3 floors · 3 apartments · 3,135 sq ft · built 1899 · class C0 · owner of record: Herms, April
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 304 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 791 days | Next cycle year 2028 |
None open.
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 22, 2013 | I | SECTION 27-2089 ADM CODE ABOVE PREMISES HAVE BEEN VACANT AND UNTENANTED EXCEPT FOR CARETAKER FOR 60 DAYS OR MORE, AND CANNOT BE REOCCUPIED UNTIL A NEW CERTIFICATE OF OCCUPANCY HAS BEEN OBTAINED. PREMISES HAVE BEEN VACANT SINCE 09.22.2013 | — |
| Feb 26, 2007 | C | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM ....... AT PUBLIC HALL, 1st STORY | Mar 9, 2007 |
| Feb 12, 2007 | C | Apt 3FL · SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 3rd STORY | Feb 23, 2007 |
| Feb 12, 2007 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE KNOB AT DOOR ENTRANCE DOOR | Mar 24, 2007 |
| Feb 12, 2007 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK DEVICE AT METAL GATE ENTRANCE TO BUILDING | Mar 24, 2007 |
| Feb 12, 2007 | B | Apt 3FL · SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 3rd STORY | Mar 24, 2007 |
| Sep 15, 2006 | B | SECTION 233 M/D LAW REMOVE DOOR FROM CLOSET LEADING TO SCUTTLE OPENING IN ROOF AT PUBLIC HALL , 3rd STORY | Oct 25, 2006 |
| Sep 15, 2006 | A | SECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR .. AT PUBLIC HALL, 1st STORY | Dec 24, 2006 |
| Sep 15, 2006 | A | SECTION 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. | Dec 24, 2006 |
| Sep 15, 2006 | A | SECTION 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. | Dec 24, 2006 |
| Sep 15, 2006 | A | SECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX .. AT PUBLIC HALL, 1st STORY | Dec 24, 2006 |
| Sep 15, 2006 | B | SECTION 27-2089 ADM CODE THE PREMISES FORMERLY A VACANT BUILDING ARE NOW OCCUPIED BY OTHER THAN A CARETAKER WITHOUT OBTAINING A CERTIFICATE OF OCCUPANCY , TENANT LIVES IN 3RD STORY APARTMENT | Oct 25, 2006 |
| Sep 15, 2006 | C | SECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM .. AT PUBLIC HALL, 1st STORY | Sep 26, 2006 |
| Jan 31, 2006 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING , 100 WATTS REQUIRED. | Mar 12, 2006 |
| Jul 12, 2004 | C | SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LOOSE WOOD TREAD 6TH UP FROM BOTTOM AT STAIR AT CELLAR | Jul 23, 2004 |
| Jul 12, 2004 | B | SECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE WEST YARD | Aug 21, 2004 |
| Jul 12, 2004 | B | Apt 2 · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY | Aug 21, 2004 |
| Jul 12, 2004 | B | Apt 2 · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY | Aug 21, 2004 |
| Jul 12, 2004 | B | Apt 2 · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER BOARD CEILING IN THE FOYER LOCATED AT APT 2, 2nd STORY | Aug 21, 2004 |
| Jul 12, 2004 | A | Apt 2 · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING IN THE FOYER LOCATED AT APT 2, 2nd STORY | Oct 20, 2004 |
| Jul 12, 2004 | B | Apt 2 · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MOLD AND MILDEW AT CEILING IN THE BATHROOM LOCATED AT APT 2, 2nd STORY | Aug 21, 2004 |
| Jul 12, 2004 | B | Apt 2 · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2, 2nd STORY | Aug 21, 2004 |
| Dec 4, 2003 | B | Apt 1 · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE AT ENTIRE APARTMENT, 1st STORY, APARTMENT | Jan 13, 2004 |
| Dec 4, 2003 | B | Apt 1 · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES AT ENTIRE APARTMENT, 1st STORY, APARTMENT | Jan 13, 2004 |
| Dec 4, 2003 | C | Apt 1 · SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY | Dec 15, 2003 |
| Dec 4, 2003 | B | Apt 1 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING AT ENTIRE APARTMENT, 1st STORY, APARTMENT | Jan 13, 2004 |
| Dec 4, 2003 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELLS AT VESTIBULE AT PUBLIC HALL, 1st STORY | Jan 13, 2004 |
| Sep 5, 2003 | C | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BROKEN GLASS PANES [3 LITES] AT 3RD STORY WINDOW AT FROMT EXTERIOR WALL OVER ENTRANCE DOOR | Sep 16, 2003 |
| Jan 18, 2001 | C | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM. AT BOILER ROOM, CELLAR | Jan 29, 2001 |
| Jan 18, 2001 | C | Apt 2 FL · SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE KITCHEN LOCATED AT APT 2 FL, 2nd STORY | Jan 29, 2001 |
| Jan 26, 1999 | B | Apt 2 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE AT 2 STY APT 2 R BLACKWELL LOCATED AT APT 2 | Mar 15, 1999 |
| Jan 26, 1999 | B | Apt 2 · SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE AT 2 STY APT 2 LOCATED AT APT 2 | Mar 15, 1999 |
| Jan 26, 1999 | C | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BALUSTERS AT 2 STY PUBLIC HALL ER1 | Feb 15, 1999 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 1:00 AM ET. BBL 3016420040.