7 floors · 47 apartments · 24,075 sq ft · built 2025 · class D1 · owner of record: 1143 Hoe Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | Feb 21, 2027 in 118 days | No Cycle 10 report on record yet |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 797 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 11, 2026 | Construction CLASS - 2 I OBSERVED PLASTIC BARRIERS INSTALLED ON THE ROADWAY AT EXP1 NOT IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. THE BARRIERS WERE NOT INTERLOCKING AND NOT FILLED WITH WATER OR SAND, AND COULD BE EASILY DISPLAC #39555367Z | Mar 25, 2027 | $1,250 |
| Jun 8, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED WORKER ON STREET LEVEL CUTTING A PIPE WITH A GRINDER PRODUCING SPARKS. UPON REQUESTING TO SPEAK WITH FIRE WATCH LICENSE HOLDER. WORKERS SAID THERE IS NO ONE WITH FIRE WATCH LICENS #39555231J | Mar 1, 2027 | $2,500 |
| Mar 27, 2026 | Unknown CLASS - 2 AT THE TIME OF INSPECTION, WORKERS WERE OBSERVED ON PIPE SCAFFOLDING INSTALLING STUCCO/STYROFOAM. EXCESSIVE STUCCO RESIDUE AND STYROFOAM DEBRIS WERE AIRBORNE AND SETTLING ON VEHICLES AND THE STREET, POSING A HE #39552300K | Jun 1, 2027 DEFAULT | $5,000 |
| Mar 27, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OF A PROPOSED 7-STORY NEW BUILDING, WORKERS WERE OBSERVED ON PIPE SCAFFOLDING AT EXPOSURE 3 INSTALLING STUCCO/STYROFOAM ON MULTIPLE LEVELS. REVIEW OF APPROVED DRAWINGS ALLOWS ONLY ONE MAIN #39552299M | Jun 1, 2027 DEFAULT | $6,250 |
| Jan 20, 2026 | Unknown CLASS - 2 3310.8.4- OBSERVED ACTIVE JOBSITE WITH MULTIPLE UNSAFE CONDITIONS. CONCRETE POUR W/OUT ESCAPE HATCH, INADEQUATE STREET OPERATIONS, NO DESIGN DRAWINGS FOR USE OF TARP AND JOBSITE W/OUT HORIZONTAL NETTING OR ALTE #39549351N | Mar 11, 2027 | $2,500 |
| Jan 20, 2026 | Unknown CLASS - 2 3308.6.1.1- OBSERVED ONGOING CONCRETE POUR TAKING PLACE ON 7TH FL OF JOBSITE. NO HORIZONTAL NETTING OR ALTERNATE MEANS OF PROTECTION HAS BEEN PROVIDED AT EXPOSURES 1&4 DURING THE COURSE OF CONSTRUCTION AS REQU #39549343N | Aug 28, 2026 DEFAULT | $5,000 |
| Jan 20, 2026 | Unknown CLASS - 2 3307.1- OBSERVED STREET OPERATIONS OF ACTIVE CONCRETE POUR. CONCRETE PUMP OUTRIGGERS OCCUPY PEDESTRIAN SIDEWALK WITH/OUT FULL CLOSURE, FLAGGERS AND SIGNS. CONCRETE TRUCKS ARE NOT FULLY ENCLOSED AND PROTECTED FR #39549344P | Aug 28, 2026 DEFAULT | $5,000 |
| Jan 20, 2026 | Unknown CLASS - 2 3301.6.2- OBSERVED TARP IN USE TO ENCLOSE 6TH FL OF JOBSITE TO PRESERVE THE HEAT FROM PORTABLE HEATERS DURING CONCRETE POUR. UPON REQUEST FOR DESIGNED DRAWINGS FOR THE INSTALLATION OF SAID TARP, NONE WERE PROVI #39549348M | Aug 28, 2026 DEFAULT | $5,000 |
| Jan 20, 2026 | Unknown CLASS - 2 3303.6 ESCAPE HATCH- OBSERVED ONGOING CONCRETE POUR ON 7TH FLOOR OF JOBSITE. PORTABLE HEATERS ARE PROVIDED ON 6TH FLOOR BENEATH WORK DECK. NO ESCAPE HATCH HAS BEEN PROVIDED FOR WORKERS. STOP ALL CONCRETE OPERAT #39549342L | Aug 28, 2026 DEFAULT | $5,000 |
| Jan 20, 2026 | Unknown CLASS - 2 3307.6.4.2.2 STORAGE- OBSERVED SIDEWALK SHED INSTALLED AT EXPOSURE1 OF JOBSITE PERIMETER. THE SIDEWALK SHED HAS LARGE AMOUNTS OF MATERIALS STORAGE AND DEBRIS. UPON REVIEW OF PROVIDED APPROVED DESIGNED PLANS, TH #39549349Y | Mar 2, 2027 | $2,500 |
| Jan 20, 2026 | Construction CLASS - 2 CONCRETE POUR TAKING PLACE ON 7TH FL OF JOBSITE. ON 6TH FL THERE IS A LARGE ABUNDANCE OF MATERIALS & DEBRIS THROUGHOUT ENTIRE FLOOR. EGRESS OBSTRUCTED AND THERE ARE PORTABLE DEISEAL FUELED HEATERS THAT CAN CAUS #39549345R | Aug 28, 2026 DEFAULT | $5,000 |
| Dec 20, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED STREET BARRIER NOT FILLED AND PROPERLY CONNECTED. BARRIER WAS FALLING INTO STREET. FAILURE TO MAINTAIN AND SECURE REQUIRED PUBLIC PROTECTION CREATED RISK OF BARRIER DISPLACEMENT #39548203R | Jun 1, 2027 DEFAULT | $6,250 |
| Dec 20, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED PARAPET INFORMATION PANEL MISSING REQUIRED INFORMATION. FAILURE TO MAINTAIN COMPLETE AND LEGIBLE PANEL PREVENTS PUBLIC IDENTIFICATION OF RESPONSIBLE PARTIES AND PRO #39548202P | Jun 1, 2027 DEFAULT | $3,125 |
| Dec 12, 2025 | Unknown CLASS - 1 AT TIME OF INSPECTION, OBSERVED ACTIVE CONSTRUCTION WORK WITHOUT PRE-SHIFT SAFETY MEETING LOGS AVAILABLE FOR REVIEW.CONTRARY TO CODE (3301.12.2 AND 3301.7) FAILURE TO CONDUCT AND DOCUMENT REQUIRED PRE-SHIFT ME #39547922Z | Sep 17, 2026 IN VIOLATION | $5,000 |
| Dec 12, 2025 | Unknown CLASS - 1 AT THE TIME OF INSPECTION OF A PROPOSED 7-STORY NEW BUILDING AT FOUNDATION PHASE, ACTIVE SITE AND FRAMING 1-ST FLOOR DECK AND WORKERS TAKEN IN MATERIALS INSIDE JOBSITE, UPON REQUESTING ORIENTATION FORM SSC AND #39547918X | Sep 17, 2026 IN VIOLATION | $5,000 |
| Dec 12, 2025 | Unknown CLASS - 2 AT TIME OF INSPECTION OF A PROPOSED 7 STORY NEW BUILDING, ACTIVE SITE I OBSERVED INADEQUATE JERSEY BARRIERS NOT PROPERLY ENCLOSED NOT FILLED WITH SAND OR WATER AS PER DOT RULES AND REGULATIONS 3307.1 MAINTAIN I #39547917Y | Sep 17, 2026 IN VIOLATION | $2,500 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 9:03 PM ET. BBL 2027450044.