12 floors · 126 apartments · 350,186 sq ft · built 2019 · class D7 · owner of record: Eastern Emerald Group Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 50 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 66 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 350,186 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 171 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 171 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Energy audit and retro-commissioning (2027) Likely applies Local Law 87 · Calendar year 2027 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1707). Agency page | Dec 31, 2027 in 415 days | Next due 2027 |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page | Feb 21, 2028 in 467 days | No Cycle 10 report on record yet |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 781 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 4, 2026 | Construction CLASS - 1 OBSERVED CLOSED JOBSITE IN FOUNDATION PHASE FOR PROPOSED 25-STORY BUILDING. UPON INSPECTION, SIDEWALK IS NOT CLEARED OF SNOW AND ICE AT NORTHERN BOULEVARD ÝEXPOSURE #1¨ AND 114TH STREET ÝEXPOSURE #4¨. SIDEWALK #39549929K | Apr 14, 2026 DEFAULT | $12,500 |
| Feb 4, 2026 | Unknown CLASS - 2 OBSERVED CLOSED JOBSITE IN FOUNDATION PHASE FOR PROPOSED 25-STORY BUILDING. UPON INSPECTION, NO WATCHPERSON WAS PRESENT ON THE JOBSITE. CALLED OUT LOUDLY SAYING "WATCHPERSON" AND BANGED ON CONSTRUCTION FENCE DO #39549928Z | Apr 14, 2026 DEFAULT | $10,000 |
| Dec 28, 2023 | Construction CLASS - 2 OBSERVED NON ACTIVE SITE FOUNDATION PHASE HUGE PUDDLE WATER STANDING NO ACTIVE DRAINAGE SYSTEM WAS OBSERVED THROUGHOUT JOB SITE AFTER SEARCHING PERIMETERS OF EXP1,2,3,4 CREATES HAZARDS EROSION SOIL BERM THUS RE #39524398J | Sep 24, 2024 DEFAULT | $6,250 |
| Dec 28, 2023 | Construction CLASS - 2 OBSERVED CONSTRUCTION FENCE ENCLOSING PUBLIC SIDEWALK EXP2 AND PORTION OF PUBLIC SIDEWALK EXP3 AND 4, REVIEWED DOT WEBSITE REVEALED NO ACTIVE PERMITS FOR STREETS 112TH PLACE AND 114 STREET NOT IN COMPLIANCE WIT #39524397H | Sep 24, 2024 DEFAULT | $10,000 |
| Dec 28, 2023 | Construction CLASS - 1 OBSERVED NONACTIVE SITE FENCESECURED CHAINED PADLOCKED EXP1,2,3,4,SPOKE WITH WORKER EXP3 STATED NOT WATCHPERSON AND PERFORMING MAINTENANCE EXCAVATOR,REVIEWED PERMIT APP.421003103 REVEAL BUILD.FOOTPRINT OVER40,0 #39524396X | Sep 24, 2024 DEFAULT | $25,000 |
| May 23, 2023 | Construction CLASS - 2 AT TIME OF INSPECTION OF INACTIVE JOBSITE OBSERVED ERECTED TEMPORARY CONSTRUCTION FENCE AT EXP#1,2,3,4, UPON REVIEWING DEPARTMENT RECORDS NO ACTIVE PERMIT FOR ERECTED TEMPORARY CONSTRUCTION FENCE. #39516964P | Aug 1, 2023 DEFAULT | $3,125 |
