8 floors · 31 apartments · 27,128 sq ft · built 2025 · class D1 · owner of record: 11-32 31 Drive Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 27,128 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 798 days | Next cycle year 2028 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | Feb 21, 2029 in 850 days | Filing window not open yet |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 17, 2026 | Construction CLASS - 2 PROPOSED 8 STORY NEW BUILDING. OBSERVED ERECTED SIDEWALK SHED WITH POSTED PERMIT NUMBER Q01223259-I1-SH EXPIRED AT 09/08/2026 UPON REQUEST FOR NEW PERMIT NON WAS PROVIDED AND AFTER FURTHER REVIEW ON DOB NOW NO #39559313L | Nov 24, 2026 PENDING | $1,250 |
| Aug 3, 2026 | Construction CLASS - 2 OBSERVED ACTIVE 8 STORY NB WITH SWS & SUPPORTED SCAFFOLD INSTALLED @ EXPO 1. SUPPORTED SCAFF IS ALSO INSTALLED ON EXPO 3. UPON REQUEST OF INITIAL INSTALLATION LETTER FOR SUPPORTED SCAFFOLD & SWS, NO LETTERS WER #39557443K | Oct 13, 2026 DEFAULT | $1,280 |
| Aug 3, 2026 | Unknown CLASS - 2 3301.1.2: OBSERVED ACTIVE 8 STORY NB WITH SWS AND SUPPORTED SCAFFOLD INSTALLED ON EXPO 1. MAIN STANDPIPE INSTALLED THROUGHOUT EVERY FLOOR AND HAS BEEN PAINTED RED. UPON REQUEST OF HYDROSTATIC PRESSURE TEST, NO #39557442Z | Oct 13, 2026 DEFAULT | $2,530 |
| Jul 17, 2026 | Construction CLASS - 2 DURING INSPECTION IN REGARDS TO INCIDENT THAT TOOK PLACE WHERE 2 UNAUTHORIZED PERSONS WITH NO AFFILIATION TO THE SITE ENTERED UNNOTICED BY SECURITY/ PERSONNEL PRIOR TO CREATING AN ALLEGED INJURY INCIDENT ON THE #39556781Z | Nov 17, 2026 PENDING | $5,000 |
| Jul 17, 2026 | Construction CLASS - 1 IN RESPONSE TO AMBULANCE BEING CALLED TO THE SITE ON JULY 10TH 2026 REVIEW OF CS LOG BOOK CONFIRMS THAT 2 UNAUTHORIZED PERSONS ENTERED THE SITE SAT DOWN, CALLED, AND LEFT IN AN AMBULANCE. GC DID NOT IMMEDIATELY #39556780R | Nov 17, 2026 | $5,000 |
| Jun 10, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33.-AS NOTED AT TIME OF INSPECTION OF AN ACTIVE JOB-SITE OF 8 STORY NEWBUILDING AT BULKHEAD LEVEL(COMPLETED), I OBSERVED THE CONCRETE SHEAR W #35729982M | Nov 24, 2026 PENDING | $1,250 |
| Jun 9, 2026 | Construction CLASS - 2 PROPOSED 8 STORY NEW BUILDING. OBSERVED ERECTED SUPPORTED PIPE SCAFFOLD ON TOP OF SIDEWALK SHED AT EXP#1, WHEN REQUESTED FOR LOAD IMPOSED LETTER AS REQUIRED BY 3314.3.4 AND INSTALLATION INSPECTION LETTER AS REQ #39555269P | Nov 24, 2026 PENDING | $1,250 |
| Apr 6, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED: STANDPIPE ALARM IN PLACE AT GROUND LEVEL IN A PROPOSED 8 STORY NEW BUILDING TOP OFF. UPON REVIEWING DEPARTMENT RECORDS IT APPEARED NO ELECTRICAL PERMIT FOR STANDPIPE ALARM SYSTEM #39552653X | Mar 16, 2027 | $1,250 |
| Apr 6, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED: INADEQUATE STORAGE ZONE EXPO# 1 CONTAINER DEBRIS LOADED IN PROGRESS WITHOUT PROPER ENCLOSURE NO 4' CONTINUES BARRIER AND WIRE SCREEN THE SPACE BETWEEN THE BARRIER AND DECK OF SID #39552654H | Mar 16, 2027 | $2,400 |
| Apr 6, 2026 | Unknown CLASS - 2 3303.12: ELEVATORS AND HOISTS DURING CONSTRUCTION OR DEMOLITION. AT TIME OF INSPECTION OBSERVED: PROPOSED 8 STORY NB TOP OFF 85' APPROX. CCD1 ELEVATOR IN READINESS NOT IN COMPLIANCE WITH ALL 14 STIPULATIONS, CR #39552656L | Mar 16, 2027 PENDING | $2,500 |
| Apr 6, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED AT EXPOSURE 1 NO MIRRORS AT LOCATIONS WHERE PEDESTRIANS VIEW IS OBSTRUCTED BY WOOD COLUMNS AT SIDEWALK AREA CONTRARY TO BC 3307.2.6. NUMERAL 3 CREATING A POTENTIAL #39552655J | Mar 16, 2027 | $2,500 |
