5 floors · 23 apartments · 21,917 sq ft · built 1925 · class C6 · owner of record: Iiii Souther Blvd H D F C
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-26 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 12, 2009 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER. NOTED: THE STUCCO FINISH ALONG EXPOSURE 4 HAS FALLEN DOWN IN SEVERAL AREAS ALONG THE BUILDING SIDE EXPOSING THE BRICK. THE DEBRIS HAS FALLEN INTO THE PLA #34735349L | Apr 3, 2009 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 16, 2022 | CONSTRUCTION VIO22-50154 #E202AW | DOB VIOLATION - ACTIVE |
| Jan 19, 2007 | LOCAL LAW 62/91 - BOILERS #07045 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #09403 | DOB VIOLATION - ACTIVE |
| Mar 26, 2002 | LOCAL LAW 62/91 - BOILERS #10326 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 19, 2007 | Boiler LL6291 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Mar 26, 2002 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 5, 2008 | C | D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING BOTTOM SASH GLASS INTERMEDIATE LANDING 3RD TO 4TH STY PUB HALL STAIR ER1. | Jun 11, 2008 |
| Jun 5, 2008 | C | D26-10.01 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING METAL TREAD SOUTH FIRE ESCAPE FROM 1ST TO 2ND STY BALCONY ER1. | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 21 · D26-17.07 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2ND STY FRONT NORTHEAST APT 21 KITCHEN & BATHROOM. LOCATED AT APT 21 | Jun 11, 2008 |
| Jun 5, 2008 | C | D26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1ST STY PUB HALL & BOILER ROOM DOOR. | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 24 · D26-13.03 ADM CODE ABATE THE NUISANCE CONSISTING OF RODENTS RATS AT 2ND STY REAR WEST APT 24 KITCHEN ER1. , SECTION '' '' | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 3 · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLG 1ST STY NORTHWEST APT 3 KITCHEN ER1. LOCATED AT APT 3 | Jun 11, 2008 |
| Jun 5, 2008 | C | D26-11.01, 11.03, 11.05 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE SEWAGE & STAGNANT WATER CELLAR FRONT ER1. | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 43 · D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE STAMPED METAL CLG 4TH STY SOUTHWEST APT 43 KITCHEN ER1. LOCATED AT APT 43 | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 3 · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLG 1ST STY NORTHWEST APT 3 KITCHEN ER1. LOCATED AT APT 3 | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 35 · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ILLEGAL GAS SPACE HEAT CONNECTION FROM KITCHEN GAS METER 3RD STY NORTHWEST APT 35. LOCATED AT APT 35 | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 1 · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLG & WALLS BATHROOM 1ST STY NORTH APT 1 ER1. LOCATED AT APT 1 | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 1 · D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING WATER TANK FOR WATER CLOSET BATHROOM 1ST STY NORTH APT 1. LOCATED AT APT 1 | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 1 · D26-15.01 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES WATER CLOSET BATHROOM 1ST STY NORTH APT 1. LOCATED AT APT 1 | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 1 · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK ENTRANCE DOOR 1ST STY NORTH APT 1. LOCATED AT APT 1 | Jun 11, 2008 |
| Jun 5, 2008 | C | D26-10.01 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING METAL TREAD WEST FIRE ESCAPE 1ST TO 2ND STY BALCONY ER1. | Jun 11, 2008 |
| Jun 5, 2008 | A | D26-41.15 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. | Sep 8, 2008 |
| Jun 5, 2008 | C | Apt 23 · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLG 2ND STY REAR SOUTH APT 23 NORTHWEST ROOM CENTER ROOM FOYER & BATHROOM ER1. , SECTION '' '' | Jun 11, 2008 |
| Jun 5, 2008 | C | D26-11.01, 11.03, 11.05 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE SEWAGE CELLAR OIL TANK ROOM ER1. | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 21 · D26-17.07 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM 2ND STY SOUTH APT 21. , SECTION '' '' | Jun 11, 2008 |
| Jun 5, 2008 | C | D26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1ST STY PUB HALL & BOILER ROOM DOOR. | Jun 11, 2008 |
| Jun 5, 2008 | C | D26-11.01, 11.03, 11.05 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE SEWAGE & WATER CELLAR THROUGHOUT ER1. | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 21 · D26-17.07 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2ND STY EAST APT 21 BATHROOM & KITCHEN. LOCATED AT APT 21 | Jun 11, 2008 |
| Jun 5, 2008 | C | Apt 25 · D26-17.07 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2ND STY NORTH APT 25 BATHROOM & KITCHEN. , SECTION '' '' | Jun 11, 2008 |
| Aug 13, 2007 | A | Apt 1 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW COUNTER BALANCE , IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 16, 2007 |
| Aug 13, 2007 | A | Apt 1 · SECTION 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ; IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 16, 2007 |
| Aug 13, 2007 | B | Apt 1 · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE , IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 17, 2007 |
| Aug 13, 2007 | C | Apt 25 · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATHROOM TUB 2ND STY NORTH APT 25. , SECTION '' '' | Aug 19, 2007 |
| Aug 13, 2007 | C | Apt 2H · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLG 2ND STY WEST APT 2H CENTER ROOM. , SECTION '' '' | Aug 19, 2007 |
| Aug 13, 2007 | C | Apt 24 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLG 2ND STY WEST APT 24 KITCHEN. LOCATED AT APT 24 | Aug 19, 2007 |
| Aug 13, 2007 | C | SECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING 2ND TREAD FROM BOTTOM AT STAIR BETWEEN 3RD STY TO 4TH STY REAR FIRE ESCAPE ER1. | Aug 19, 2007 |
| Aug 13, 2007 | C | Apt 24 · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF RODENTS RAT EXCRETA 2ND STY WEST APT 24 KITCHEN. LOCATED AT APT 24 | Aug 19, 2007 |
| Aug 13, 2007 | C | SECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE 3RD STY TREAD FROM TOP AT STAIR BETWEEN 2ND STY NORTH COURT FIRE ESCAPE ER1. | Aug 19, 2007 |
| Aug 13, 2007 | C | SECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE 2ND FROM BOTTOM AT STAIR BETWEEN 4TH STY 5TH STY NORTH COURT FIRE ESCAPE ER1. | Aug 19, 2007 |
| Aug 13, 2007 | C | SECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE 4TH STY TREAD FROM TOP AT STAIR BETWEEN 4TH STY 5TH STY NORTH COURT FIRE ESCAPE ER1. | Aug 19, 2007 |
| Aug 13, 2007 | C | SECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE 3RD STY TREAD FROM TOP AT STAIR BETWEEN 4TH STY 5TH STY FRONT FIRE ESCAPE ER1. | Aug 19, 2007 |
| Jun 26, 1990 | C | Apt 24 · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CLG 2ND STY WEST APT 24 SOUTH ROOM MS RODRIGUEZ 893 6052. LOCATED AT APT 24 | Jul 16, 1990 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 9:26 PM ET. BBL 2027270039.