| Mar 8, 2023 | Construction CLASS - 1 AT TIME OF INSPECTION, I OBSERVED CONSTRUCTION FENCE IN PLACE WITH EXPIRED PERMIT. AT EXPOSURE 2 AND 4 THE CONSTRUCTION FENCE IS OBSTRUCTING THE PEDESTRIAN WALKWAY CREATING AN HAZARDOUS CONDITION FOR PEDESTRIAN #39513889K | May 16, 2023 DEFAULT | $25,000 |
| Mar 8, 2023 | Construction CLASS - 1 AT TIME OF INSPECTION, SITE IS CLOSED AND INACTIVE. UPON SHOUTING AND KNOCKING ON THE FENCE TO ALERT WATCHPERSON AND VERIFY COMPLIANCE WITH BC 3303.3; NO WATCHPERSON WAS ON SITE. THESE CONDITIONS POSES A SEVERE #39513888Z | May 16, 2023 DEFAULT | $12,500 |
| Jan 31, 2023 | Construction CLASS - 2 AT THE TIME OF INSPECTION 12 STORIES NB IN SOE PHASE I OBSERVED PLASTIC BARRIERS PLACED ON STREET HAVING CONSTRUCTION PLYWOOD FENCE INSTALLED ABOVE THE BARRIERS ON 112 STREET BETWEEN NORTHERN BLVD AND ASTORIA #39512379X | Sep 26, 2023 DEFAULT | $6,250 |
| Jan 15, 2023 | Construction CLASS - 2 APPROXIMATELY 80' OF CONSTRUCTION FENCE IS MISSING AT NORTHERN BLVD AND 114 ST. LEAVING SITE OPEN WITH 40FT+ DROP. TEMP NETTING IN PLACE AT THIS TIME., RENEW PERMIT; REPAIR FENCE #39077778J | Oct 24, 2023 DEFAULT | $3,125 |
| Jan 15, 2023 | Construction CLASS - 2 APPROXIMATELY 80' OF CONSTRUCTION FENCE IS MISSING AT NORTHERN BLVD AND 114 ST. LEAVING SITE OPEN WITH 40FT+ DROP. TEMP NETTING IN PLACE AT THIS TIME., COMPLY WITH CODE; REPAIR FENCE AND MAINTAIN AS PER CODE #39077777H | Oct 24, 2023 DEFAULT | $10,000 |
| Dec 16, 2022 | Construction CLASS - 1 AT THE TIME OF INSPECTION I OBSERVED NO PEDESTRIAN WALKWAY IS PROVIDED AT EXPOSURE 2 (112TH PLACE) AND EXPOSURE 4 (114TH STREET) WHERE THE CONSTRUCTION FENCE OBSTRUCTS THE SIDEWALK COMPLETELY. THIS CREATES HAZA #39510457N | Dec 5, 2023 DEFAULT | $25,000 |
| Dec 16, 2022 | Construction CLASS - 1 AT THE TIME OF INSPECTION I OBSERVED NO WATCHPERSON ON SITE AS REQUIRED BY SECTION 3303.3 OF BUILDING CODE.PROVIDE AND MAINTAIN WATCHPERSON AS PER CODE. #39510456L | Dec 5, 2023 DEFAULT | $12,500 |
| Dec 16, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION I OBSERVED CONSTRUCTION FENCE NOT MAINTAINED AS PER CODE. SECTIONS OF FENCE ARE LOOSE AND IN DANGER OF DISLODGEMENT CREATING HAZARDS FOR THE PUBLIC AND PEDESTRIANS. FENCE AT EXPOSURE 1 #39510455J | Dec 5, 2023 DEFAULT | $5,000 |
| Aug 2, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION JOBSITE WAS CLOSED. AS PER PERIMETER INSPECTION I OBSERVED, PUBLIC SIDEWALK WAS OCCUPIED WITH CONSTRUCTION FENCE AT EXPOSURE # 4 &1. ADDITIONALLY, SCATTERED YODOKS ON STREET WITHOUT HA #39504444N | Oct 3, 2023 DEFAULT | $6,250 |
