Brooklyn · Block 6371 · Lot 44 · 11214

11 Bay 20 Street

3 floors · 17,293 sq ft · built 2019 · class K4 · owner of record: Bay 20th Llc

0open violations
$52,187ECB/OATH penalties owed
0HPD class C (immediately hazardous)
415dto Gas piping inspection (2027 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 50 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 415 days
Next cycle year 2027

Open violations

ECB / OATH (19) · $52,187 owed
IssuedViolationHearingBalance
Jan 25, 2022Construction CLASS - 1
FAILURE TO COMPLY W/MANUFACTURER SPECIFICATIONS.NOTE:AT THE TIME OF INSPECTION OF A 3 STORY NEW BLDG CONSTRUCTION.I OBSERVED 70 DOCK BARRIERIN ROADWAY FOR A TEMPORARY PEDESTRIAN WALKWAY.UPON INSPECTION I OBSERV
#35639273K
Jun 8, 2022
IN VIOLATION
$2,500
Jun 21, 2020Construction CLASS - 2
FAILURE TO SAFEGUARD. AT TIME OF MY INSPECTION I OBSERVED THE JOBSITE GATE WAS NOT LOCKED OR SECURED CREATING A HAZARDOUS CONDITION-ACCESS TO CONSTRUCTION SITE TO PUBLUC. REMEDY: LOCK ENTRY GATE.
#35475120L
Jun 13, 2022
IN VIOLATION
$1,250
Jun 12, 2020Unknown CLASS - 1
PERMIT HOLDER FAILED TO ENSURE WORKERS RECEIVE SITE SAFETY ORITENTATION. NOTE: AT THE TIME OF MY INSPECTION OF A 3 STY NEW BLDG CONSTRUCTION IN PROGRESS. UPON REQUEST FOR SITE SAFETY ORIENTATION FOR EACH WORKER
#35481258P
Jan 24, 2022
IN VIOLATION
$5,000
Jun 12, 2020Construction CLASS - 1
SEC. 3307.4 WORK & STORAGE ZONE. NOTE: AT THE TIME OF MY INSPECTION OFA 3 STY NEW BLDG CONSTRUCTION IN PROGRESS,I OBSERVED DELIVERY TRUCK IN ROADWAY & ON SIDEWALK DROPPING STEEL INTO SITE. AT EXP#1 GRADE LEVEL
#35481257N
Jan 24, 2022
IN VIOLATION
$2,500
Jun 12, 2020Construction CLASS - 2
SEC. 3301.6.1 DESIGN. NOTE: AT THE TIME OF MY INSPECTION OF A 3 STY NEW BLDG CONSTRUCTION IN PROGRESS,I OBSERVED 2 WORK PLATFORM CONSTRUCTEDOF WOOD. UPON REQUEST FOR DESIGN DRAWINGS FOR PLATFORMS NONE WERE PROV
#35481259R
Jan 24, 2022
IN VIOLATION
$1,250
Jun 12, 2020Construction CLASS - 1
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS. NOTE: AT THE TIME OF MY INSPECTION OF A 3 STY NEW BLDG IN PROGRESS,UPON REVIEW OF SOE PLANS THE RAKERS WERE NOT IN PLACE AS PER
#35481256L
Jan 24, 2022
IN VIOLATION
$1,250
Oct 17, 2019Construction CLASS - 1
BC3301.2/FAILURE TO MAINTAIN/INSTITUTE SAFET MEASURES DURING CONSTRUCTION. NOTED:AT TIME OF MY INSPECTIONOF ANEW 3 STORIE BUILDING AT EXCAVATION PHASE I OBSERVED THE FOLLOWING VIOLATING CONDITIONS.UNCAPPED AND
#35461667H
Jan 21, 2022
IN VIOLATION
$2,500
Oct 17, 2019Construction CLASS - 1
BC307.5/FLAG PERSON(NONE)NOTED;AT TIME OF MY INSPECTION OF A NEW 3 SOTRIE BUILDING AT EXCAVATION PHASE,I OBSERVED AN CONCRETE MISER TRUCK AND A CONCRETE PUMB TRUCK OBSTRUCTING THE STREET OUTSIDE THE ABOVE JOB W
#35461668J
Sep 17, 2021
IN VIOLATION
$2,500
Oct 17, 2019Construction CLASS - 2
FAILURE TO POST PERMIT FOR WORK AT PREMISES.NOTED:AT TIME OF MY INSPECTION OF A NEW 3 STORIE BUILDING EXCAVATION PHASE,I OBSERVED THAT NO PERMITS(DOT AND D.O.B)HAD BEEN POSTED ANYWHERE ALONG THE PERIMETER/CONST
