Staten Island · Block 7206 · Lot 171 · 10309

112 Industrial Loop

1 floors · 29,566 sq ft · built 1991 · class E1 · owner of record: Sml Realty, Llc

9open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
191dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 70 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 29,566 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 191 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 191 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 801 days
Next cycle year 2028

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Jul 25, 2006Construction Non-Hazardous
WORK W/O A PERMIT NOTED:@ TIME OF INSP OF CONST UNDER NEW BLDG APPL# 1227/87 A 2ND FLR WAS CREATED WHEN THE ORGINAL APPLICATION WAS FOR A ONE STORY BLDG & THE FINAL COFO# 5P0005014 ALSO REFLECT THIS BLDG AS A 1
#34523774H
Nov 8, 2006
IN VIOLATION
$0
DOB (7)
IssuedViolationStatus
Feb 3, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00109
DOB VIOLATION - ACTIVE
Oct 26, 2020CONSTRUCTION
FTM:2FL LVL &SPRNKLR LVL ADDED W/O PRMTS.STL BEAMS UNBRCD THR-OUT 2FLR LVL.CONNCT&STL FRMG@2FL APPEARS UNENGR'D.PLYWD FLRING NOT ADEQ SUPPRTD GAPS &OPNGS 2FL.WD FRME STAIR ADED TO ACCESS 2FL NOT CODE COMPLIANT.PE ENG'R IMMD EVAL ENTRE BLDG.OBTN PRMTS LEGALIZE 2FL&REMAIND WRK ACHIEVE CODE COMPLINC.FI
#FEU50301BS
DOB VIOLATION - ACTIVE
Sep 25, 2020CONSTRUCTION
AT TIME OF INSPECTION OBSERVED BUILT 2ND FLOOR LEVEL ILLEGALLY WITH I-BEAMS & PLYWOOD FLOORING CREATED FURNITURE AND COMBUSTIBLE MATERIALS STORAGE SPACE. LAID DOWN PLYWOOD OVER METAL BEAMS INADEQUATE MANNER WITHOUT FIRE STOPPING MATERIALS. GAPS, LOOSE AND BUMP OBSERVED ON PLYWOOD FLOORING.
#20-01318
DOB VIOLATION - ACTIVE
Dec 18, 2006CONSTRUCTION

#031FC
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Dec 18, 2006PLUMBING

#03FL01
VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE
Dec 18, 2006CONSTRUCTION

#032FC
DOB VIOLATION - ACTIVE
Dec 18, 2006CONSTRUCTION

#033FC
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Feb 3, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 22, 2026, 9:52 PM ET. BBL 5072060171.