| Aug 2, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION JOBSITE WAS CLOSED/ PADLOCKED. AS PER PERIMETER INSPECTION I OBSERVED, THERE WAS NO ACTIVE FENCE PERMIT POSTED ON SITE. BESIDES THAT AS PER RESEARCH ON BIS AND DOB NOW, UNABLE TO FOUND #39504443L | Oct 3, 2023 DEFAULT | $3,125 |
| Aug 2, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION, CONSTRUCTION SITE WAS CLOSED. AS PER PERIMETER INSPECTION I OBSERVED, JOBSITE FENCE PANEL WAS FALLING APART AT EXPOSURE # 2. FENCE WAS NOT FULLY ENCLOSED AND NOT VERTICALLY PLUMB. BES #39504442J | Oct 3, 2023 DEFAULT | $5,000 |
| Aug 2, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION I OBSERVED, PUBLIC WALKWAY WAS UNDERMINE BY THE JOBSITE ACTIVITY. THERE WAS NO CLEAR 5 FT WALKWAY FOR PUBLIC AT EXPOSURE# 3 & 4. ADDITIONALLY, PUBLIC SIDEWALK WAS OBSTRUCTED WITH BROKE #39504445P | Oct 3, 2023 DEFAULT | $10,000 |
| Aug 2, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION I OBSERVED, CONSTRUCTION SITE WAS CLOSED/ PADLOCKED. THERE WAS NO COMPETENT WATCH PERSON ON SITE DURING WHEN THE OPERATION WAS NOT IN PROGRESS. WATCHPERSON IS REQUIRED AN INDIVIDUAL B #39504446R | Oct 3, 2023 DEFAULT | $6,250 |
| May 9, 2022 | Construction CLASS - 2 EXPIRED FENCE PERMIT.ATOI OF PROPOSED NB JOBSITE UNDER EARTHWORK/FOUNDATION.UPON REV OF DEPT RECORD I OBSERVED FRIGING TEMP CONST EQUIPMENT (FENCE) IN PLACE W/PERMIT421003103 EXPIRED5/1/19&NOT REMOVED.COMPLY W/ #35649919J | Jun 25, 2024 DEFAULT | $3,125 |
| May 9, 2022 | Construction CLASS - 2 BC3307.4.3 YODOCKS/BARRIERS NOT FILLED/VEHICULAR TRAFFIC.ATOI OF PROPOSED NB JOBSITE UNDER EARTHWORK/FOUNDATION.I OBSERVED@EXP2&3 ON STREET W/YODOCKS NOT FILLED NOT PROPERLY INSTALLED/CONNECTED,NO DIRECTIONAL E #35649920R | Jun 25, 2024 DEFAULT | $10,000 |
| Nov 8, 2021 | Construction CLASS - 1 3303.3 FAILURE TO PROVIDE COMPETENT WATCH PERSON AS REQUIRED.AT THE TIME OF INSPECTION,CONSTRUCTION SITE WAS CLOSED AND INACTIVE.AS PER PERIMETER INSPECTION,I OBSERVED THERE WAS NO WATCH PERSON ON SIYTE.THE BUI #35583073X | Mar 8, 2022 DEFAULT | $6,250 |
| Nov 8, 2021 | Construction CLASS - 1 3307.2.2 TEMPORARY PUBLIC WALKWAY IN THE STREET.AT THE TIME OF INSPECTION,CONSTRUCTION SITE WAS CLOSED.AS PER PERIMETER INSPECTION,I OBSERVED PEDESTRIAN WALKWAY WAS NOT PROTECTED ALL AROUND THE CONSTRUCTION SIT #35583074H | Sep 27, 2022 DEFAULT | $6,250 |
| May 1, 2021 | Construction CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ONSITE-EXPIRED PERMIT.JOBSITE FENCE PERMIT HAS EXPIRED AND NO CURRENT PERMIT ON FILE.REMEDY:OBTAIN PERMIT. #35507529K | Oct 5, 2021 DEFAULT | $3,125 |
