Manhattan · Block 276 · Lot 34 · 10002

110 Madison Street

6 floors · 24 apartments · 13,238 sq ft · built 1910 · class C7 · owner of record: 110 Madison Street Cc Llc

76open violations
$37,539ECB/OATH penalties owed
32HPD class C (immediately hazardous)
64dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 64 days
Annual
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-12-09 (Accepted). Agency page

Dec 31, 2026
in 64 days
3 of 3 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 80 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 308 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 795 days
Next cycle year 2028

Open violations

ECB / OATH (16) · $37,539 owed
IssuedViolationHearingBalance
Dec 23, 2022Boilers CLASS - 2
BOILER NOT OPERATING AUTOMATIC TO SUPPLY HEAT TO THE BUILDING/GAS PIOLIT IS DEFECTIVE/BOILER FRONT+REAR JACKET NOT IN PLACE/DEBRIS IN BOILER ROOM/FRONT LIGHT BULB IS DEFECTIVE;CORRECT VIOLATION AND SUBMIT THE C
#39076282L
Mar 2, 2023
DEFAULT
$0
Feb 25, 2020Construction CLASS - 1
REMOVED OR DEFACED A WRITTEN POSTED VACATE ORDER.NOTED:REMOVED VACATE ORDER#M197-2019 ISSUED ON 12/13/2019 NEW VACATE STICKER POSTED TO FRONT ENTRY OF PREMISES AND APT#20 FIFTH FLOOR.REM:COMPLY WITH CODE.
#35472882Y
Aug 12, 2021
IN VIOLATION
$2,500
Dec 13, 2019Construction CLASS - 1
FAILURE TO PROVIDE THE REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC1018.1(2008)BC1021.1(2014)AND 27-366 FOR TRANSIENT SRO USE AT APARTMENT #20 ON THE 5TH FLR.PREVIOUS VIO#35457865R.REM:DISCONTINUE
#35455439P
Jun 17, 2021
IN VIOLATION
$2,500
Dec 13, 2019Construction CLASS - 1
BC907.2.8/FAILURE TO PROVIDE THE REQUIRED FIRE ALARM SYSTEM FOR TRANSIENT SRO AT APARTMENT #20 ON THE 5TH FLR.PREVIOUS VIO#35457867K.REM:DISCONTINUE ILLEGAL OCCUPANCY.
#35455438N
Jun 17, 2021
IN VIOLATION
$2,500
Dec 13, 2019Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY NOTED AT APARTMENT #20ILLEGALLY CONVERTED SRO UNIT HOUSING FIRE ESCAPE STAIRS HAVING KEY LOCKING DEVICE ON DOOR.REM:REMOVE OBSTRUCTION.
#35455440M
Jun 17, 2021
IN VIOLATION
$1,250
Dec 13, 2019Quality of Life CLASS - 1
PERMANENT DWELLING USED CONVERTED FOR OTHER THAN PERMANENT RESIDENTIAL PURPOSES DOB RECORDS INDICTES PREMISES TO BE LEGALLY APPROVED AS A CLASS "A" MULTIPLE DWELLING APARTMENT #20 ON THE 5TH FLOOR IS NOW USED C
#35455446N
Jun 17, 2021
IN VIOLATION
$15,000
Dec 13, 2019Construction CLASS - 1
FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PERBC903.2 AND 27-954 FOR TRANSIENT SRO AT APARTMENT #20 ON THE 5TH FLR.PREVIOUS VIO#355457866Z.REM:DISCONTINUE ILLEGAL OCCUPANCY.
#35455437L
Jun 17, 2021
IN VIOLATION
$1,250
Nov 15, 2019Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER LAKC OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1 (2008 CODE) 27-366 BC 1021.1 2014 CODE FOR TRANSIENT USE FOUND AT APARTMENT 13 ON
#35457865R
Feb 25, 2021
IN VIOLATION
$2,500
Nov 15, 2019Construction CLASS - 1
907.2.8=FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE FOUND AT APARTMENT 13 ON THE 4TH FLOOR DISCONTINUE ILLEGAL OCCUPANCY
#35457867K
Feb 25, 2021
IN VIOLATION
$2,500
Nov 15, 2019Quality of Life CLASS - 2
PERMANENNT DWELLING USED/CONVERTED TO OTHEE THAN PERMANENT RESIDENTAL PURPOSES DEPARTMENT OF BUILDING RECORDS INDICATED THE PREMISES TO BE () CLASS "A" MULTIPLE DWELLING ILELGAL TRANSIENT USE NOTED #1 APARTMENT
#35457864P
Feb 25, 2021
IN VIOLATION
$2,500
Nov 15, 2019Construction CLASS - 1
FAILURE TO MAINTAIN BUIDLING IN CODE COMPLAINT MANNER LACK FO A SYSTEM OF AUTOMATIC SPRINKLER WHERE IS REQUIRED AS PER BC 903.2 AND 27-954 FOR TRANSIENT USE FOUND AT 4TH FLOOR APARTMENT 13 DISCONTINUE ILLEGAL O
#35457866Z
Feb 25, 2021
IN VIOLATION
$1,250
Oct 21, 2019Construction CLASS - 2
FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39007947H ISSUED ON 08-14-19 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. NO C OF C ON FILE. REMEDY: COMPLY W/COMM'S ORDER &/OR FILE A C
#35431321N
Apr 2, 2020
IN VIOLATION
$1,250
Oct 21, 2019Construction CLASS - 2
FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39007945Y ISSUED ON 08-14-19 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. NO C OF C ON FILE. REMEDY: COMPLY W/COMM'S ORDER &/OR FILE A C
#35431322P
Sep 17, 2020
IN VIOLATION
$625
Aug 14, 2019Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED, AT THE TIME OF INSPECTION OBSERVED VERY HIGH GAS SMELL IN THE BOILER ROOM IN CELLAR LEVEL DUE TO LAKE OF VENTILATION AND MISSING OF GAS DETECTOR. (F