| Apr 6, 2026 | Unknown CLASS - 1 BC 3303.2.1 EXISTING SERVICES. AT TIME OF INSPECTION OBSERVED: POWER LINE INADEQUATE/NO PROTECTION AT EXPOSURE# TOUCHING SUPPORTED SCAFFOLD, WIRES EXPOSED, NOT PROTECTED, CREATING A POTENTIAL ELECTRICAL SHOCK C #39552651M | Mar 16, 2027 | $5,000 |
| Apr 6, 2026 | Unknown CLASS - 2 3314.4.8 MAINTENANCE. AT TIME OF INSPECTION OBSERVED: SUPPORTED SCAFFOLD CONTRARY TO CODE INSTALLED AT EXPOSURE# 1-3. MISSING SECTIONS OF GUARDRAILS, LOOSE PLANKS, CREATING UNSAFE CONDITION. STOP ALL USE SUPPOR #39552652Y | Mar 16, 2027 | $2,500 |
| Mar 18, 2026 | Construction CLASS - 1 3305.3.6.1.2 FAILURE TO SECURE RESHORES IN PROXLIMITY TO ENCLOSED PERIMETERS AS NOTED:AT TIME OF INSPECTION ON AN ACTIVE JOBSITE FOR A PROPOSED 8 STORY BUILDING OBSERVED AT CONCRETE DECK ON FLOOR#5 AT EXPOSURE #35726573H | Apr 8, 2027 DEFAULT | $2,530 |
| Mar 18, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENT.AS NOTED:AT TIME OF INSPECTION AT AN ACTIVE JOBSITE FOR A PROPOSED 8 STORYCONCRETE BUILDING OBSERVED CONCRETE WASHOUT WATER AND CONCRETE REMNANT #35726450H | Apr 8, 2027 DEFAULT | $2,530 |
| Jan 21, 2026 | Unknown CLASS - 2 PROPOSED 8 STORY BUILDING. ACTIVE CONCRETE OPERATIONS OBSERVED PORTABLE FUEL FIRE HEATERS AT 2FL. WHEN REQUESTED FOR FDNY PERMIT & CERTIFICATE OF FITNESS S92&S93 NONE WERE PROVIDED. TEMPORARY LADDER WITHOUT NON #39549375H | Nov 23, 2026 PENDING | $0 |
| Jan 21, 2026 | Construction CLASS - 2 PROPOSED 8 STORY BUILDING. OBSERVED ACTIVE CONCRETE OPERATIONS WITH MIXER AND CONCRETE PUMP TRUCK ON STREET WITHOUT ANY BARRIERS. UPON REVIEWING THE SITE SAFETY PLANS IT SHOWS FULLY ENCLOSED INTERLOCKED JERSEY #39549379P | Nov 23, 2026 | $1,250 |
| Dec 20, 2025 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OBSERVED PEDESTRIAN WALKWAY ON STREET NOT MAINTAINED/INSTALLED PER CODE-JERSEY BARRIERS NOT FULLY INSTALLED(SPACING BETWEEN BARRIERS),NOT CONNECTED TOGETHER,NOT FILLED OUT WITH WATE #39548197J | Dec 31, 2026 DEFAULT | $2,430 |
None open.
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 17, 2026 | ECB | Construction: PROPOSED 8 STORY NEW BUILDING. OBSERVED ERECTED SIDEWALK SHED WITH POSTED PERMIT NUMBER Q01223259-I1-SH EXPIRED AT 09/08/2026 UPON REQUEST FOR NEW PERMIT NON WAS PROVIDED AND AFTER FURTHER REVIEW ON DOB NOW NO | Open |
| Aug 3, 2026 | ECB | Construction: OBSERVED ACTIVE 8 STORY NB WITH SWS & SUPPORTED SCAFFOLD INSTALLED @ EXPO 1. SUPPORTED SCAFF IS ALSO INSTALLED ON EXPO 3. UPON REQUEST OF INITIAL INSTALLATION LETTER FOR SUPPORTED SCAFFOLD & SWS, NO LETTERS WER | Open |
| Aug 3, 2026 | ECB | Unknown: 3301.1.2: OBSERVED ACTIVE 8 STORY NB WITH SWS AND SUPPORTED SCAFFOLD INSTALLED ON EXPO 1. MAIN STANDPIPE INSTALLED THROUGHOUT EVERY FLOOR AND HAS BEEN PAINTED RED. UPON REQUEST OF HYDROSTATIC PRESSURE TEST, NO | Closed |
| Jul 17, 2026 | ECB | Construction: DURING INSPECTION IN REGARDS TO INCIDENT THAT TOOK PLACE WHERE 2 UNAUTHORIZED PERSONS WITH NO AFFILIATION TO THE SITE ENTERED UNNOTICED BY SECURITY/ PERSONNEL PRIOR TO CREATING AN ALLEGED INJURY INCIDENT ON THE | Open |
| Jul 17, 2026 | ECB | Construction: IN RESPONSE TO AMBULANCE BEING CALLED TO THE SITE ON JULY 10TH 2026 REVIEW OF CS LOG BOOK CONFIRMS THAT 2 UNAUTHORIZED PERSONS ENTERED THE SITE SAT DOWN, CALLED, AND LEFT IN AN AMBULANCE. GC DID NOT IMMEDIATELY | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 12:03 AM ET. BBL 4005020023.