Queens · Block 502 · Lot 23 · 11106

11-32 31 Drive

8 floors · 31 apartments · 27,128 sq ft · built 2025 · class D1 · owner of record: 11-32 31 Drive Llc

7open violations
$42,450ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 67 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 83 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 27,128 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 188 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 188 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 798 days
Next cycle year 2028
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page

Feb 21, 2029
in 850 days
Filing window not open yet

Open violations

ECB / OATH (18) · $42,450 owed
IssuedViolationHearingBalance
Sep 17, 2026Construction CLASS - 2
PROPOSED 8 STORY NEW BUILDING. OBSERVED ERECTED SIDEWALK SHED WITH POSTED PERMIT NUMBER Q01223259-I1-SH EXPIRED AT 09/08/2026 UPON REQUEST FOR NEW PERMIT NON WAS PROVIDED AND AFTER FURTHER REVIEW ON DOB NOW NO
#39559313L
Nov 24, 2026
PENDING
$1,250
Aug 3, 2026Construction CLASS - 2
OBSERVED ACTIVE 8 STORY NB WITH SWS & SUPPORTED SCAFFOLD INSTALLED @ EXPO 1. SUPPORTED SCAFF IS ALSO INSTALLED ON EXPO 3. UPON REQUEST OF INITIAL INSTALLATION LETTER FOR SUPPORTED SCAFFOLD & SWS, NO LETTERS WER
#39557443K
Oct 13, 2026
DEFAULT
$1,280
Aug 3, 2026Unknown CLASS - 2
3301.1.2: OBSERVED ACTIVE 8 STORY NB WITH SWS AND SUPPORTED SCAFFOLD INSTALLED ON EXPO 1. MAIN STANDPIPE INSTALLED THROUGHOUT EVERY FLOOR AND HAS BEEN PAINTED RED. UPON REQUEST OF HYDROSTATIC PRESSURE TEST, NO
#39557442Z
Oct 13, 2026
DEFAULT
$2,530
Jul 17, 2026Construction CLASS - 2
DURING INSPECTION IN REGARDS TO INCIDENT THAT TOOK PLACE WHERE 2 UNAUTHORIZED PERSONS WITH NO AFFILIATION TO THE SITE ENTERED UNNOTICED BY SECURITY/ PERSONNEL PRIOR TO CREATING AN ALLEGED INJURY INCIDENT ON THE
#39556781Z
Nov 17, 2026
PENDING
$5,000
Jul 17, 2026Construction CLASS - 1
IN RESPONSE TO AMBULANCE BEING CALLED TO THE SITE ON JULY 10TH 2026 REVIEW OF CS LOG BOOK CONFIRMS THAT 2 UNAUTHORIZED PERSONS ENTERED THE SITE SAT DOWN, CALLED, AND LEFT IN AN AMBULANCE. GC DID NOT IMMEDIATELY
#39556780R
Nov 17, 2026
$5,000
Jun 10, 2026Construction CLASS - 2
FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33.-AS NOTED AT TIME OF INSPECTION OF AN ACTIVE JOB-SITE OF 8 STORY NEWBUILDING AT BULKHEAD LEVEL(COMPLETED), I OBSERVED THE CONCRETE SHEAR W
#35729982M
Nov 24, 2026
PENDING
$1,250
Jun 9, 2026Construction CLASS - 2
PROPOSED 8 STORY NEW BUILDING. OBSERVED ERECTED SUPPORTED PIPE SCAFFOLD ON TOP OF SIDEWALK SHED AT EXP#1, WHEN REQUESTED FOR LOAD IMPOSED LETTER AS REQUIRED BY 3314.3.4 AND INSTALLATION INSPECTION LETTER AS REQ
#39555269P
Nov 24, 2026
PENDING
$1,250
Apr 6, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED: STANDPIPE ALARM IN PLACE AT GROUND LEVEL IN A PROPOSED 8 STORY NEW BUILDING TOP OFF. UPON REVIEWING DEPARTMENT RECORDS IT APPEARED NO ELECTRICAL PERMIT FOR STANDPIPE ALARM SYSTEM
#39552653X
Mar 16, 2027
$1,250
Apr 6, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED: INADEQUATE STORAGE ZONE EXPO# 1 CONTAINER DEBRIS LOADED IN PROGRESS WITHOUT PROPER ENCLOSURE NO 4' CONTINUES BARRIER AND WIRE SCREEN THE SPACE BETWEEN THE BARRIER AND DECK OF SID
#39552654H
Mar 16, 2027
$2,400
Apr 6, 2026Unknown CLASS - 2
3303.12: ELEVATORS AND HOISTS DURING CONSTRUCTION OR DEMOLITION. AT TIME OF INSPECTION OBSERVED: PROPOSED 8 STORY NB TOP OFF 85' APPROX. CCD1 ELEVATOR IN READINESS NOT IN COMPLIANCE WITH ALL 14 STIPULATIONS, CR
#39552656L
Mar 16, 2027
PENDING
$2,500
Apr 6, 2026Unknown CLASS - 2
AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED AT EXPOSURE 1 NO MIRRORS AT LOCATIONS WHERE PEDESTRIANS VIEW IS OBSTRUCTED BY WOOD COLUMNS AT SIDEWALK AREA CONTRARY TO BC 3307.2.6. NUMERAL 3 CREATING A POTENTIAL
#39552655J
Mar 16, 2027
$2,500
Apr 6, 2026Unknown CLASS - 1
BC 3303.2.1 EXISTING SERVICES. AT TIME OF INSPECTION OBSERVED: POWER LINE INADEQUATE/NO PROTECTION AT EXPOSURE# TOUCHING SUPPORTED SCAFFOLD, WIRES EXPOSED, NOT PROTECTED, CREATING A POTENTIAL ELECTRICAL SHOCK C
#39552651M
Mar 16, 2027
$5,000
Apr 6, 2026Unknown CLASS - 2
3314.4.8 MAINTENANCE. AT TIME OF INSPECTION OBSERVED: SUPPORTED SCAFFOLD CONTRARY TO CODE INSTALLED AT EXPOSURE# 1-3. MISSING SECTIONS OF GUARDRAILS, LOOSE PLANKS, CREATING UNSAFE CONDITION. STOP ALL USE SUPPOR
#39552652Y
Mar 16, 2027
$2,500
Mar 18, 2026Construction CLASS - 1
3305.3.6.1.2 FAILURE TO SECURE RESHORES IN PROXLIMITY TO ENCLOSED PERIMETERS AS NOTED:AT TIME OF INSPECTION ON AN ACTIVE JOBSITE FOR A PROPOSED 8 STORY BUILDING OBSERVED AT CONCRETE DECK ON FLOOR#5 AT EXPOSURE
#35726573H
Apr 8, 2027
DEFAULT
$2,530
Mar 18, 2026Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENT.AS NOTED:AT TIME OF INSPECTION AT AN ACTIVE JOBSITE FOR A PROPOSED 8 STORYCONCRETE BUILDING OBSERVED CONCRETE WASHOUT WATER AND CONCRETE REMNANT
#35726450H
Apr 8, 2027
DEFAULT
$2,530
Jan 21, 2026Unknown CLASS - 2
PROPOSED 8 STORY BUILDING. ACTIVE CONCRETE OPERATIONS OBSERVED PORTABLE FUEL FIRE HEATERS AT 2FL. WHEN REQUESTED FOR FDNY PERMIT & CERTIFICATE OF FITNESS S92&S93 NONE WERE PROVIDED. TEMPORARY LADDER WITHOUT NON
#39549375H
Nov 23, 2026
PENDING
$0
Jan 21, 2026Construction CLASS - 2
PROPOSED 8 STORY BUILDING. OBSERVED ACTIVE CONCRETE OPERATIONS WITH MIXER AND CONCRETE PUMP TRUCK ON STREET WITHOUT ANY BARRIERS. UPON REVIEWING THE SITE SAFETY PLANS IT SHOWS FULLY ENCLOSED INTERLOCKED JERSEY
#39549379P
Nov 23, 2026
$1,250
Dec 20, 2025Construction CLASS - 2
AT THE TIME OF MY INSPECTION OBSERVED PEDESTRIAN WALKWAY ON STREET NOT MAINTAINED/INSTALLED PER CODE-JERSEY BARRIERS NOT FULLY INSTALLED(SPACING BETWEEN BARRIERS),NOT CONNECTED TOGETHER,NOT FILLED OUT WITH WATE
#39548197J
Dec 31, 2026
DEFAULT
$2,430
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 17, 2026ECBConstruction: PROPOSED 8 STORY NEW BUILDING. OBSERVED ERECTED SIDEWALK SHED WITH POSTED PERMIT NUMBER Q01223259-I1-SH EXPIRED AT 09/08/2026 UPON REQUEST FOR NEW PERMIT NON WAS PROVIDED AND AFTER FURTHER REVIEW ON DOB NOW NOOpen
Aug 3, 2026ECBConstruction: OBSERVED ACTIVE 8 STORY NB WITH SWS & SUPPORTED SCAFFOLD INSTALLED @ EXPO 1. SUPPORTED SCAFF IS ALSO INSTALLED ON EXPO 3. UPON REQUEST OF INITIAL INSTALLATION LETTER FOR SUPPORTED SCAFFOLD & SWS, NO LETTERS WEROpen
Aug 3, 2026ECBUnknown: 3301.1.2: OBSERVED ACTIVE 8 STORY NB WITH SWS AND SUPPORTED SCAFFOLD INSTALLED ON EXPO 1. MAIN STANDPIPE INSTALLED THROUGHOUT EVERY FLOOR AND HAS BEEN PAINTED RED. UPON REQUEST OF HYDROSTATIC PRESSURE TEST, NOClosed
Jul 17, 2026ECBConstruction: DURING INSPECTION IN REGARDS TO INCIDENT THAT TOOK PLACE WHERE 2 UNAUTHORIZED PERSONS WITH NO AFFILIATION TO THE SITE ENTERED UNNOTICED BY SECURITY/ PERSONNEL PRIOR TO CREATING AN ALLEGED INJURY INCIDENT ON THEOpen
Jul 17, 2026ECBConstruction: IN RESPONSE TO AMBULANCE BEING CALLED TO THE SITE ON JULY 10TH 2026 REVIEW OF CS LOG BOOK CONFIRMS THAT 2 UNAUTHORIZED PERSONS ENTERED THE SITE SAT DOWN, CALLED, AND LEFT IN AN AMBULANCE. GC DID NOT IMMEDIATELYClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 12:03 AM ET. BBL 4005020023.

Look up another building