#39007947H
Jan 30, 2020
IN VIOLATION
$1,250
Aug 14, 2019Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED, AT THE TIME OF INSPECTION OBSERVED BACK YARD FIREESCAPE PASSAGEWAY TO THE NEIGHBOR BUILDING CLOSED BY MASONRY WALLS HEIGHT MORE THEN 10 FT. CONTRARY TO I-
#39007945Y
Feb 6, 2020
IN VIOLATION
$664
Jul 30, 2018Boilers CLASS - 2
36,50A,50B,50C-AS PER CLASS 2(B254) 28-301.1 FAILURE TO MAINTAIN-36)BOILER NOT REGISTERED. 50A)SPILL SWITCH NOT INSTALLED. 50B)FLUE PIPING HUNG WITH PROHIBITED MATERIAL. 50C)BOILER ROOM DOOR NOT OPENING TOWARDS
#32097418J
Mar 7, 2019
IN VIOLATION
$0
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 3)
Active
HPD (72) · C 32 · B 35 · A 5
IssuedClassViolationCorrect by
May 22, 2026C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LEADING TO BASEMENT LOCKED AT BOILER ROOMMay 28, 2026
May 21, 2026CApt 6 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTMay 21, 2026
May 20, 2026BApt BASEME · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT BASEME, 1st APARTMENT FROM EAST AT SOUTHJun 24, 2026
May 20, 2026AApt BASEME · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT BASEME, 1st APARTMENT FROM EAST AT SOUTHAug 23, 2026
May 20, 2026CApt BASEME · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT BASEME, 1st APARTMENT FROM EAST AT SOUTHJun 3, 2026
May 19, 2026C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOMMay 25, 2026
May 14, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, 1st STORYJun 18, 2026
May 14, 2026BApt 24 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 24, 6th STORY, 2nd APARTMENT FROM WEST AT NORTHJun 18, 2026
May 14, 2026CApt 24 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 24, 6th STORY, 2nd APARTMENT FROM WEST AT NORTHMay 14, 2026
May 14, 2026C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT DOOR LEADING TO BASEMENT AT PUBLIC HALL, 1st STORYMay 20, 2026
May 14, 2026BApt 24 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 24, 6th STORY, 2nd APARTMENT FROM WEST AT NORTHJun 18, 2026
Mar 11, 2026BApt B · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT B, 1st BSMT-APT FROM NORTH AT EASTApr 15, 2026
Mar 11, 2026BApt B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT BSMT-APT B, 1st BSMT-APT FROM NORTH AT EASTApr 15, 2026
Mar 11, 2026CApt B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT B, 1st BSMT-APT FROM NORTH AT EASTApr 6, 2026
Mar 11, 2026BApt B · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT B, 1st BSMT-APT FROM NORTH AT EASTApr 15, 2026
Mar 11, 2026CApt B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT B, 1st BSMT-APT FROM NORTH AT EASTApr 6, 2026
Mar 11, 2026BApt B · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT SINK IN THE KITCHEN LOCATED AT BSMT-APT B, 1st BSMT-APT FROM NORTH AT EASTApr 15, 2026
Feb 2, 2026C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM AT BASEMENTFeb 8, 2026
Aug 6, 2025BApt BSMT · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHSep 10, 2025
Aug 6, 2025BApt BSMT · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION DRAIN LINE AT SINK IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHSep 10, 2025
Aug 6, 2025AApt BSMT · § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE MOLD ON GROUT AT NORTH WALL IN THE 2nd BATHROOM FROM NORTH LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHNov 9, 2025
Aug 6, 2025BApt BSMT · 566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF FLIES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHSep 10, 2025
Aug 6, 2025CApt BSMT · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHSep 1, 2025
Aug 6, 2025AApt BSMT · § 27-2026 ADM CODE REPAIR LEAKY WATER CLOSET FLUSH PIPE CONNECTION ... IN THE 2nd BATHROOM FROM NORTH LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHNov 9, 2025
Aug 6, 2025BApt BSMT · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd BATHROOM FROM NORTH LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHSep 10, 2025
Aug 6, 2025BApt BSMT · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHSep 10, 2025
Aug 6, 2025BApt BSMT · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD BASE CABINET AT EAST WALL IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHSep 10, 2025
Aug 28, 2024BApt BSMT · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FROM EAST LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHOct 2, 2024
Aug 28, 2024CApt BSMT · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHSep 23, 2024
