6 floors · 25 apartments · 20,798 sq ft · built 1900 · class C6 · owner of record: 110 Forsyth Street Hdfc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 62 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 78 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 306 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 793 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-18 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 18, 2025 | Construction CLASS - 2 UNABLE TO GAIN ACCESS. CERTIFICATE OF CORRECTION NOT SUBMITTED FOR CLASS 1 FAILURE TO MAINTAIN VIOLATION #35665694H ISSUED ON 11/16/2022 FOR LACK OF FIRE ALARM SYSTEM FOR TRANSIENT USE OF APARTMENT #18., FILE A #39170795H | Jan 21, 2027 DEFAULT | $1,280 |
| Dec 18, 2025 | Construction CLASS - 2 UNABLE TO GAIN ACCESS. CERTIFICATE OF CORRECTION NOT SUBMITTED FOR CLASS 1 FAILURE TO MAINTAIN VIOLATION #35665695J ISSUED ON 11/16/2022 FOR REQUIRED MEANS OF EGRESS AT APARTMENT #2 TRANSIENT USED SPACE., FILE #39170797L | Mar 26, 2026 IN VIOLATION | $1,250 |
| Dec 18, 2025 | Construction CLASS - 2 UNABLE TO GAIN ACCESS. CERTIFICATE OF CORRECTION NOT SUBMITTED FOR CLASS 1 FAILURE TO MAINTAIN VIOLATION #35665696L ISSUED ON 11/16/2022 FOR LACK OF AUTOMATIC SPRINKLER SYSTEM FOR TRANSIENT USE OF APARTMENT #18 #39170796J | Jan 21, 2027 DEFAULT | $1,280 |
| Nov 16, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.FAILURE TO PROVIDE #OF REQ MEANS OF EGRESS FOR EVERY FL PER BC1018.1&27-366 FOR TRANSIENT USE IN APT18.DISCONT ILLEGAL USE #35665695J | Mar 23, 2023 IN VIOLATION | $0 |
| Nov 16, 2022 | Quality of Life CLASS - 2 PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALPURPOSES.DOB RECORDS INDICATE PREMISES LEGALLY APPROVED AS CLASSA MULTIPLE DWELLING.NOW APT18 USED/CONVERTED TO TRANSIENT USE FOR 2GUEST (EN #35665693X | Aug 10, 2023 ADMIT/IN-VIO | $0 |
| Nov 16, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.LACK OF AUTOMATIC SPRINKLER SYSTEM.WHERES REQ AS PER BC903.2&27-954 FOR TRANSIENT USE IN APT18 DISCONT ILLEGAL USE #35665696L | Mar 23, 2023 IN VIOLATION | $0 |
| Nov 16, 2022 | Construction CLASS - 1 BC907.2.8 FAILURE TO PROVIDE A FIRE ALARM SYSTEM FOR TRANSIENT USE IN APT18 DISCONT ILLEGAL USE #35665694H | Mar 23, 2023 IN VIOLATION | $0 |
| Jul 10, 2019 | Unknown CLASS - 2 FAILURE TO POST OR DISTRIBUTE TENANT PROTECTION PLAN., POST OR DISTRIBUTE NOTICE OF TPP; COMPLY WITH CODE #39005317Y | Dec 5, 2019 IN VIOLATION | $0 |
| Jun 23, 2018 | Construction CLASS - 1 WORK W/O A PERMIT. ON 6-23-18 @ APPROX 10AM I OBSERVED IN THE CELLAR AN ACTIVE GAS METER W/NEW GAS PIPING & GAS FITTINGS INSTALLED ON AN EXPIRED PERMIT. WHICH IS NOT CODE COMPLIANT. REMEDY: OBTAIN ALL REQUIRED #35269560H | Aug 9, 2018 IN VIOLATION | $0 |
| Jun 23, 2018 | Plumbing CLASS - 1 GAS BEING SUPPLIED TO BLDG W/O INSPECTION & CERTIFICATION BY DOB. ON 6-23-18 @ APPROX 10AM I OBSERVED IN THE CELLAR AN ACTIVE GAS METER SUPPLYING GAS TO COMMERCIAL GAS EQUIPMENT ON THE 1ST FL DELI W/O ANY GAS #35269559K | Aug 9, 2018 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00095 | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00094 | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00096 | DOB VIOLATION - ACTIVE |
| Jun 8, 2000 | ZONING #MTF04M | DOB VIOLATION - ACTIVE |
| Jun 8, 2000 | CONSTRUCTION #MTF05M | DOB VIOLATION - ACTIVE |
| Jul 22, 1997 | CONSTRUCTION #MTF6RI | DOB VIOLATION - ACTIVE |
| Jul 22, 1997 | ZONING #MTF5RI | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 3) | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 29, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 2, 2026 |
| Jun 4, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 7, 2025 |
| Apr 1, 2024 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 5, 2024 |