| May 1, 2021 | Construction CLASS - 2 JOB SITE NOT CONSTRUCTED PURSUANT TO SUBSECTION(DEFECTIVE FENCE)AT EXPOSURES 1 AND 2 FENCE BULGING WITH ROTTED AND HANGING WOOD PANELS AT VARIOUS LOCATIONS.REMEDY:REPAIR OR REPLACE FENCE. #35507528Z | Oct 5, 2021 DEFAULT | $2,500 |
| Sep 28, 2020 | Construction CLASS - 2 FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35444528N ISSUED ON 8/5/2019,& TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 & 1RCNY 102-01(D)(2).AN ACCEPTIBLE CERTIFICATE HA #37020167K | Mar 16, 2021 IN VIOLATION | $1,250 |
| Apr 28, 2020 | Construction CLASS - 1 BC3304.4 AND BC 1604.2 DEFICIENT DESIGN-THE RESPONDENT DESIGN APPLICANT(JOB#421479812)SUBMITTED SUPPORT OF EXCAVATION DRAWINGS WHICH FAIED TO IDENTIFY ALL ADJOINING UTILITIES AND TAKE THEM INTO ACCOUNT ADDITION #35472593H | Apr 26, 2022 DEFAULT | $25,000 |
| Apr 28, 2020 | Construction CLASS - 1 BC3309.6 THE RESPONDENT,DESIGN APPLICANT JOB#421479812,FAILED TO HAVE A SUFFICIENT MONITORING PROTOCOL FOR SUBSURFACE OPERATIONS IMPOSING LOAD ON ADJOINING PROPERTY(PUBLIC INFRASTRUCTURE).MONITORING READINGS WE #35472594J | Apr 26, 2022 DEFAULT | $25,000 |
| Apr 28, 2020 | Construction CLASS - 1 BC3309.6 THE RESPONDENT,DESIGN APPLICANT JOB#421010060,FAILED TO HAVE A SUFFICIENT MONITORING PROTOCOL FOR SUBSURFACE OPERATIONS IMPOSING LOADS ON ADJOINING PROPERTY(PUBLIC INFRASTRUCTURE).MONITORING READINGS W #35472591Y | Apr 26, 2022 DEFAULT | $25,000 |
| Apr 28, 2020 | Construction CLASS - 1 BC3304.4 AND BC1604.2 DEFICIENT THE RESPONDENT DESIGN APPLICANT JOB#421010060 SUBMITTED SUPPORT OF EXCAVATION DRAWINGS WHICH FAILED TO IDENTIFY ALL ADJOINING UTILITIES & TAKE THEM INTO ALLOWING ADDITIONALLY THE #35472590M | Apr 26, 2022 DEFAULT | $25,000 |
| Apr 28, 2020 | Construction CLASS - 1 MATERIAL FALSE STATEMENT THE RESPONDENT DESIGN APPLICANT JOB#421010060MADE A MATERIAL FALSE STATEMENT TO THE DEPARTMENT WHEN THEY SIGNED BOX5 OF THE TRI FORM CERTIFYING THAT SPECIAL INSPECTION AGENCY,SO ARCH & #35472592X | Apr 26, 2022 DEFAULT | $25,000 |
| Apr 28, 2020 | Construction CLASS - 1 A MATERIAL FALSE STATEMENT WAS SUBMITTED TO THE DEPARTMENT BY THE RESPONDENT THE SPECIAL INSPECTION AGENCY JOB#421479812.THE SPECTIAL INSPECTION AGENCY WAS REGISTERED AS A CLASS 2 INSPECTION AGENCY AND WAS NOT #35472597P | Jan 19, 2021 ADMIT/IN-VIO | $0 |
| Apr 28, 2020 | Construction CLASS - 1 A MATERIAL FALSE STATEMENT WAS SUBMITTED TO THE DEPARTMENT BY THE RESPONDENT THE SPECIAL INSPECTION AGENCY JOB#421010060.THE SPECIAL INSPECTION AGENCY WAS REGISTERED AS A CLASS 2 INSPECTION AGENCY AND WAS QUALI #35472596N | Apr 26, 2022 DEFAULT | $25,000 |
