''Open
Oct 26, 2026HPD B§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECOpen
Oct 26, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''EAST''Open
Oct 20, 2026HPD A§ 27-2042 ADM CODE PROVIDE A MIRROR IN SELF-SERVICE ELEVATOR ARRANGED SO AS TO ENABLE A PERSON ENTERING, TO VIEW INSIDE OF ELEVATOR NUMBER ID# 2P11317Open
Sep 21, 2026HPD C§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET AT BATHTUB IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Sep 18, 2026HPD B§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT WASTELINE AT BATHTUB IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Sep 16, 2026HPD A§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE STAGNANT WASTE WATER OF CLOGGED WASTE LINES FROM WATER CLOSETS IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Aug 5, 2026ECBPlumbing: FOUND 7 OUT OF 20 EXHAUST UNITS ON ROOF NOT OPERABLE.; MISC, COMPLY WITH NOTICE OF VIOLATION; REPAIR OR REPLACE EXHAUST UNITS.Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 2, 2026, 3:45 AM ET. BBL 2027180021.

Look up another building