Aug 28, 2024BApt BSMT · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF VERMIN FLIES IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHOct 2, 2024
Aug 28, 2024CApt BSMT · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHSep 23, 2024
Aug 28, 2024BApt BSMT · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING SEALER AT SADDLE IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHOct 2, 2024
Aug 28, 2024BApt BSMT · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHOct 2, 2024
Aug 28, 2024BApt BSMT · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CLOSET DOOR AT SOUTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHOct 2, 2024
Aug 28, 2024BApt BSMT · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING SEALER AT SADDLE IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHOct 2, 2024
Aug 28, 2024BApt BSMT · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WATER SUPPLY PIPE TO WATER CLOSET IN THE 2nd BATHROOM FROM EAST LOCATED AT BSMT-APT BSMT, 1st BSMT-APT FROM EAST AT SOUTHOct 2, 2024
Jun 7, 2024CApt 20 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT THE CEILING IN THE KITCHEN LOCATED AT APT 20, 5th STORY, 2nd APARTMENT FROM WEST AT NORTHJun 13, 2024
Jun 7, 2024CApt 20 · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WOODEN UPPER WALL CABINETS AT THE SOUTH WALL IN THE KITCHEN LOCATED AT APT 20, 5th STORY, 2nd APARTMENT FROM WEST AT NORTHJun 13, 2024
May 28, 2024CApt 20 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT THE CEILING IN THE 4th ROOM FROM EAST LOCATED AT APT 20, 5th STORY, 2nd APARTMENT FROM WEST AT NORTHJun 3, 2024
Jan 8, 2024BApt 21 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 21, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTFeb 12, 2024
Jan 8, 2024CApt 21 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 21, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTJan 7, 2024
Jan 8, 2024BApt 21 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 21, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTFeb 12, 2024
Mar 7, 2023BApt 21 · § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE RADIATOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 21, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTApr 11, 2023
Mar 7, 2023CApt 21 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 21, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTMar 7, 2023
Mar 7, 2023C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BASEMENT AT BOILER ROOMMar 13, 2023
Jan 27, 2023CApt 21 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM NORTH LOCATED AT APT 21, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTJan 26, 2023
Jan 27, 2023C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOMFeb 2, 2023
Jan 17, 2023CApt 19 · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 19, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 31, 2023
Jan 17, 2023CApt 19 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO FIRE ESCAPE WINDOW IN THE 3rd ROOM FROM NORTH LOCATED AT APT 19, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 23, 2023
Jan 3, 2023C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOMJan 9, 2023
Dec 19, 2022C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM : DOOR LOCKED. SUPER NOT AVAILABLE AT BOILER ROOMDec 25, 2022
Dec 5, 2022CApt 10 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 10, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTDec 31, 2022
Jul 14, 2022AApt 23 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS THROUGH-OUT IN THE ENTIRE APARTMENT LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 17, 2022
Jul 14, 2022CApt 23 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 9, 2022
Jul 14, 2022BApt 23 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 18, 2022
Jul 14, 2022BApt 23 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 18, 2022
Jul 14, 2022BApt 23 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD PARQUET FLOOR TILES IN THE 1st ROOM FROM EAST LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 18, 2022
Jul 14, 2022AApt 23 · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 17, 2022
Jul 14, 2022BApt 23 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 18, 2022
Jul 14, 2022BApt 23 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BASE CABINET AT NORTH WALL IN THE KITCHEN LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 18, 2022

Showing 60 of 72. Full list on the agency site.