| Apr 28, 2020 | Construction CLASS - 1 MATERIAL FALSE STATEMENT-THE REPONDENT DESIGN APPLICANT JOB#421479812 MADE A MATERIAL FALSE STATEMENT TO THE DEPARTMENT WHEN THEY SIGNED BOX5 OF THE TRI FORM CERTIFYING THAT THE SPECIAL INSPECTION AGENCY,50 ADC #35472595L | Apr 26, 2022 DEFAULT | $25,000 |
| Aug 12, 2019 | Construction CLASS - 1 FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.AS NOTED IN THE REMEDY OF DOB CONTROL #316059,VIOLATION#030719CE40302MM,THE RESPONDENT WAS REQUIRED TO SUBMIT SHOP DRAWINGSAND INSPECTION REPORTS FOR THE SOIL #35343572H | Oct 12, 2021 DEFAULT | $6,250 |
| Aug 5, 2019 | Construction CLASS - 2 FENCE PERMIT EXPISRED AT THE TIME OF MY INSPECTION I REVIEWED THE BIS SYTEM AND FOUND THE FENCE PERMIT TO HAD EXPIRED ON 5-21-2019 THERE WERE NO EVIDENCE OF RENEWAL FOR THE FENCE ENCLOSING THE SITE COMPLY WITH #35444528N | Oct 22, 2019 STIPULATION/IN-VIO | $630 |
| Aug 5, 2019 | Construction CLASS - 2 PEDESTRIAN PROTECTION INADEQUATE. AT TIME OF M INPSECTION, OBSERVED THAT ON THE YODUCK SYSTEM PROVIDE ON 112 ST AND 114 ST ARE INADEQUATE MANY ODUCKS ARE BROKEN AND IN BAD SHAPE. ALL YODUCK ARE MISSING WATER #35444397M | Nov 26, 2019 IN VIOLATION | $2,400 |
| Mar 20, 2019 | Construction CLASS - 1 3301.3 FAILURE TO DESIGNATE CONCRETE SAFETY MANAGER. AT TIME OF INSPECTION I OBSERVED THE CONCRETE SAFETY MANAGER DESIGNATED , THOMAS HANDYHAS NOT BEEN ON SITE FOR LONGER THAN ALLOWED PER CODE. LAST LOGBOOK #35363967K | Oct 22, 2019 IN VIOLATION | $625 |
| Mar 20, 2019 | Construction CLASS - 1 3301.3 FAILURE TO DESIGNATE SITE SAFETY MANAGER. AT THE TIME OF INSPECTION OBSERVED THE SITE SAFETY MANAGER DESIGNATED KHOSRON G YARAHMADIHAS OT BEEN ON SITE SINCE 12/20/18 ACCORDING TO LAST LOGBOOK ENTRY ON #35363966Z | Oct 22, 2019 IN VIOLATION | $625 |
| Mar 14, 2019 | Construction CLASS - 1 FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER UPON INSPECTION I OBSERVED FAILURE TO COMPLY WITH DOB VIOLATION 316051 ISSUED ON 01/16/19 WITH AN ORDER TO PULL A PERMIT WITHIN 7 BUSINESS DAYS.AS OF 03/14/19 #35363963N | Feb 18, 2020 DEFAULT | $3,668 |
| Mar 13, 2019 | Construction CLASS - 1 BC3301.3/NO CONCERTE SAFETY MANAGER DESIGNATED AT TIME OF INSPECTION IOBSERVED A CONCRETE SAFETY MANAGER,MARK T.O'CCONOR WHO IS NOT DESIGNATED ON THE PW2 DESIGNATED CONCRETE SAFETY MANAGER,THOMAS HENDY ON PW2 H #35363962L | Feb 25, 2020 DEFAULT | $6,250 |
| Mar 13, 2019 | Construction CLASS - 1 BC3301.3/NO SITE SAFETY MANAGER DESIGNATED.AT THE TIME OF INSPECTION I OBSERVED A SITE SAFETY MANAGER JAVID M. CHAUNDRY WHO IS NOT DESIGNATED DESIGNATED SITE SAFETY MANAGER DESIGNATED ON PW2,KHOSROW G.PARAHMADI #35363961J | Feb 25, 2020 DEFAULT | $6,250 |
