4 floors · 114,700 sq ft · built 1907 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-27 (Accepted). Agency page | Dec 31, 2026 in 43 days | 1 of 3 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 114,700 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 408 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6535). Agency page | Dec 31, 2035 in 3330 days | Next due 2035 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 4, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR SUMMONS 39138147J., FILE A CERTIFICATE OF CORRECTION #39191325X | Aug 19, 2026 IN VIOLATION | $1,250 |
| Jun 4, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR SUMMONS 39138145X., FILE A CERTIFICATE OF CORRECTION #39191324Y | Aug 19, 2026 IN VIOLATION | $1,250 |
| Feb 26, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, THE TIME OF INSPECTION, THE FOLLOWING ROOM DOORS WERE NOT SELF-CLOSING:-305, 205, 212, 213, 215, 216, 223, 120, 121. CORRIDOR DO #35722275L | Apr 10, 2026 POP/IN-VIO | $0 |
| Feb 26, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC 6 EMERGENCY LIGHTS IN GYM WERE NOTWORKING(BACK GYM). 1 EMERGENCY LIGHT IN FRONT GYM WERE NOT WORKING. AL #35722277P | Apr 10, 2026 POP/IN-VIO | $0 |
| Feb 26, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8; 27-371(J). AT THE TIME OF INSPECTION, THE FOLLOWING ROOM DOORS HAD TURN KNOB HANDLES:-321, 315, 305 #35722276N | Apr 10, 2026 POP/IN-VIO | $0 |
| Feb 11, 2025 | Unknown CLASS - 1 AT THE TIME OF INSPECTION, THE CONTRACTOR FAILED TO COMPLY WITH THE LOAD CAPACITY FOR THE SCAFFOLDING. ACCORDING TO CHAPTER 33, SECTION 3314.4.4.2, "LOADS SHALL NOT BE CONCENTRATED IN A MANNER THAT CAUSES STRES #39138147J | Oct 6, 2025 IN VIOLATION | $0 |
| Feb 11, 2025 | Construction CLASS - 1 - AT THE TIME OF INSPECTION, THE CONTRACTOR FAILED TO PROVIDE ADEQUATE GUARDRAIL SYSTEMS. I OBSERVED MISSING GUARDRAILS AT VARIOUS LOCATIONS. ADDITIONALLY, THE GUARDRAILS THAT ARE IN PLACE CONSIST OF CROSS-BRAC #39138145X | Oct 6, 2025 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #18909 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #18910 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #18911 | DOB VIOLATION - ACTIVE |
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 18, 2026, 9:17 AM ET. BBL 3065350011.