Brooklyn · Block 1586 · Lot 8 · 11206

1090 Myrtle Avenue

7 floors · 41,212 sq ft · built 2018 · class H3 · owner of record: American Dream Ii Hotel Llc

12open violations
$8,125ECB/OATH penalties owed
0HPD class C (immediately hazardous)
116dto Facade inspection report (Cycle 10A)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 116 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 41,212 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 185 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 185 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 795 days
Next cycle year 2028

Open violations

ECB / OATH (2) · $8,125 owed
IssuedViolationHearingBalance
Jul 22, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION OBSERVED AT EXPOSURE 3(SOUTH) DISPLACED OR BRICKS THAT APPEAR TO HAVE MOVEMENT. REMEDY: PROVIDE ADEQUATE SAFETY MEASUR
#35731040L
Nov 25, 2026
PENDING
$5,000
Apr 6, 2026Elevators CLASS - 2
CLASS 2: ELEVATOR DEVICE INSTALLED IN 2020 HAS NOT UNDERGONE THE REQUIRED CATEGORY 5 FULL LOAD SAFETY TEST SINCE INSTALLATION, IN VIOLATION OF PERIODIC INSPECTION AND TESTING REQUIREMENTS. REMEDY: PERFORM A CAT
#39183329N
Jun 10, 2026
DEFAULT
$3,125
DOB (4)
IssuedViolationStatus
May 21, 2026CONSTRUCTION
STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION OBSERVED AT EXPO#4 A SECTION OF MASONRY BRICK VENEER HAS DISLODGED ALONG WITH VERTICAL CRACK AT EXPOSURE#1/4, DAMAGED WINDOWS AT 3RD, 4TH FLOOR DUE TO FIRE AT ADJOINING PROPERTY 1086 MYRTLE AVENUE.
#26-01359
DOB VIOLATION - ACTIVE
May 21, 2026CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT EXPOSURE#4 A SECTION APPROXIMATELY 4'X3' OF BRICK VENEER HAS DISLODGED ALONG WITH A 3' VERTICAL CRACK AT EXPOSURE#1/4 DUE TO FIRE AT ADJOINING PROPERTY 1086.
#26-01358
DOB VIOLATION - ACTIVE
Sep 21, 2021ELEVATOR

#9027/709003
DOB VIOLATION - ACTIVE
Sep 21, 2021ELEVATOR

#9027/709004
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Sep 25, 2026Benchmarking - LL84 DQ-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Sep 23, 2026Parking Structures FTF-PS-INITL
Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 25, 2026DOB SafetyBenchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4Open
Sep 23, 2026DOB SafetyParking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13Open
Jul 22, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION OBSERVED AT EXPOSURE 3(SOUTH) DISPLACED OR BRICKS THAT APPEAR TO HAVE MOVEMENT. REMEDY: PROVIDE ADEQUATE SAFETY MEASUROpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 7:47 AM ET. BBL 3015860008.