| Mar 15, 2023 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jun 18, 2023 |
| Feb 15, 2022 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | May 21, 2022 |
| Apr 1, 2021 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 5, 2021 |
| Jul 28, 2020 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORY | Oct 31, 2020 |
| Jul 28, 2020 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Oct 31, 2020 |
| Dec 26, 2018 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND WALLS AT PUBLIC HALL, 1st STORY | Mar 31, 2019 |
| Dec 26, 2018 | B | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 30, 2019 |
| Dec 26, 2018 | B | Apt 1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BASEBOARD MOLDING AT SOUTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 30, 2019 |
| Dec 26, 2018 | B | Apt 1 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 30, 2019 |
| Dec 26, 2018 | B | Apt 1 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 30, 2019 |
| Dec 26, 2018 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILINGS AND WALLS THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 30, 2019 |
| Dec 26, 2018 | C | Apt 2 · § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF KEY OPERATED LOCK INSTALLED ON DOOR LEADING TO THE FIRE ESCAPE WINDOW IN THE 1st ROOM FROM NORTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 3, 2019 |
| Dec 26, 2018 | B | Apt 2 · § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS , IN THE ENTRANCE LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 30, 2019 |
| Dec 26, 2018 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THE FIRE REATARANT PLASTER AT CEILING AND WALLS AT PUBLIC HALL, 1st STORY | Jan 30, 2019 |
| Nov 28, 2016 | A | SECTION 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY | Mar 3, 2017 |
| Nov 28, 2016 | A | SECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR .. AT PUBLIC HALL, 1st STORY | Mar 3, 2017 |
| Nov 28, 2016 | C | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT THE BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Dec 6, 2016 |
| Nov 28, 2016 | C | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT THE VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Dec 6, 2016 |
| Nov 28, 2016 | B | SECTION 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LATCH AND LOCKSET AT THE BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Jan 2, 2017 |
| Nov 28, 2016 | B | SECTION 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LATCH AND LOCKSET AT THE VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Jan 2, 2017 |
| Nov 28, 2016 | A | SECTION 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Mar 3, 2017 |
| Nov 28, 2016 | A | SECTION 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY | Mar 3, 2017 |
| Nov 28, 2016 | A | SECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Mar 3, 2017 |
| Nov 28, 2016 | A | SECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX .. AT PUBLIC HALL, 1st STORY | Mar 3, 2017 |
| Aug 15, 2016 | A | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX - MISSING AT PUBLIC HALL, 1st STORY | Nov 18, 2016 |
| Aug 15, 2016 | C | SECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM - MISSING AT PUBLIC HALL, 1st STORY | Aug 23, 2016 |
| Aug 15, 2016 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. | Nov 18, 2016 |
| Aug 15, 2016 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. | Nov 18, 2016 |
| Aug 15, 2016 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. | Nov 18, 2016 |
| Aug 15, 2016 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. | Nov 18, 2016 |
| Aug 15, 2016 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR - MISSING AT PUBLIC HALL, 1st STORY | Nov 18, 2016 |