Queens · Block 11966 · Lot 6 · 11435

112-08 Sutphin Boulevard

2 floors · 2 apartments · 2,056 sq ft · built 1910 · class S2 · owner of record: Va Sutphin Blvd Llc

32open violations
$0ECB/OATH penalties owed
2HPD class C (immediately hazardous)
431dto Gas piping inspection (2027 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 310 days
Required only if the owner doesn't live there
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 431 days
Next cycle year 2027

Open violations

ECB / OATH (5)
IssuedViolationHearingBalance
Jan 5, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER FOR SUMMONS 39092478N. OBSERVED DAMAGED BRICK CHIMNEY OVER THE ADJACENT SCHOOL YARD. THE MASONRY FACADE AT EXP 1 AND 4 HAS SEVERE CRACKS FROM BASE TO ROOF,
#39172377Y
Mar 17, 2026
ADMIT/IN-VIO
$0
Jan 5, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER FOR SUMMONS 39097988X. OBSERVED THE MASONRY FACADE AT EXP 1 AND 4 HAS SEVERE CRACKS FROM BASE TO ROOF, DETERIORATING LINTELS, MISSING MORTAR, DAMAGED/BULGIN
#39172378X
Mar 17, 2026
ADMIT/IN-VIO
$0
Oct 25, 2023Construction CLASS - 1
NOTED.EXP4 MASONRY FACADE HAD A DIAGONAL STEP CRCKS NEAR 1/4CRNR EXTENDING FRM 2NDFL TO ROOF&BULGNG OUT SLIGHTLY.EXP1 2NDFL LINTELS CRCKD W/PARAPET LEANING.2NDFL WAS SLOPED TOWARDS EXP4.EXP4BRCK CHMNEY, REPAIR
#39097988X
Jan 2, 2024
DEFAULT
$0
Oct 25, 2023Construction CLASS - 1
FAILURE TO COMPLY WITH COMMISSIONER ORDER #4343176 (081523FEU41203FN) DATED AUGUST 15 2023 REQUIRING TO BE PERMANENTLY REPAIRED UNDER PERMIT STARTING BY SEPTEMBER 18 2023. AND COMPLETED AND SIGN OFF BY OCTOBER
#35412806H
Jan 19, 2024
DEFAULT
$0
Aug 14, 2023Construction CLASS - 1
EXP 4 OF BUILDING HAS LOOSE BRICKS IN THE CHIMNEY THAT ARE OVER THE SCHOOL YARD NEXT DOOR. ALSO LARGE CRACKS FROM BASE TO ROOF LEVEL, LARGE SECTION OF WALL 2FT IS UNSTABLE AND STARTED DISLODGING ITSELF FROM THE
#39092478N
Oct 24, 2023
DEFAULT
$0
DOB (4)
IssuedViolationStatus
Sep 22, 2023CONSTRUCTION
FTM.EXP4 MASONRY FACADE HAD A DIAGONAL STEP CRCKS NEAR 1/4CRNR EXTNDNG FRM 2NDFL TO ROOF&BULGNG OUT SLIGHTLY.EXP1 2NDFL LINTELSCRCKD WITH PARAPET LEANING.2NDFL WAS SLOPED TOWARDS EXP4.EXP4 BRCK CHMNEY IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER #343176(081523FEU41203PN) DATED AUGUST 15,2023
#FEU41201PN
DOB VIOLATION - ACTIVE
Aug 31, 2023UNSAFE BUILDINGS

