6 floors · 62 apartments · 75,000 sq ft · built 1959 · class D1 · owner of record: 1144 Pelham Parkway Llc
Some city systems didn't answer just now (hpd). The numbers below may be incomplete; try again in a few minutes.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 45 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-10-27 (Accepted). Agency page | Dec 31, 2026 in 45 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 61 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 75,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 166 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 166 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 289 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 410 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2030) Likely applies Local Law 87 · Calendar year 2030 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 4310). Agency page | Dec 31, 2030 in 1506 days | Next due 2030 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 24, 2026 | Elevators CLASS - 1 FAILURE TO MAINTAIN ELEVATOR SYSTEM AS PER BC3001.2 & 27-987 REMEDY: CLEAN ENTIRE DEVICE. AFTER AN INSPECTION THE FOLLOWING CLASS 1 VIOLATION WERE FOUND: EMERGENCY COMMUNICATION DEVICE INOPERATIVE, CREATING A H #39201535K | Oct 30, 2026 DEFAULT | $1,280 |
| Aug 4, 2026 | Elevators CLASS - 1 CLASS 1(CU):FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION,DOOR ZONE RESTICTOR MISSING PLUNGER/INOPERATIVE REPAIR.CLASS 2:CAR TOP LI #39198964Y | Oct 16, 2026 IN VIOLATION | $1,250 |
| Jul 10, 2026 | Construction CLASS - 1 ATOI, OBSERVE UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER.B OBSERVE INSIDE UNIT 3K ELECTRICAL WORK 100% COMPLETED UNDER SWO UNDER COMPLAINT 2378534,, COMPLY WITH STOP WORK ORDER #39195720Y | Mar 12, 2027 PENDING | $10,000 |
| Oct 10, 2025 | Elevators CLASS - 1 CLASS 1 CEASE USE ITEM: DOOR LOCK MONITORING SYSTEM NOT INSTALLED ON THIS DEVICE. DLM IS MANDATORY FOR AUTOMATIC PASSENGER ELEVATORS IN NYC. THIS REQUIREMENT CAME FROM APPENDIX K3, RULE 3.10.12 (ASME A17.3-2002 #39163421H | Dec 19, 2025 DEFAULT | $6,250 |
| Jun 10, 2024 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39019302Z ISSUED ON 03/09/20 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE TO MAINTAIN., C #39116407J | Aug 16, 2024 DEFAULT | $6,250 |
| Jun 6, 2024 | Elevators CLASS - 1 RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION OF A SINGLE CAR BUILDING, VIOLATION WAS ISSUED FOR THE FOLLOWING, NO DLM INSTALLED IN CONTROLLER, REMEDY; FILE APPLICATION WITH NYCDOB INSTALL DEVICE THEN #39116177N | Aug 16, 2024 DEFAULT | $12,500 |
| Apr 11, 2024 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #908610. REMEDY: SUBMIT ACCEPTABLE REQU #37027980P | Aug 23, 2024 IN VIOLATION | $1,250 |
| Mar 6, 2024 | Construction CLASS - 2 OBSERVED CRACKED EXTERIOR CEMENT WALL AT EXPOSURE #3 ON LEFT SIDE OF THE REAR DRIVEWAY MEASURING APPROXIMATELY 9 FEET VERTICAL HEIGHT BY 1/2 INCH WIDE. THE CRACK WAS PREVIOUSLY REPAIRED WITH STUCCO / MASONRY MA #39107915L | May 17, 2024 ADMIT/IN-VIO | $0 |
| Feb 22, 2024 | Elevators CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED IN APPENDIX K OF THE 2014 BUILDINGS CODE. REMEDY INSTALL DLM , FILE AND PERFORM TEST WITH NYC DOB; REPAIR EMERGECY PHONE IN ELEVATOR; REPAIR DOOR REST #39106674P | Jun 7, 2024 DEFAULT | $12,500 |
| Dec 29, 2023 | Construction CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS#39019302Z ISSUED ON 03/09/20 AND FAILED TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH #39102420R | Mar 15, 2024 DEFAULT | $6,250 |
| Nov 27, 2023 | Unknown CLASS - 1 FOR NEWLY INSTALLED ELECTRICAL PIPE WORK IN HOLE @ EXPOSURE 4 SERVICE ENTRANCE INTERIOR ROOM LEFT SIDE. HOLE IS APPROXIMATELY 15 INCHES DEEP BY 12 FEET LENGTH X2 FEET WIDE ALSO ELECTRICAL PIPE RUNNING FROM WALL #39100155X | Jan 13, 2026 IN VIOLATION | $800 |
| Nov 3, 2023 | Construction CLASS - 1 TAMPERED WITH, REMOVED, OR DEFACED A WRITTEN POSTED STOP WORK ORDER. I OBSERVED THE PARTIAL STOP WORK ORDER STICKER #35667230Z ISSUED 10/17/2023 BY BADGE #2868 WAS REMOVED FROM THE WALL NEXT TO THE INTERCOM, CO #39098742K | Jan 19, 2024 ADMIT/IN-VIO | $0 |