| Feb 16, 2019 | Construction CLASS - 1 3304.7 ACCESS/EGRESS AT THE TIME OF MY INSPECTION I OBSERVED 3 WORKERSPERFORMING REBAR OPERATION APPROXIMATELY 15 FEET ABOVE GROUND. I ALSO OBSERVED EGRESS FOR 3 WORKERS TO GET OUT SAFELY. REMEDY: STOP ALL #35377169N | Oct 1, 2019 IN VIOLATION | $2,500 |
| Feb 16, 2019 | Construction CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDERL.AT THETIME OF MY INSPECTION I OBSERVD THAT WORK ON REBAR HAS BEEN PERFORMED WHILE ON NOTICE OF A STOP WORK ORDER ISSUED ON THE 02/16/19 VIOLATING #35377171M | Jun 18, 2019 IN VIOLATION | $5,000 |
| Feb 16, 2019 | Construction CLASS - 1 GUARDRAILS SYSTEM.AT THE TIME OF MY INSPECTION I OBSERVED WORKING PER FORMING REBAR OPERATIONS AT OPEN EDGE OF EXCAVATION OF APPROXIMATELY 15FT IN DEPTH I ALSO OBSERVED THAT THERE WERE NO GUARDRAILS IN PLACE TO #35377173X | Jun 11, 2019 IN VIOLATION | $2,500 |
| Feb 16, 2019 | Construction CLASS - 2 FAIL TO INSTITUTE AND MAINAIN SAFE OPERATIONS.AT THE TIME OF MY INSPECTION I OBSERVED I OBSERVED 3 WORKERS PERFORMING REBAR OPERATION AT THEEDGE OF UNPROTECTED EXCAVATION OF A HEIGHT OF APPROXIMATELY 15FT PUTTI #35377172Y | Jun 11, 2019 IN VIOLATION | $625 |
| Jan 4, 2019 | Unknown CLASS - 1 PERMIT HOLDER FAILED TO ENSURE WORKERS ATTENDED PRE-SHIFT SAFETY MEETING PRIOR TO COMMENCEMENT OF WORK.UPON A REQUEST FOR A PRETRACK/PRESHIFT MEETING FOR OPERATIONS AT THE SITE,NONE WERRE GIVEN AND NONE WERE AV #35376985R | Nov 14, 2023 DEFAULT | $25,000 |
| Jan 4, 2019 | Construction CLASS - 1 FAILURE TO IMMEDIATELY NOTIFY THE DEPT OF ACCIDENT MATERIAL FAILURE AND PARITAL COLLAPSE F THE SUPPORT OF EXCAVATION WALL ALONG NORTHERN BLVD THAT TOOK PLACE ON 1/4/19 NYPD NOTIFIED THE DEPARTMENT OF THE ACCIDE #35376987K | Nov 14, 2023 DEFAULT | $25,000 |
| Jan 4, 2019 | Construction CLASS - 1 THE PERMIT HOLDER UNLAWFULLY CONTINUED TO WORK WHILE ON NOTICE OF A STOP WORK ORDER-ON THE DATE OF OCCURRENCE AND ACCIDENT TOOK PLACE.WORKERS WERE ENGAGING IN CONSTRUCTION ACIVITIES ON SITE WHEN THE SUPPORT OF #35376999H | Nov 14, 2023 DEFAULT | $25,000 |
| Jan 4, 2019 | Construction CLASS - 1 NO CONCRETE SAFETY MANAGER.THE RESPONDENT PERMIT HOLDER DID NOT HAVE THE (CSM)PRESENT ON SITE DURING CONSTRUCTION ACTIVITIES.WORK WAS TAKINGPLACE CONTRARY TO SWO ISSUED 12/20/18 THROUGH COMPLIANT #4758083 AND A #35376989Y | Nov 14, 2023 DEFAULT | $25,000 |
| Jan 4, 2019 | Construction CLASS - 1 THE RESPONDENT FAILRED TO SAFEGUARD THE PUBLIC AND PROPERTY OBSERVED AT EXPOSURE 1,SIDEWALK AND PART OF THE STREET AT NORTHERN BLVD HAD COLLAPSED INTO THE SITE THEIS FAILURE RESULTED IN THE MANDATED CLOSURE OF #35376998X | Nov 14, 2023 DEFAULT | $25,000 |