#35461669L
Sep 17, 2021
IN VIOLATION
$312
Oct 17, 2019Construction CLASS - 1
WORK DOES NOT CONFORM TO APPROVED DOCUMENTS AND OR AMENDMENTS.NOTE:AT TIME OF MY INSPECTION OF A NEW 3 STORIE BUILDING AT EXCAVATION PHASE IOBSERVED STEEL WORK PROVIDING SUPPORT FOR THE S.O.E UPON REVIEW OF THE
#35461666X
Jan 21, 2022
IN VIOLATION
$625
Oct 17, 2019Construction CLASS - 2
BC3301131-SITE SAFETY PLAN.AT TIME OF INSPECTION OF A NEW 3 STORIE BUILDING AT EXCAVATION PHASE,I OBSERVED A CONCRET PUMP TRUCK AND A CONCRETE MIXER TRUCK ON THE STREET AT EXPOSURE#1 PUMPING CONCRETE ONTO THE S
#35461671K
Jul 19, 2021
IN VIOLATION
$625
May 31, 2019Construction CLASS - 1
FAILURE TO NOTIFY THE DEPARTMENT OF AN INCIDENT THAT RESULTED IN ON FATALITY OR INJURY.A WORKER FELL SIXTEEN FEET INTO ELEVATOR SHAFT.HE SUFFERED A BROKEN LEG AND WAS TRANSPORTED TO A HOSPITAL.AS PER USUAL THE
#35440189J
Dec 16, 2019
DEFAULT
$12,500
May 31, 2019Construction CLASS - 2
33.2.4;FAILURE TO PROVIDE SANITORY FACILITY ADEQUATELY NOTE:ANSL Z 4.3-AT TIME OF INSPECTION I OBSERVED TAHT THERE WAS SANITORY FACILITY (PORTER JOB) ON SITE OVERFLOWING WITH (FILTH) WHICH POSES A HEALTH HAZARD
#35437127R
Sep 17, 2020
IN VIOLATION
$625
May 31, 2019Unknown CLASS - 1
FAILURE TO MAINTAIN SAFETY MEASURES AT JOB SITE AS REQUIRED NO PRE SHIFT MEETING LOG NOTE:AT TIME OF INSPECTION OF A 3 STORY NEW BUILDING RESPONDING TO AN INCLUDED WHERE A WORKER FEEL 16 FEET INJURING HIS LOGS
#35418473X
Sep 17, 2020
IN VIOLATION
$2,500
May 31, 2019Construction CLASS - 2
FAILURE TO PROVIDE JOB SITE FENCE A REQUIRED MISSING.NOTE:AT TIME OF INSPECTION RESPONDING TO AN INCIDENT I OBSERVED THAT THERE WAS MISSING JOB SITE FENCE AT EXPOSURE #3 THIS CREATES A HAZARDOUS CONDITION SINCE
#35437125N
Sep 17, 2020
IN VIOLATION
$5,000
Mar 21, 2019Construction CLASS - 2
FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.NOTE:@TIME OF MY INSPECTION OBSERVED THE SIDEWALK WITH CRACKS AND HOLES AND UN EVEN SURFACE THIS CREATING A HAZARD CONDTIONS FOR
#35363982Z
Jul 1, 2019
IN VIOLATION
$5,000
Mar 14, 2019Construction CLASS - 1
3304.7 REQUIRED MEANS OF EGRESS.AT THE TIME OF INSPECTION OF A NEW 3 STORY BUILDING UNDER CONSTRUCTION OF EXCAVATION STAGE ACTIVE JOBSITEI OBSERVED INADEQUATE MEANS OF EGRESS AT EXCAVATION SITE. THIS CONDIT
#35382871J
Jun 24, 2019
IN VIOLATION
$2,500
Oct 11, 2018Construction CLASS - 1
UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT.AT THE TIME OF INSPECTION PLASTIC CANISTER FILLED WITH GASOLINE STORED ON SITE NEAR WELDING MACHINE IN USE WAS OBSERVED.OXYGEN AND ACETYLN TANKS OBSERVED LAY
#35354045J
May 1, 2019
IN VIOLATION
$2,500
Oct 11, 2018Construction CLASS - 2
BC28-407.1.UNLAWFULLY PERFORMING WELDING WITHOUT A WELDING CERTIFICATION AT THE TIME OF INSPECTION WORKERS OBSERVED WELDING SUPPORT OF EXCAVATION RAKERS AND WALERS WITHOUT A WELDING CERTIFICATION.WELDING CERTIF
#35354043X
May 1, 2019
IN VIOLATION
$1,250
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 5:34 PM ET. BBL 3063710044.