6 floors · 83 apartments · 39,455 sq ft · built 1925 · class D4 · owner of record: 111 W 16th St Owners Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 47 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 39,455 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-21 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 18, 2023 | Construction CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION # 390236660K ISSUED ON 06/08/2020, COMPLY WITH COMMISSIONER'S ORDER #39101636L | Jul 11, 2024 IN VIOLATION | $2,500 |
| Jun 8, 2020 | Construction CLASS - 1 OBSERVED 4 COMMERCIAL PAY PER USE DRYERS IN THE BASEMENT WITH IMPROPER MATERIALS FOR EXHAUST VENTING AS PER NYC FGC SECT 614 AND THE GAS CONNECTED WITH FLEXIBLE GAS CONNECTORS WHICH ARE IMPROPER MATERIALS, REPA #39023660K | Dec 3, 2020 IN VIOLATION | $1,250 |
| Jun 8, 2020 | Plumbing CLASS - 1 OBSERVED 4 COMMERCIAL GAS DRYERS IN THE BASEMENT WHICH ARE PAY PER USE IN OPERATION WITHOUT A REQUIRED FIRE SUPPRESSION SYSTEM . THE UTILITY COMPANY RESPONDED AND SHUT THE GAS TO THE DRYERS, PROVIDE A SYSTEM OF #39023659N | Dec 3, 2020 IN VIOLATION | $1,000 |
| Jul 17, 2018 | Construction CLASS - 2 TEMP CONST EQUIPMENT ON SITE-EXPIRED PERMIT-@TIME OF INSP NOTED SIDEWALK SHED PERMIT #140663841 EXPIRED ON 07/13/2018 NO VALID PERMIT FOR SIDEWALK SHED.REM:RENEW PERMIT. #35344662X | Sep 6, 2018 ADMIT/IN-VIO | $0 |
| Jun 28, 2017 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS. NOTED: AT FRONT APPROX 1'X1'X1' PIECE OF DECORATIVE COPING STONE DISLODGED & FELL TO SIDEWALK ON THE RIGHT SIDE OF MAIN ENTRY. REMEDY: MAKE SAFE IMMEDIATELY. COMPLY W/CODE,MAKE #35244778J | Nov 16, 2017 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Apr 29, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2000398 | DOB VIOLATION - ACTIVE |
| Dec 13, 2017 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00024 | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST #01115 | DOB VIOLATION - ACTIVE |
| Jun 1, 2016 | ELEVATOR #EVCAT580603 | DOB VIOLATION - ACTIVE |
| Jun 10, 2015 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST #00510 | DOB VIOLATION - ACTIVE |
| Aug 26, 2013 | ELEVATOR #9027/453603 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Apr 29, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Dec 13, 2017 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 3, 2017 | Elevators ACC1 | Active |
| Jun 1, 2016 | Elevators E | Active |
| Jun 10, 2015 | Elevators EVCAT1 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 22, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT BALCONY AT 2ND STORY AT 1ST FROM WEST AT FRONT AT FIRE ESCAPE | Aug 26, 2026 |
| Sep 9, 2025 | C | Apt 5E · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER UNIT INSTALLED AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 15, 2025 |
| Oct 2, 2024 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT .. AT FIRE ESCAPE | Jan 5, 2025 |
| Oct 2, 2024 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT NORTH WALL IN VESTIBULE , 1st STORY | Jan 5, 2025 |
| Sep 3, 2019 | C | Apt 1A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 24, 2019 |
| Date | Source | What | Now |
|---|---|---|---|
| Jul 22, 2026 | HPD B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT BALCONY AT 2ND STORY AT 1ST FROM WEST AT FRONT AT FIRE ESCAPE | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 7:59 PM ET. BBL 1007920028.