#4090/23
DOB VIOLATION - ACTIVE
Aug 15, 2023CONSTRUCTION
FTM.EXP4 MASONRY FACADE HAD A DIAGONAL STEP CRCKS NEAR 1/4CRNR EXTENDING FRM 2NDFL TO ROOF&BULGNG OUT SLIGHTLY.EXP1 2NDFL LINTELS CRCKD W/PARAPET LEANING.2NDFL WAS SLOPED TOWARDS EXP4.EXP4BRCK CHMNEY OWNR TO RTAIN NYS PE TO EVAL ENT BLDG&FILE RPAIR DWGS..BLDG TO BE RPAIRD UNDR PRMT STRTNG BY9/18/23&
#FEU41203PN
DOB VIOLATION - ACTIVE
Aug 15, 2023IMMEDIATE EMERGENCY
REMEDY: INSTALL A TOTAL OF APPROXIMATELY 41 FEET OF SIDEWALK SHED. ALO LINEAR FEET. ALONG EXPOSURE 4 (NORTH SIDE) INSTALL APPROXIMATELY 20 LI
#17809
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (23) · C 2 · B 18 · A 3
IssuedClassViolationCorrect by
Oct 27, 2009CSECTION 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED SECURITY MATAL GATE AT PUBLIC HALL, 1st STORYNov 2, 2009
Oct 27, 2009ASECTION 27-2005 ADMIN. CODE: REFIT DOOR ENTRANCE AT PUBLIC HALL, 1st STORYJan 30, 2010
Oct 27, 2009BApt 2 · SECTION 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN SINK IN THE KITCHEN LOCATED AT APT 2, 2nd STORYDec 1, 2009
Oct 27, 2009BApt 2 · SECTION 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB IN THE BATHROOM LOCATED AT APT 2, 2nd STORYDec 1, 2009
Oct 27, 2009BApt 2 · SECTION 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASHBASIN IN THE BATHROOM LOCATED AT APT 2, 1st STORYDec 1, 2009
Oct 16, 2008BApt 2A · SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). WHICH IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, APARTMENT AT EASTNov 20, 2008
Oct 16, 2008BApt 2A · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, APARTMENT AT EASTNov 20, 2008
Oct 16, 2008BApt 2A · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, APARTMENT AT EASTNov 20, 2008
Oct 16, 2008BApt 2A · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW GLASS LOWER SASH FRONT SOUTH ROOM LOCATED AT APT 2A, 2nd STORY, APARTMENT AT EASTNov 20, 2008
Oct 16, 2008BApt 2A · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW LOWER SASH FRONT NORTH ROOM LOCATED AT APT 2A, 2nd STORY, APARTMENT AT EASTNov 20, 2008
Oct 16, 2008BApt 2A · SECTION 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES BATHTUB. IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, APARTMENT AT EASTNov 20, 2008
Oct 16, 2008BApt 2A · SECTION 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES BATHTUB. IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, APARTMENT AT EASTNov 20, 2008
Oct 16, 2008BApt 2A · SECTION 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, APARTMENT AT EASTNov 20, 2008
Oct 16, 2008ASECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING AIR VENT COVER ON SEWAGE PIPE BUILDING FRONT AT FRONT AREAWAYJan 19, 2009
Oct 16, 2008CSECTION 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER LOCK ON EXTERIOR METAL DOOR FRONT ENTRANCE TO BUILDING AT PUBLIC HALL, 1st STORYOct 22, 2008
Oct 16, 2008BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR FRONT ENTRANCE TO BUILDING AT PUBLIC HALL, 1st STORYNov 20, 2008
Oct 16, 2008BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE DOOR FRAME ENTRANCE TO BUILDING AT PUBLIC HALL, 1st STORYNov 20, 2008
Oct 16, 2008BApt 2A · SECTION 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN SINK IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, APARTMENT AT EASTNov 20, 2008
Aug 21, 2008ASECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE BRICKWORK AT 1ST STY. AT FRONT OF ENTRANCE DOOR AND TOP OF 2ND STY. WINDOW.Nov 24, 2008
Jun 6, 2007BApt 1F · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 2nd STORYJul 24, 2007
Jun 6, 2007BApt 1F · SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF WATER PENETRATE AT SOUTH WALL AT WINDOWS IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 1F, 2nd STORYJul 24, 2007
Jun 6, 2007BApt 1F · SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF WATER PENETRATE SOUTH WALL AT WINDOWS IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 1F, 2nd STORYJul 24, 2007
Jun 6, 2007BApt 1F · SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE FLEX LINE AT GAS RANGE IN THE KITCHEN LOCATED AT APT 1F, 2nd STORYJul 24, 2007

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 9:01 PM ET. BBL 4119660006.