| Oct 23, 2023 | Elevators CLASS - 1 RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION VIOLATION WAS ISSUED, CEASE USE FOR ALTERED CAR DOOR RESTRICTOR TO MAKE IT NOT WORKING, REMEDY; REPAIR THEN CONTACT NYCDOB FOR RESTORE TO SERVICE RE-INSPE #39097718X | Dec 29, 2023 ADMIT/IN-VIO | $0 |
| Oct 17, 2023 | Unknown CLASS - 1 ELECTRICAL WORK WITHOUT A PERMIT. NOTE: AT TIME OF INSPECTION OF A 6 STORY BUILDING I OBSERVED ON APT #3K SEVERAL ELECTRICAL FEATURES REMOVED AND COPPED FROM KITCHEN AREA, UP ON REVIEW OF THE DEPARTMENT RECORDS #35667230Z | Dec 29, 2023 ADMIT/IN-VIO | $0 |
| May 11, 2023 | Elevators CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED IN APPENDIX K OF THE 2014 BUILDING CODE; REMEDY INSTALL DLM, FILE AND PERFORM TEST WITH NYC DOB; REPAIR PHONE IN ELEVATOR #39086047K | Jul 21, 2023 ADMIT/IN-VIO | $0 |
| Jul 28, 2022 | Elevators CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. FILE APPLICATION INSTALL DLM AND PERFOR #39066896R | Sep 16, 2022 ADMIT/IN-VIO | $0 |
| Mar 13, 2022 | Elevators CLASS - 1 OUT OF SERVICE #39058046K | Jun 17, 2022 ADMIT/IN-VIO | $0 |
| Mar 9, 2020 | Construction CLASS - 1 OBSERVED LOOSE PLYWOOD BOARDS ACROSS THE FLOOR, COVERING MISSING TILES AND/OR COVERING AN UNFINISHED WORK WITHIN THE FLOOR. LOOSE PLYWOOD BOARDS ARE A HAZARD OF TRIPPING AND FALLING CONDITIONS FOR RESIDENTS APP #39019302Z | Dec 10, 2021 IN VIOLATION | $0 |
| Feb 22, 2007 | Construction Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG-HAZARDOUS.1-CRACKS IN FOUNDATION WALL-SOUTHSIDE.2-IMPROPERLY SUPPORTING AIR CONDITIONERS(VARIOUS LOCAT ION)3-LOOSE ITEMS ON FIRE ESCAPES-VARIOUS LOCATIONS.4-CRACKED BRICK #34559394K | Apr 20, 2007 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #07851 | DOB VIOLATION - ACTIVE |
| Apr 22, 2023 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022) #00767 | DOB VIOLATION - ACTIVE |
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #00965 | DOB VIOLATION - ACTIVE |
| Aug 21, 2022 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2021) #00015 | DOB VIOLATION - ACTIVE |
| Jun 20, 2021 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2020 #10284 | DOB VIOLATION - ACTIVE |
| Sep 2, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #02643 | DOB VIOLATION - ACTIVE |
| May 2, 2017 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00545 | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #07731 | DOB VIOLATION - ACTIVE |
| Aug 30, 2013 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012 #00973 | DOB VIOLATION - ACTIVE |
| Jan 19, 2007 | LOCAL LAW 62/91 - BOILERS #07209 | DOB VIOLATION - ACTIVE |
| Apr 10, 1995 | ELEVATOR #1445C02 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 6, 2026 | Energy Grade - LL33 FTP-EN-EGRDEA FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3 | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Apr 22, 2023 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Feb 22, 2023 | Facades FISPNRF CYCLE 9B NO REPORT FILED | Active |
| Aug 21, 2022 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Jun 20, 2021 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Sep 2, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 31, 2019 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018 | Active |
| May 2, 2017 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
| Aug 30, 2013 | Facades FISPNRF FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012 | Active |
| Jan 19, 2007 | Boiler LL6291 | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 24, 2026 | ECB | Elevators: FAILURE TO MAINTAIN ELEVATOR SYSTEM AS PER BC3001.2 & 27-987 REMEDY: CLEAN ENTIRE DEVICE. AFTER AN INSPECTION THE FOLLOWING CLASS 1 VIOLATION WERE FOUND: EMERGENCY COMMUNICATION DEVICE INOPERATIVE, CREATING A H | Open |
| Aug 4, 2026 | ECB | Elevators: CLASS 1(CU):FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION,DOOR ZONE RESTICTOR MISSING PLUNGER/INOPERATIVE REPAIR.CLASS 2:CAR TOP LI | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 16, 2026, 3:26 PM ET. BBL 2043100001.