3 floors · 40,590 sq ft · built 1984 · class W2 · owner of record: Allen Christian School
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 40,590 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 431 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 28, 2026 | Construction CLASS - 2 REISSUE ON ECB#35725540R EMERGENCY SIGNS AT ELEVATOR CALL STATIONS MISSING DEFECTIVE OR NON-COMPLIANT WITH SECTION REQUIREMENTS.NOTED:MISSING EMERGENCY SIGNS MAP AT ELEVATOR BANK ON 2ND FLOOR BY STAIR A AND C,A #35732052N | Jul 15, 2026 POP/IN-VIO | $0 |
| May 28, 2026 | Construction CLASS - 2 REISSUE ON ECB#35725541Z EXIT DOOR NOT SELF CLOSING.NOTED:EMERGENCY EXTERIOR EXIT DOORS NOT SELF-CLOSING DUE TO BINDING,MISSING AND/OR FAULTY HARDWARE ON EMERGENCY EXTERIOR EXIT DOOR AT EXIT 5 1ST FL,EXIT 6 1ST #35732051L | Jul 15, 2026 POP/IN-VIO | $0 |
| May 28, 2026 | Construction CLASS - 2 REISSUE ON ECB#35725542K FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FIRE RATED CLASSROOMS AND SMOKE DOORS NOT SELF-CLOSING DUE TO BINDING MISSING AND OR FAULTY HARDWARE ON CLASSROOMS 308,303,30 #35732050J | Jul 15, 2026 POP/IN-VIO | $0 |
| Oct 2, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: SMOKE DOORS NOT SELF-CLOSING FROM BINDING OR HARDWARE INCLUDING CLASSROOMS. CLASSROOM 303, 307, 308, 312, 212, 206, 204, 108, ELEVATOR BANK CELLAR, #35725542K | Oct 27, 2025 POP/IN-VIO | $0 |
| Oct 2, 2025 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. NOTED: EMERGENCY EXIT DOORS NOT SELF-CLOSING AT EXIT 2 AND 5 1ST FL. REMEDY: REPAIR/REPLACE DOOR. #35725541Z | Oct 27, 2025 POP/IN-VIO | $0 |
| Oct 2, 2025 | Construction CLASS - 2 EMERGENCY SIGNS AT ELEVATOR CALL STATIONS MISSING DEFECTIVE OR NON-COMPLIANT WITH SECTION REQUIREMENTS. NOTED: MISSING EMERGENCY SIGNS AT ELEVATOR BANK B 1ST FL, B CELLAR, A CELLAR, 3RD FL AND 2ND FL ELEVATOR B #35725540R | Oct 27, 2025 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #04116 | DOB VIOLATION - ACTIVE |
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 2:55 AM ET. BBL 4123930001.