Brooklyn · Block 169 · Lot 9 · 11201

112 Schermerhorn Street

3.5 floors · 28,301 sq ft · built 1857 · class W2 · owner of record: New York Quarterly M

21open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
165dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 28,301 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 165 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 165 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1140 days
Next cycle year 2029
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-26 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7)
IssuedViolationHearingBalance
Feb 3, 2026Construction CLASS - 2
REISSUE: 35691811R-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: CUSTODIAN OFFICE IS IN THE ELECTRICAL/GAS METER RM. ALSO NOTED: BUCKETS, CLEANING MATERIALS, BOXES OFC. REMEDY: COMPLY WITH CODE.
#35725022R
Feb 18, 2026
POP/IN-VIO
$0
Feb 25, 2025Construction CLASS - 2
REISSUE: 35678628M-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: CELLAR LEVEL ELECTRICAL RM AND GAS METER RMS ARE BEING USED AS CUSTODIAN OFFICE. REMEDY: COMOLY WITH CODE.
#35691811R
May 1, 2025
POP/IN-VIO
$0
Jan 30, 2024Construction CLASS - 2
REISSUE: 35671600Z-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: AT CELLAR LEVEL ELECTRICAL RM. ALSO USED FOR CUSTODIAN OFFICE HAS STORAGE. REMEDY: COMPLY WITH CODE.
#35678627K
Apr 22, 2024
POP/IN-VIO
$0
Apr 11, 2019Construction CLASS - 2
OPERATION OF PLACE OF ASSEMBLY W/O A CURRENT CERTIFICATE OF OPERATION.@ TIME OF INSP. OBSERVED @ 2ND FL A SANCTUARY WITH CAPACITY TO SIT APPROX. 200 PEOPLE APPROX. 55'X47'. ALSO OBSERVED @ 1ST FL A READING FACI
#35416355X
Jul 22, 2019
IN VIOLATION
$0
Oct 26, 2016Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES & PUBLIC CORRIDORS PER BC1006.1;27-542. NOTED: EMERGENCY LIGHTS NOT WORKING WHEN TEST BY THE FRONT DOORS &
#35216925M
Dec 12, 2016
DEFAULT
$0
May 17, 2013Construction CLASS - 2
FAILURE TO MAINTAIN: NOTED INTERIOR HORIZONTAL CRACKS IN BULKHEAD WALLS WHERE WALL MEETS ROOF. RMDY: OBTAIN ALL NECESSARY PERMITS - REPAIR DEFECTS.
#35019299L
Jul 1, 2013
ADMIT/IN-VIO
$0
Aug 3, 2006Construction Non-Hazardous
FAILURE TO PROVIDE PROTECTION AT SIDE OF EXCAVATION. UPON INSP OF ABOVE PROPERTY: APPROX 8'-9' DEEP X 15' LONG TRENCH HAS BEEN EXCAVATED ANDTHERE IS NO SHEETING SHORING OR BRACING.THERE ALSO IS A APPROX 5' HIGH
#34531090R
Sep 25, 2006
IN VIOLATION
$0
DOB (9)
IssuedViolationStatus
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#19231
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#16896
DOB VIOLATION - ACTIVE
Feb 13, 2004LOCAL LAW 62/91 - BOILERS

#16889
DOB VIOLATION - ACTIVE
Feb 7, 2000LOCAL LAW 62/91 - BOILERS

#12907
DOB VIOLATION - ACTIVE
Feb 7, 2000LOCAL LAW 62/91 - BOILERS

#12909
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#28016
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#28414
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#28413
DOB VIOLATION - ACTIVE
Jun 12, 1990CONSTRUCTION

#02F2
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Feb 13, 2004Boiler LL6291
Active
Feb 7, 2000Boiler LL6291
Active
Feb 7, 2000Boiler LL6291
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 5:55 PM ET. BBL 3001690009.