| Jan 4, 2019 | Unknown CLASS - 1 FAILURE TO MAINTAIN A RECORD OF ORIENTATIONS PERFORMED AT WORKSITE;UPON REQUEST FOR LOG OF SITE ORIENTATIONS PERFORMED ON SITE NONE WERE GIVEN,WORKERS ON SITE PERFORMING CONSTRUCTION ACTIVITIES WHILE ON NOTICE #35376990L | Nov 14, 2023 DEFAULT | $25,000 |
| Jan 4, 2019 | Construction CLASS - 1 NO SITE SAFETY COORDINATOR;PERMIT HODER FAILED TO HAVE A SITE SAFETY COORDINATOR PRESENT DURING CONSTRUCTION OPERATIONS,WORK WAS TAKING PLACCONTRARY TO SWO ISSUED ON 12/20/18 COMPLAINT#4758083 AND A INCIDENT TO #35376988M | Nov 14, 2023 DEFAULT | $25,000 |
| Dec 20, 2018 | Construction CLASS - 2 3301.7;FAILURE TO PROVIDE CONSTRUCTION DOCUMENTS AT TIME OF INSPECTION OBSEVRED AN ACTIVE CONSTRUCTION SITE IWTH TIE BACK AN CHORING SYSTEM WORK IN PROGRESS AT EPOSURE #1.DURING INSPECTION I REQUESTED FOR MONIT #35376743Y | Jun 4, 2019 IN VIOLATION | $1,250 |
| Nov 29, 2018 | Construction CLASS - 1 NO DESIGNATION OF SITE SAFETY MANAGER/COORDINATOR ON SITE. AT TIME OF INSPECTION OBSEVED ACTIVE JOBSITE. NO DESIGNATION OF SITE SAFETY MANAGER/COORDINATOR ON SITE. NO LOGBOOK ON SITE CREATED A HAZARDOUS CONDITI #35367551P | May 22, 2019 IN VIOLATION | $625 |
| Nov 29, 2018 | Construction CLASS - 2 WORK WITHOUT A PERMIT(EXPIRE PERMIT)AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE.SOME WORKERS WAS WORKING EXCAVATION ON FOUNDATION LEVEL.JOB NO :421003103 EXPIRES:10/10/2018(CREATED A DANGEROUS CONDITIONS FOR #35367571M | Jun 18, 2019 IN VIOLATION | $625 |
| Nov 9, 2018 | Construction CLASS - 1 FAILURE TO HAVE SITE SAFETY MANAGER OR COORDINATOR PRESENT AS REQUIRED. AT THE TIME OF MY INSPECTION OF AN 11 STORY BUILDING CURRENTLY AT FOUNDATION LEVEL WITH CONSTRUCTION OPERATIONS IN PROGRESS. UPON REQUEST #35367975Z | Nov 12, 2019 DEFAULT | $12,500 |
| Aug 20, 2018 | Construction CLASS - 1 FAILURE TO PROVIDE THE MINIMUM FREQUENCY SAMPLES FOR STRENGTH TEST OF CONCRETE SOE WALL APPROX 45FT HIGH AT EXP #1, #2 & #4. NO TECHNICAL REPORTS PROVIDED FOR CONCRETE PLACED AT SOE WALL. FAILURE TO PROVIDE TR- #35319350M | Jun 11, 2019 IN VIOLATION | $1,250 |
| Aug 1, 2018 | Construction CLASS - 2 FAILURE TO PROVIDE SPECIAL INSPECTION OF CONCRETE PLACEMENT. AS NOTED:AT TIME OF INSPECTION,ON AN ACTIVE CONSTRUCTION SITE,OBSERVED CONSTRUCTION AT SOE STAGE. WORKERS FINISHED PLACEMENT OF RE-BARS AT EXP#1 SOE #35273373Y | Feb 7, 2019 IN VIOLATION | $2,500 |
| Mar 9, 2018 | Site Safety CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER INVOLVING CONSTRUCTION. AT TIME OF INSPECTION IT WAS OBSERVED THAT THE CONTRACTOR FAILED TO COMPLY WITH COMMISSIONER'S ORDER TO BACK FILL EXP1 DOB VIO #35314133N | May 7, 2019 IN VIOLATION | $10,000 |
Showing 60 of 65. Full list on the agency site.
