Brooklyn · Block 1250 · Lot 40 · 11213

1093 St Johns Place

8 floors · 144 apartments · 123,741 sq ft · built 2009 · class D7 · owner of record: Crown Heights Apartments Llc

28open violations
$2,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 123,741 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $1,835,950 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2028
in 483 days
No Cycle 10 report on record yet
Energy audit and retro-commissioning (2030) Likely applies
Local Law 87 · Calendar year 2030
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1250). Agency page

Dec 31, 2030
in 1527 days
Next due 2030
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-07 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (5) · $2,500 owed
IssuedViolationHearingBalance
Jul 30, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION. OBSERVED SIDEWALK SHED IN PLACE INSTALLED AT EXP#1 & 4, BUT NO SHED PARAPET INFORMATION PANEL WAS PROVIDED AS REQUIRED BY THE BC. THIS CONDITION CREATES A HAZARDOUS CONDITION BY CAUSI
#39557267K
Oct 7, 2026
IN VIOLATION
$1,250
Mar 22, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES. AT TIME OF INSPECTION, I OBSERVED CRACKED CORNICES(ROOF TOP) AT EXPOSURE(1) SOUTH ELEVATION(WEST SIDE) AND STEP CRACKS(AT EAST END CORNER) AT EXPOSURE(1) SO
#35682272M
Oct 15, 2024
IN VIOLATION
$0
Feb 1, 2024Construction CLASS - 1
FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES SUCH AS SHED,NETTING,ETC WHERE REQUIRED TO PROTECT PUBLIC AND PROPERTY FROM DOCUMENTED UNSAFE FACADE AS PER 1RCNY 103-04.FISP 3 NOTIFICATION REPORT FILED AS UNSAFE-91
#35679691J
Nov 25, 2024
IN VIOLATION
$0
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#814747.AGG1:PRIOR NOV 37022323M UNDER 28-302.5
#37026142L
Nov 25, 2024
IN VIOLATION
$0
Oct 8, 2021Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#814747. REMEDY: FILE ACCEPTABLE REPORT.
#37022323M
May 11, 2022
IN VIOLATION
$1,250
DOB (5)
IssuedViolationStatus
Apr 3, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00144
DOB VIOLATION - ACTIVE
Feb 1, 2024CONSTRUCTION
EMERG WORK ORD DUE TO CRACKED FACADE MASONRY BRICKS AND CORNICE AT MULTIPLE LOCA IN EXP 1 (S.ELEV) AND EXP 4 (EAST ELE)THERE WAS NO SAFET Y MEASURERS AT ABOVE MENTIONED EXP 1 (SOUTH) & END EXP4 (E. ELEV) REMEDY:PROVIDE ADEQUATE SAFETY MEASURES AND REPAIR UNSAFE FACADE AT EX P 1 (S ELEV) & EXP (E ELE
#FA30801AE
DOB VIOLATION - ACTIVE
Feb 22, 2023NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
#00982
DOB VIOLATION - ACTIVE
Aug 30, 2018FACADE SAFETY PROGRAM

#HAZ87570
DOB VIOLATION - ACTIVE
Oct 1, 2012ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST
#02561
DOB VIOLATION - ACTIVE
DOB NOW Safety (18)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Aug 29, 2025Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Report
Active
Aug 29, 2025Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Report
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Apr 3, 2024AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
Feb 22, 2023Facades FISPNRF
CYCLE 9B NO REPORT FILED
Active
Aug 30, 2018Facades FISP
CYCLE 8B UNSAFE REPORT FILED
Active
Jul 31, 2018Facades FISPNRF
FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018
Active
Oct 1, 2012Elevators EVCAT1
Active
Oct 1, 2012Elevators EVCAT1
Active
Oct 1, 2012Elevators EVCAT1
Active
Oct 1, 2012Elevators EVCAT1
Active
Oct 1, 2012Elevators EVCAT1
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen
Jul 30, 2026ECBConstruction: AT THE TIME OF INSPECTION. OBSERVED SIDEWALK SHED IN PLACE INSTALLED AT EXP#1 & 4, BUT NO SHED PARAPET INFORMATION PANEL WAS PROVIDED AS REQUIRED BY THE BC. THIS CONDITION CREATES A HAZARDOUS CONDITION BY CAUSIOpen
Jul 1, 2026HPD B§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SHOWERSTALL IN THE BATHROOM LOCATED AT APT 8V, 8th STORY, 5th APARTMENT FROM EAST AT SOUTHClosed