7 floors · 33,101 sq ft · built 2017 · class H9 · owner of record: Southern Blvd Hotel Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | Feb 21, 2027 in 120 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 33,101 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 189 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 189 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 799 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 19, 2024 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS#35549134L ISSUED ON 3/5/2021,AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1RCNY 102-01(D)(2).AN ACCEPTABLE CERTIFICAT #37027092R | Mar 5, 2027 | $3,125 |
| Feb 21, 2024 | Construction CLASS - 1 UPON REVIEWING DOB'S INTERNAL SYSTEMS, BIS AND DOB NOW, NOTICED CONSTRUCTION SUPERINTENDENT, JOHN P. SADOWSKI, WITH LICENSE NUMBER 026868 FOR THE JOB AT 1122 SOUTHERN BLVD, PERMIT # 220539594, HAS AN EXPIRED LI #39525801P | Apr 8, 2027 | $6,250 |
| Apr 19, 2021 | Construction CLASS - 1 BC 1704.1.3 BASED ON CONCRETE ENFORCEMENT UNIT(CEU) AUDIT AND FINDINGSTR2 COMPRESSION TEST REPORT INDICATE CONCRETE EXAMPLES TAKEN ON 9/20/17,9/25/17,10/6/17.HOWEVER TR1 SPECIAL INSPECTION FOR CONCRETE-COST IN #35537624X | Jul 2, 2021 IN VIOLATION | $2,500 |
| Mar 5, 2021 | Construction CLASS - 2 28-105.12 CONDATION OF NEW BUILDING PERMIT.AS NOTED:AT TIME OF INSPECTION FOR AN ACTIVE CONSTRUCTION SITE AT BULKHEAD LEVEL.OBSERVED THE BUILDING CONSTRUCTED UP TO BULKHEAD LEVEL AS STEEL STRUCTURE NOT CONFORM #35549134L | May 21, 2021 STIPULATION/IN-VIO | $630 |
| Mar 5, 2021 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DRAWING.AS NOTED:AT TIME OF INSPECTION FOR AN ACTIVE CONSTRUCTION SITE AT BULKHEAD LEVEL.OBSERVED AT CELLAR LEVEL AND SUBCELLAR LEVEL FOUNDATION WORK CONSTRUCTED.N #35549133J | Nov 5, 2021 IN VIOLATION | $2,500 |
| Mar 5, 2021 | Construction CLASS - 1 BC 3301.7 FAILURE TO PROVIDE APPROVED P.E. CONSTRUCTION DOCUMENTS.AS NOTED:AT TIME OF INSPECTION AT A 7 STORY BUILDING JOBSITE OBSERVED STEEL STAIRCASE ERECTED FROM CELLAR LEVEL TO ROOF LEVEL AND FROM ROOF TO E #35549449X | Nov 5, 2021 IN VIOLATION | $2,500 |
| Mar 17, 2020 | Construction CLASS - 2 BC33141-SUPPORTED SCAFFOLD DOES NOT MEET COE SPECIFICATION.AT THE TIMEOF INSPECITON I OBSERVED SWS AND SUPPORTED SCAFFOLD IN PLAE.SUPPORTED SCAFFOLD NOT COMPLY WITH CODE SPECIFICATION:MISISNG MIDRAILS IN MULTIP #35469165Y | Dec 10, 2021 DEFAULT | $3,125 |
| Mar 17, 2020 | Construction CLASS - 1 BC33016-TEMPORARY CONSTRUCTION EQUIPMENT.NOTE:AT THE TME OF MY INSPECTION ON AN ACTIVE JOBSITE OF A 7 STORY BUILDING AT ROOF LEVEL I OBSERVED MAKESHIFT RIGGING EQUIPMENT COMPRISED OF 3 FRAME HIGH ERECTED SUPPOR #35469168J | Dec 10, 2021 DEFAULT | $6,250 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 8:26 PM ET. BBL 2027450002.