| Issued | Violation | Status |
|---|---|---|
| Jan 20, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00621 | DOB VIOLATION - ACTIVE |
| Jan 20, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00622 | DOB VIOLATION - ACTIVE |
| Jan 20, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00626 | DOB VIOLATION - ACTIVE |
| Jan 20, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00625 | DOB VIOLATION - ACTIVE |
| Jan 20, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00624 | DOB VIOLATION - ACTIVE |
| Jan 20, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00623 | DOB VIOLATION - ACTIVE |
| Jan 20, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00627 | DOB VIOLATION - ACTIVE |
| Jan 20, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00620 | DOB VIOLATION - ACTIVE |
| Nov 27, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00755 | DOB VIOLATION - ACTIVE |
| Nov 27, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00756 | DOB VIOLATION - ACTIVE |
| Nov 27, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00751 | DOB VIOLATION - ACTIVE |
| Nov 27, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00752 | DOB VIOLATION - ACTIVE |
| Nov 27, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00753 | DOB VIOLATION - ACTIVE |
| Nov 27, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00754 | DOB VIOLATION - ACTIVE |
| Nov 27, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00750 | DOB VIOLATION - ACTIVE |
| May 16, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #01326 | DOB VIOLATION - ACTIVE |
| Apr 2, 2019 | CONSTRUCTION #E40301MM | DOB VIOLATION - ACTIVE |
| Mar 7, 2019 | CONSTRUCTION #E40302MM | DOB VIOLATION - ACTIVE |
| Mar 7, 2019 | CONSTRUCTION #E40301MM | DOB VIOLATION - ACTIVE |
| Feb 19, 2019 | CONSTRUCTION #FEU40301TDL | DOB VIOLATION - ACTIVE |
| Feb 19, 2019 | CONSTRUCTION #FEU40302TDL | DOB VIOLATION - ACTIVE |
| Jan 16, 2019 | CONSTRUCTION #E40303MM | DOB VIOLATION - ACTIVE |
| Jan 4, 2019 | CONSTRUCTION ON 1/4/19 THE EXCAVATION WALL ALONG NORTHERN BLVD COLLAPSED INTO THE CONSTRUCTION SITE PORTION OF NORTHERN BLVD GAS PIPE ELECTRICAL FEEDERS FIBER OPTIC LINE&HYDRANT PIPE W/HYDRANT FELL INTO CONST SITE BY COB 2/28/19 PROVIDE DEPARTMENT WITH A REPORT OF INVESTIGATION-SOURCE OF COLLAPSE BY CONSULT EXPE #FEU40301TDL | DOB VIOLATION - ACTIVE |
| Jan 4, 2019 | CONSTRUCTION #E0301DH | DOB VIOLATION - ACTIVE |
| Dec 20, 2018 | CONSTRUCTION #E0301RV | DOB VIOLATION - ACTIVE |
| Jan 4, 2016 | CONSTRUCTION #C0305MG | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 3) | Active |
| Jan 20, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 20, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 20, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 20, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 20, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 20, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 20, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 20, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 27, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 27, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 27, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 27, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 27, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 27, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 27, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| May 16, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 1, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT | Active |
| Feb 7, 2000 | Boiler LL6291 | Active |
| Feb 7, 2000 | Boiler LL6291 | Active |
| Mar 16, 1999 | Boiler LL6291 | Active |
| May 4, 1998 | Boiler LL6291 | Active |
| May 4, 1998 | Boiler LL6291 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)